Norihiro Doda

Dr. Norihiro Doda

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2023 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
EHErina Hamase
Erina Hamase
KOKazuya Ohgama
Kazuya Ohgama
TKTakumi Kawamura
Takumi Kawamura
NDNorihiro Doda
Norihiro Doda
MTMasaaki Tanaka
Masaaki Tanaka
HYHidemasa Yamano
Hidemasa Yamano

15 March 2019 in Journal of Nuclear Engineering and Radiation Science
Verified
Journal Article
Closed access
PDF file
NKNorihiro Kikuchi
Norihiro Kikuchi
YIYasutomo Imai
Yasutomo Imai
RYRyuji Yoshikawa
Ryuji Yoshikawa
NDNorihiro Doda
Norihiro Doda
MTMasaaki Tanaka
Masaaki Tanaka
HOHiroyuki Ohshima
Hiroyuki Ohshima
In the design study of advanced loop-type sodium-cooled fast reactor in Japan, a specific fuel assembly (FA) called FA with inner duct structure (FAIDUS) is expected to enhance reactor safety during a core-disruptive accident. Evaluating the thermal-hydraulics in FAIDUS under various operating conditions is required for its design. This study is the first step toward confirming the design feasibility of FAIDUS; the thermal-hydraulics in FAIDUS are investigated with an in-house subchannel analysis code called asymmetrical flow in reactor elements (ASFRE), which can be applied to a wire-wrapped fuel pin bundle in conjunction with the distributed resistance model (DRM) and the turbulence-mixing model of the Todreas–Turi correlation model (TTM). Before simulating the thermal-hydraulics in FAIDUS, a few validations of DRM and TTM are conducted by comparing the numerical results of the pressure drop coefficients or temperature distribution obtained using ASFRE with the experimental data obtained using an apparatus with water or sodium for simulated FAs. After these validations, thermal-hydraulic analyses of FAIDUS and a typical FA are conducted for comparison. The numerical results indicate that, at a high flow rate simulating rated operation condition, no significant asymmetric temperature and velocity distribution occur in FAIDUS compared to the distribution in the typical FA. In addition, at a low flow rate simulating natural circulation condition in decay heat removal, the temperature distribution in FAIDUS is similar to that in the typical FA. This is because the local flow acceleration and the flow redistribution due to buoyancy force may occur in FAIDUS and the typical FA.

6 December 2024 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
EHErina Hamase
Erina Hamase
YMYasuhiro Miyake
Yasuhiro Miyake
YIYasutomo Imai
Yasutomo Imai
NDNorihiro Doda
Norihiro Doda
AOAyako Ono
Ayako Ono
MTMasaaki Tanaka
Masaaki Tanaka

24 May 2023 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
NDNorihiro Doda
Norihiro Doda
KIKenichi Igawa
Kenichi Igawa
TITakashi Iwasaki
Takashi Iwasaki
SMSatoshi Murakami
Satoshi Murakami
MTMasaaki Tanaka
Masaaki Tanaka

8 February 2023 in Journal of Nuclear Engineering and Radiation Science
Verified
Journal Article
Closed access
PDF file
NKNorihiro Kikuchi
Norihiro Kikuchi
YIYasutomo Imai
Yasutomo Imai
RYRyuji Yoshikawa
Ryuji Yoshikawa
NDNorihiro Doda
Norihiro Doda
MTMasaaki Tanaka
Masaaki Tanaka
In the design study of an advanced sodium-cooled fast reactor (advanced-SFR) in Japan Atomic Energy Agency (JAEA), the use of a specific fuel assembly (FA) with an inner duct structure called fuel assembly with an inner duct structure (FAIDUS) has been investigated to enhance safety of Advanced-SFR. Due to the asymmetric layout of fuel rods by the inner duct, it is necessary to estimate the coolant temperature distribution to confirm feasibility of FAIDUS. In JAEA, an in-house subchannel analysis code named thermal-hydraulic analysis of asymmetrical flow in reactor elements (ASFRE) has been developed as a FA design tool. For the typical FAs, the numerical results of ASFRE had been validated by comparisons with experimental data, in the previous study. As for the FAIDUS, confirmation of validity of the numerical results by ASFRE was not enough because the reference data on the thermal hydraulics in FAIDUS have not been obtained by the mockup experiment, yet. In this paper, therefore, the code-to-code comparisons with numerical results of ASFRE and those of an in-house computational fluid dynamics (CFD) code named single-phase thermal-hydraulic analysis in an irregular rod array layout (SPIRAL) were applied to make further discussion on applicability of ASFRE to the thermal hydraulics analysis in FAIDUS. Thermal hydraulic analyses of a typical FA and FAIDUS at high and low flowrate conditions were conducted. The applicability of ASFRE was indicated through the confirmation of the consistency of mechanism on appearance of the specific temperature distributions between the numerical results by ASFRE and those by SPIRAL. In addition, the necessity of modification on the empirical constants in numerical model of ASFRE to improve the predictive accuracy was indicated.

4 August 2025 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
KKKazuki Kuwagaki
Kazuki Kuwagaki
EHErina Hamase
Erina Hamase
KYKenji Yokoyama
Kenji Yokoyama
NDNorihiro Doda
Norihiro Doda
MTMasaaki Tanaka
Masaaki Tanaka