Ahmad Rezaei

Mr. Ahmad Rezaei


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMohsen Gholami
Mohsen Gholami
ARAhmad Rezaei
Ahmad Rezaei
TCTyler J. Cuthbert
Tyler J. Cuthbert
CNChristopher Napier
Christopher Napier
Carlo MenonCarlo Menon
Carlo Menon
Continuous kinematic monitoring of runners is crucial to inform runners of inappropriate running habits. Motion capture systems are the gold standard for gait analysis, but they are spatially limited to laboratories. Recently, wearable sensors have gained attention as an unobtrusive method to analyze performance metrics and the health conditions of runners. In this study, we developed a system capable of estimating joint angles in sagittal, frontal, and transverse planes during running. A prototype with fiber strain sensors was fabricated. The positions of the sensors on the pelvis were optimized using a genetic algorithm. A cohort of ten people completed 15 min of running at five different speeds for gait analysis by our prototype device. The joint angles were estimated by a deep convolutional neural network in inter- and intra-participant scenarios. In intra-participant tests, root mean square error (RMSE) and normalized root mean square error (NRMSE) of less than 2.2° and 5.3%, respectively, were obtained for hip, knee, and ankle joints in sagittal, frontal, and transverse planes. The RMSE and NRMSE in inter-participant tests were less than 6.4° and 10%, respectively, in the sagittal plane. The accuracy of this device and methodology could yield potential applications as a soft wearable device for gait monitoring of runners.

3 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ARAhmad Rezaei
Ahmad Rezaei
TCTyler J. Cuthbert
Tyler J. Cuthbert
MGMohsen Gholami
Mohsen Gholami
Carlo MenonCarlo Menon
Carlo Menon
Wearable electronics are recognized as a vital tool for gathering in situ kinematic information of human body movements. In this paper, we describe the production of a core–sheath fiber strain sensor from readily available materials in a one-step dip-coating process, and demonstrate the development of a smart sleeveless shirt for measuring the kinematic angles of the trunk relative to the pelvis in complicated three-dimensional movements. The sensor’s piezoresistive properties and characteristics were studied with respect to the type of core material used. Sensor performance was optimized by straining above the intended working region to increase the consistency and accuracy of the piezoresistive sensor. The accuracy of the sensor when tracking random movements was tested using a rigorous 4-h random wave pattern to mimic what would be required for satisfactory use in prototype devices. By processing the raw signal with a machine learning algorithm, we were able to track a strain of random wave patterns to a normalized root mean square error of 1.6%, highlighting the consistency and reproducible behavior of the relatively simple sensor. Then, we evaluated the performance of these sensors in a prototype motion capture shirt, in a study with 12 participants performing a set of eight different types of uniaxial and multiaxial movements. A machine learning random forest regressor model estimated the trunk flexion, lateral bending, and rotation angles with errors of 4.26°, 3.53°, and 3.44° respectively. These results demonstrate the feasibility of using smart textiles for capturing complicated movements and a solution for the real-time monitoring of daily activities.

23 June 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
ARAhmad Rezaei
Ahmad Rezaei
MKMahta Khoshnam
Mahta Khoshnam
Carlo MenonCarlo Menon
Carlo Menon
Developing wearable platforms for unconstrained monitoring of limb movements has been an active recent topic of research due to potential applications such as clinical and athletic performance evaluation. However, practicality of these platforms might be affected by the dynamic and complexity of movements as well as characteristics of the surrounding environment. This paper addresses such issues by proposing a novel method for obtaining kinematic information of joints using a custom-designed wearable platform. The proposed method uses data from two gyroscopes and an array of textile stretch sensors to accurately track three-dimensional movements, including extension, flexion, and rotation, of a joint. More specifically, gyroscopes provide angular velocity data of two sides of a joint, while their relative orientation is estimated by a machine learning algorithm. An unscented Kalman filter (UKF) algorithm is applied to directly fuse angular velocity/relative orientation data and estimate the kinematic orientation of the joint. Experimental evaluations were carried out using data from 10 volunteers performing a series of predefined as well as unconstrained random three-dimensional trunk movements. Results show that the proposed sensor setup and the UKF-based data fusion algorithm can accurately estimate the orientation of the trunk relative to pelvis with an average error of less than 1.72 degrees in predefined movements and a comparable accuracy of 3.00 degrees in random movements. Moreover, the proposed platform is easy to setup, does not restrict body motion, and is not affected by environmental disturbances. This study is a further step towards developing user-friendly wearable sensor systems than can be readily used in indoor and outdoor settings without requiring bulky equipment or a tedious calibration phase.