It is well-known that wireless communication technologies facilitate human life. However, the harmful effects of electromagnetic field (EMF) radiation on the human body should not be ignored. In the present study, we evaluated the effects of long-term, prenatal exposure to EMF radiation on the myocardium of rats at varying durations. Overall, 18 pregnant Sprague-Dawley rats were assigned into six groups ( n = 3 in each group). In all groups other than the control group, three pregnant rats were exposed to EMF radiation (900, 1800 and 2100 MHz) for 6, 12 and 24 h over 20 days. After delivery, the newborn male pups were identified and six newborn male pups from each group were randomly selected. Then, histopathological and biochemical analysis of myocardial samples were performed. When 24-h/day prenatal exposures to 900, 1800, 2100 MHz EMF radiation were evaluated, myocardial damage was greater in the 2100 MHz EMF-24h group than the other groups. In addition, when malondialdehyde (MDA) and glutathione (GSH) levels associated with reactive oxidative species (ROS) were evaluated, the MDA level was higher in the 2100 MHz EMF-24h group compared with the other groups. The GSH level was also lower in the 2100 MHz EMF-24h group. When the 6, 12 and 24 h/day prenatal exposures to 1800 MHz EMF radiation were evaluated, myocardial damage was greater in 1800 MHz EMF-24h group than the remaining groups ( p < 0.0001). Also, MDA level was greater in the 1800 MHz EMF-24h group compared with the other groups while the GSH level was lower in this group. It was shown that myocardial tissue was affected more by long-term exposure to EMF radiation at high frequencies. The data raise concerns that the harmful effects of non-ionizing radiation exposure on cardiac tissue will increase with 5G technology.
Testicular ischaemia reperfusion (I/R) injury results with serious dysfunctions in testis. This study aims to explore effects of soluble guanylate cyclase (sGC) stimulator Riociguat on experimental testicular I/R injury in rats. Twenty-one male rats were divided into three groups (Control, IR and IRR). The control group was not exposed to any application. Bilateral testis from IR and IRR animals were rotated 720° in opposite directions for 3 h to induce experimental testicular ischaemia. Animals in IR and IRR groups were subjected to 3 h of reperfusion. Isotonic and Riociguat were administered to the animals 30 min prior reperfusion by oral gavage. At the end of experiment, animals were sacrificed and tissue samples were used for analyses. Riociguat treatment significantly decreased tissue malondialdehyde and Luminol levels compared to the IR group (p < 0.05). The pathological changes, pro-apoptotic proteins (Bax, Caspase 3, and Caspase 9) and apoptotic index in the IR group were down regulated in Riociguat treated animals (p < 0.05). Riociguat treatment was also significantly increased anti-apoptotic Bcl-2 expression, but alleviated tissue injury via modulating pro-inflammatory cytokine IL-1β levels and significantly (p < 0.05) down-regulating NF-κB activity. Moreover, mTOR and ERK phosphorylation increased in IR group (p < 0.05), but Riociguat treatment reduced protein phosphorylation. Our experiment indicated that targeting sGC might support surgical interventions in testicular I/R injury by modulating oxidative stress, inflammation, and apoptotic protein expression levels, but more detailed studies are required to explore the protective activity of Riociguat and underlying mechanisms in testicular I/R injury.
Background and Aim: This study examined the effects of black cumin seed oil treatment on oxidative stress and the expression of radixin and moesin in the liver of experimental diabetic rats. Materials and Methods: Eighteen rats were divided into 3 equal groups (control, diabetes, treatment). The control group was not exposed to any experimental treatment. Streptozotocin was administered to the rats in the diabetes and treatment groups. A 2.5 mL/kg dose of black cumin seed oil was administered daily for 56 days to the treatment group. At the conclusion of the experiment, the blood level of malondialdehyde (MDA) and glutathione (GSH) was measured. The expression level and the cellular distribution of radixin and moesin in the liver were analyzed. Results: The plasma MDA (3.05±0.45 nmol/mL) and GSH (78.49±20.45 μmol/L) levels in the diabetes group were significantly different (p0.05) and moesin expression was significantly downregulated (p
Background and Aim: In this study, we aimed to assess the hemostatic and histopathological impacts of the Algan hemostatic agent (AHA) with the liver injury model. Materials and Methods: 24 male rats, 10-12 week old, were randomly divided into three equal groups (n=8) as control (physiological saline solution), AHA liquid and AHA powder. A total of three iatrogenic cut injuries were performed on the anterior surface of the left liver lobe. After bleeding started, sponges soaked with physiological saline, AHA liquid, AHA powder were gently pressed on the injured area for 20 seconds in corresponding groups, respectively. The bleeding time was measured with a timer. Failure to stop bleeding after three consecutive applications was considered as a failure. Animals were euthanized at the tenth minute of the procedure. Left liver lobes were removed for histopathological examination. Results: Bleeding control success rates of AHA liquid were significantly higher than that of the AHA powder group, and both forms were more effective than physiological saline. A superficial thick granulation tissue with entrapped powder residual materials was detected in the AHA powder group. Liver parenchyma was intact in liquid and powder groups. Conclusion: AHA is a fast-acting and applicable hemostatic agent in the liver bleeding model. However, further comparative studies in various organs are needed.
27 April 2023 in Harran Üniversitesi Tıp Fakültesi Dergisi
Background: The aim of this study is to evaluate the acute hemostatic effects of liquid and powder forms of AHA in severe bleeding model of rat renal vein. Materials and Methods: 10-12 weeks old, 24 male Wistar albino rats were randomly divided into three groups of eight animals each as the control, AHA liquid, AHA powder. The left renal artery and vein were revealed with a 3 cm vertical incision and the tip of the injector was used to puncture renal vein, causing bleeding. In all animals, regular gauze patch was pressed over the incised area for 10 seconds as soon as the bleeding began. Immediately after removing the sponge; physiological saline, AHA liquid and powder were applied with compress to injured site of relevant groups for 2 minutes, respectively. The time was recorded by chronometer and the area was checked after two minutes. Hemostasis that was not achieved after three applications was accepted as failure. Results: Cessation of the bleeding failed in all rats after three successive 2-minute physiological saline impregnated gauze applications in control group. Among AHA-treated groups, significant hemostasis efficacy was obtained from the liquid form than that of powder. Within first two minutes, bleeding in renal veins of five rats was controlled successfully in liquid group whereas powder group achieved hemostatic success in four rats. Conclusions: The vessel incision model in our study revealed fast-acting physical hemostatic properties of the liquid and powder formulations of AHA in the renal vein. This natural applicable product could be used to induce hemostasis in rat models of bleeding caused by various renal damages or trauma, and it could also prevent local bleeding in humans. More studies are needed to compare the efficacy of different formulations of the polysaccharide-based herbal product in various organs and surgical models.
Background/Aim: Nowadays, many deaths are related to vessel injury-induced blood loss. Failure to control bleeding also increases the risk of death. This study aimed to investigate the hemostatic effects of the Algan Hemostatic Agent (AHA) foam application in a rat model in which severe femoral artery bleeding was induced. Methods: Fourteen rats were randomly assigned to two groups: (1) control (physiological saline) (n = 7) and (2) AHA foam (n = 7). The left femoral artery of the rats was incised and when the bleeding started, and the area was pressed with another sponge for 10 s in all rats. Afterwards, physiological saline solution impregnated gauze or AHA foam was placed over same area. A chronometer was started and area was checked after 2 min. If no bleeding occurred during the first 2 min of application, it was recorded as “successful”. If bleeding occurred, the same procedure was repeated up to three times. If hemostasis could not be achieved even after the third application, it was considered a failure, and “failed” was recorded. All animals were sacrificed under high anesthesia for least 10 min after the experiment. Results: Application of AHA resulted in complete (100%) control of bleeding in all rats within the first 2 min. In control group, hemostasis was achieved in 1 out of 7 (14.3%) rats by the third application. Failure was recorded for the remaining six rats. The hemostatic success rate of the AHA foam was significantly higher than the rates of control group (P = 0.005). Conclusion: AHA foam is a very effective hemostatic agent and can be applied easily on vascular trauma models. Further studies are needed to elucidate hemostatic features of AHA.