Xuan Zhang

Dr. Xuan Zhang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SZshuyi zhang
shuyi zhang
DWDifeng Wang
Difeng Wang
FGFang Gong
Fang Gong
YXYuzhuang Xu
Yuzhuang Xu
XHXianqiang He
Xianqiang He
DFDongyang Fu
Dongyang Fu
Inaccuracies in the atmospheric correction (AC) of data on coastal waters significantly limit the ability to quantify the parameters of water quality. Many studies have compared the effects of the atmospheric correction of data provided by the Sentinel−2 satellites, but few have investigated this issue for coastal waters in China owing to a limited amount of in situ spectral data. The authors of this study compared four processors for the atmospheric correction of data provided by Sentinel−2—the Atmospheric Correction for OLI ‘lite’(ACOLITE), Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Data Analysis System (SeaDAS), Polynomial-based algorithm applied to MERIS (POLYMER), and Case 2 Regional Coast Colour (C2RCC)—to identify the most suitable one for water bodies with different turbidities along the coast of China. We tested the algorithms used in these processors for turbid waters and compared the resulting inversion of the remote sensing reflectance (Rrs) using in situ reflectance data from three stations with varying levels of coastal turbidity (HTYZ, DONG’OU, and MUPING). All processors significantly underestimated the results on data from the HTYZ station, which is located along waters with high turbidity, with the SeaDAS delivering the best performance, with an average band RMSE of 0.0146 and an average MAPE of 29.80%. It was followed by ACOLITE, with an average band RMSE of 0.0213 and an average MAPE of 43.43%. The performance of two AC algorithms used in ACOLITE, dark spectrum fitting (DSF) and exponential extrapolation (EXP), was also evaluated by comparing their results with in situ measurements at the HTYZ site. The ACOLITE-EXP algorithm delivered a slight improvement in results for the blue band compared with the DSF algorithm in highly turbid water, but led to no significant improvement in the green and red bands. C2RCC delivered the best performance on data from the DONG’OU station, which is located along water with medium turbidity, and from the MUPING station (water with low turbidity), with values of the MAPE of 18.58% and 28.41%, respectively.

7 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TPTianfeng Pan
Tianfeng Pan
XHXianqiang He
Xianqiang He
XZXuan Zhang
Xuan Zhang
JLJia Liu
Jia Liu
YBYan Bai
Yan Bai
TLTeng Li
Teng Li
Previous studies on the polarization imaging of underwater targets mainly focused on top-down detection; however, the capacities of bottom-up detection were poorly known. Based on in situ experiments, the capability of bottom-up detection of underwater targets using polarization imaging was investigated. First, to realize the objective of bottom-up polarization imaging, a SALSA polarization camera was integrated into our Underwater Polarization Imaging System (UPIS), which was integrated with an attitude sensor. At Qiandao Lake, where the water is relatively clear, experiments were conducted to examine the capacity of the UPIS to detect objects from the bottom up. Simultaneously, entropy, clarity, and contrast were adopted to compare the imaging performance with different radiation parameters. The results show that among all the used imaging parameters, the angle of polarization is the optimal parameter for bottom-up detection of underwater targets based on polarization imaging, which may result from the different diffused reflectance of the target surface to the linear polarization components of the Stokes vector.

2 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HZHaohui Zeng
Haohui Zeng
XHXianqiang He
Xianqiang He
YBYan Bai
Yan Bai
FGFang Gong
Fang Gong
DWDifeng Wang
Difeng Wang
XZXuan Zhang
Xuan Zhang
Acquiring a large number of in situ water spectral measurements is fundamental for constructing water color remote-sensing retrieval models and validating the accuracy of water color remote-sensing products. However, traditional manual site-based water spectral measurements are time-consuming and labor-intensive, resulting in an insufficient number of in situ water spectral samples to date. To resolve this issue, this study develops an unmanned aerial vehicle-based hyperspectral remote-sensing reflectance measurement system (UAV-RRS) capable of continuous on-the-move water spectral measurements. This paper provides a detailed introduction to the system components and conducts precise experiments on the correction and calibration of the spectral sensors. Using this system, an in situ–UAV–satellite multi-source remote-sensing reflectance comparison experiment was conducted in the middle reaches of the Qiantang River, East China, to evaluate the accuracy and reliability of UAV-RRS and extend the analysis to satellite data across different spatial scales. The results demonstrate that, in small-scale water bodies, UAV-RRS achieves higher spatial precision and spectral accuracy, offering a valuable solution for high-precision, low-altitude continuous water body observations.

15 November 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
YYYujia Yan
Yujia Yan
XHXianqiang He
Xianqiang He
YBYan Bai
Yan Bai
JLJinsong Liu
Jinsong Liu
PSPalanisamy Shanmugame
Palanisamy Shanmugame
FGFang Gong
Fang Gong
Real-time monitoring of riverine-dissolved organic carbon (DOC) and its controlling factors is critical for formulating strategies regarding the river basin and marginal seas pollution prevention and control. In this study, we established a linear regression formulation that relates the permanganate index (CODMn) to the DOC concentration based on in situ measurements collected on five field surveys in 2023–2024. This regression formulation was used on a large number of data collected from automatic monitoring stations in the Qiantang River area to construct a daily quasi-in situ database of DOC concentration. By combining the quasi-in situ DOC data and Sentinel-2 measurements, an enhanced algorithm for empirical DOC estimation was developed (R2 = 0.66) using the extreme gradient boosting (XGBoost) method and its spatial and temporal variations in the Qiantang River were analyzed from 2016 to 2023. Spatially, the main stream of the Qiantang River exhibited an overall decreasing and increasing trend influenced by population density, economic development, and pollutant discharge in the basin area, and the temporal distribution of DOC was controlled by meteorological conditions. The DOC contents had the highest in summer, primarily due to high rainfall and leaching. The inter-annual variation in DOC concentration was influenced by the total annual runoff volumes, with a minimum level of 2.24 mg L−1 in 2023 and a maximum level of 2.45 mg L−1 in 2019. The monthly DOC fluxes ranged from 6.3 to 13.8 × 104 t, with the highest values coinciding with the maximum river discharge volumes in June and July. The DOC levels in the Qiantang River remained relatively high in recent years (2016–2023). This study enables the concerned stakeholders and researchers to better understand carbon transportation and its dynamics in the Qiantang River and its coastal areas.

27 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
WGWei Gao
Wei Gao
XHXianqiang He
Xianqiang He
XZXuan Zhang
Xuan Zhang
XJXuchen Jin
Xuchen Jin
FGFang Gong
Fang Gong
Traditional approaches for monitoring aquatic organic carbon, such as satellite remote sensing and automated underwater sensors, are often constrained by limited temporal resolution, data gaps under cloudy conditions, maintenance requirements, and cost-effectiveness. To overcome these limitations, we developed and field-demonstrated a ground-based hyperspectral remote sensing system (GHRSS) for continuous, high-frequency monitoring of dissolved organic carbon (DOC) and particulate organic carbon (POC). The system is based on the above-water method and integrates three miniature hyperspectral spectrometers to measure water-surface radiance, sky radiance, and downwelling irradiance for deriving hyperspectral remote sensing reflectance (Rrs). The spectrometers cover 400–900 nm with a spectral resolution of 1 nm and support a minimum sampling interval of 10 s. The GHRSS also integrates solar power supply, 4G communication, and a microcomputer, enabling autonomous long-term deployment and wireless data transmission. Based on the GHRSS, retrieval models for DOC and POC were developed and validated using 90 paired in situ measurements collected from the Cao’e River. Empirical and machine learning methods were applied to retrieve DOC and POC from the measured Rrs data. The empirical models showed limited retrieval performance, whereas partial least squares regression (PLSR) and support vector regression (SVR) substantially improved model accuracy. Among all models, SVR achieved the best performance on the independent test set, with R2=0.979, RMSE = 0.031 mg/L, and MAE = 0.024 mg/L for DOC and R2=0.960, RMSE = 0.152 mg/L, and MAE = 0.066 mg/L for POC. Using the optimal SVR models, minute-scale time series of DOC and POC were reconstructed from the GHRSS observations. The results revealed pronounced sub-daily variability in both parameters, with DOC varying relatively smoothly, whereas POC exhibited stronger short-term fluctuations and more rapid responses to hydrodynamic changes. These findings demonstrate that the GHRSS, combined with machine learning models, provides an effective and practical approach for continuous, high-frequency monitoring of riverine organic carbon dynamics.