This paper comprises an updated version of the 2014 review which reported 1846 volatile organic compounds (VOCs) identified from healthy humans. In total over 900 additional VOCs have been reported since the 2014 review and the VOCs from semen have been added. The numbers of VOCs found in breath and the other bodily fluids are: blood 379, breath 1488, faeces 443, milk 290, saliva 549, semen 196, skin 623 and urine 444. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been included in a single table with the source reference(s) for each VOC, an update on our 2014 paper. VOCs have also been grouped into tables according to their chemical class or functionality to permit easy comparison. Careful use of the database is needed, as a number of the identified VOCs only have level 2—putative assignment, and only a small fraction of the reported VOCs have been validated by standards. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces and breath. However, the lack of compounds from matrices such a semen and milk compared to breath for example could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from milk and semen compared to a large number for breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. by collecting skin sebum (with dissolved VOCs and semi VOCs) onto glass beads or cotton pads and then heating to a high temperature to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors’ intention that this work will not only be a useful database of VOCs listed in the literature but will stimulate further study of VOCs from healthy individuals; for example more work is required to confirm the identification of these VOCs adhering to the principles outlined in the metabolomics standards initiative. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.
The assessment of volatile compounds (VOCs) for disease diagnosis is a growing area of research. There is a need to provide hard evidence i.e. biochemical routes, to justify putative VOC biomarkers, as in many cases this remains uncertain, which weakens their authenticity. Recently reports of volatile hydrocarbons and or aldehydes in bodily fluids and breath have been attributed to oxidative stress, although as discussed here, fewer compounds have been reported than expected from a mechanistic examination. Oxidative stress can result from many disease states which produce inflammation, and a better understanding of the interconnection between oxidative stress and the release of VOCs from target diseased and healthy organs could greatly help diagnoses. It is generally considered that oxidation of unsaturated fatty acids are a major source of these VOCs. An investigation listing the many possible volatile oxidation products has not been undertaken. This is described here using a mechanistic analysis (based on the literature) of the compounds derived from molecular cleavage and the results compared with a recent review of all the VOCs emanating from the human body, which satisfactorily explains the presence of at least 100 VOCs. Six important unsaturated fatty acids, oleic, palmitoleic, linoleic, linolenic, arachidonic, and cervonic acids have been shown to be capable of producing up to 18 n+6 unique breakdown products (where n = the number of alkene double bonds in the fatty acid hydrocarbon chain), in total 299 compounds. In many cases these have not been reported. We suggest several reasons for this: these VOCs have not been expected, so researchers are not looking for them and importantly some are not present in the mass spectral libraries, or they are too low a concentration to have been detected, or are not present. Furthermore a theoretical explanation for the origins of branched aldehydes and other compounds arising from bacterial oxidative metabolism of unsaturated fatty acids are described.
The COVID-19 pandemic has highlighted the importance of rapid, cost effective, accurate, and non-invasive testing for viral infections. Volatile compounds (VCs) have been suggested for several decades as fulfilling these criteria. However currently very little work has been done in trying to diagnose viral infections using VCs. Much of the work carried out to date involves the differentiation of bacterial and viral sources of infection and often the detection of bacterial and viral co-infection. However, this has usually been done in vitro and very little work has involved the use of human participants. Viruses hijack the host cell metabolism and do not produce their own metabolites so identifying virus specific VCs is at best a challenging task. However, there are proteins and lipids that are potential candidates as markers of viral infection. The current understanding is that host cell glycolysis is upregulated under viral infection to increase the available energy for viral replication. There is some evidence that viral infection leads to the increase of production of fatty acids, alkanes, and alkanes related products. For instance, 2,3-butandione, aldehydes, 2,8-dimethyl-undecane and n-propyl acetate have all been correlated with viral infection. Currently, the literature points to markers of oxidative stress (e.g. nitric oxide, aldehydes etc) being the most useful in the determination of viral infection. The issue, however, is that there are also many other conditions that can lead to oxidative stress markers being produced. In this review a range of (mainly mass spectrometric) methods are discussed for viral detection in breath, including breath condensate. Currently MALDI-ToF-MS is likely to be the preferred method for the identification of viral strains and variants of those strains, however it is limited by its need for the viral strains to have been sequenced and logged in a database.
The investigation of novel sample matrices in the forensic sciences offers several possible advantages, such as allowing for results to be obtained in cases where common sample types are absent. This review focuses on the application of gas chromatography and gas chromatography–mass spectrometry (GC-MS) for the determination of drugs in alternative sample matrices, including hair, sweat, meconium, breast milk, and vitreous humour. Less common sample types are also reported including air, cerumen, insects, and their larvae and pupae. The application of pyrolysis GC-MS (Py GC-MS) is also reviewed, showing the possibility of determining high molecular weight drugs which would commonly be unattainable by GC-MS. The application of Py GC-MS for the simulation and investigation of the underlying chemistry and the products formed in the smoking of drugs is also reported.
Mass spectrometry (MS) is an analytical technique that can be used for various applications in a number of scientific areas including environmental, security, forensic science, space exploration, agri-food, and numerous others. MS is also continuing to offer new insights into the proteomic and metabolomic fields. MS techniques are frequently used for the analysis of volatile compounds (VCs). The detection of VCs from human samples has the potential to aid in the diagnosis of diseases, in monitoring drug metabolites, and in providing insight into metabolic processes. The broad usage of MS has resulted in numerous variations of the technique being developed over the years, which can be divided into hyphenated and real-time MS techniques. Hyphenated chromatographic techniques coupled with MS offer unparalleled qualitative analysis and high accuracy and sensitivity, even when analysing complex matrices (breath, urine, stool, etc.). However, these benefits are traded for a significantly longer analysis time and a greater need for sample preparation and method development. On the other hand, real-time MS techniques offer highly sensitive quantitative data. Additionally, real-time techniques can provide results in a matter of minutes or even seconds, without altering the sample in any way. However, real-time MS can only offer tentative qualitative data and suffers from molecular weight overlap in complex matrices. This review compares hyphenated and real-time MS methods and provides examples of applications for each technique for the detection of VCs from humans.
Colorectal symptoms are common but only infrequently represent serious pathology, including colorectal cancer (CRC). A large number of invasive tests are presently performed for reassurance. We investigated the feasibility of urinary volatile organic compound (VOC) testing as a potential triage tool in patients fast-tracked for assessment for possible CRC. A prospective, multi-center, observational feasibility study was performed across three sites. Patients referred to NHS fast-track pathways for potential CRC provided a urine sample that underwent Gas Chromatography-Mass Spectrometry (GC-MS), Field Asymmetric Ion Mobility Spectrometry (FAIMS), and Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) analysis. Patients underwent colonoscopy and/or CT colonography and were grouped as either CRC, adenomatous polyp(s), or controls to explore the diagnostic accuracy of VOC output data supported by an artificial neural network (ANN) model. 558 patients participated with 23 (4%) CRC diagnosed. 59% of colonoscopies and 86% of CT colonographies showed no abnormalities. Urinary VOC testing was feasible, acceptable to patients, and applicable within the clinical fast track pathway. GC-MS showed the highest clinical utility for CRC and polyp detection vs. controls (sensitivity = 0.878, specificity = 0.882, AUROC = 0.896) but it is labour intensive. Urinary VOC testing and analysis are feasible within NHS fast-track CRC pathways. Clinically meaningful differences between patients with cancer, polyps, or no pathology were identified suggesting VOC analysis may have future utility as a triage tool.