Anterior tibial translation was measured in both knees using the radiological Lachman test and the lateral monopodal stance tests in 281 patients with unilateral anterior cruciate ligament (ACL) rupture. Measurements of translation in the medial compartment were more useful than those in the lateral compartment. Measurement of anterior tibial translation in the medial compartment using the radiological Lachman test showed ACL rupture in 92% of cases compared with 70% for the lateral monopodal stance test. In normal and in ACL-ruptured knees the monopodal stance test showed that every 10 degrees increase in posterior inclination of the tibial plateau was associated with a 6 mm increase in anterior tibial translation; the radiological Lachman test showed a 3 mm increase for every 10 degrees increase in tibial slope.
1 July 2004 in Clinical Orthopaedics and Related Research
The Salto Total Ankle Prosthesis is noncemented with mobile bearings and is characterized by an anatomic design and a dual Ti-HA coating. Between 1997 and 2000, 98 consecutive Salto prostheses were implanted. At last followup, two patients were deceased, one patient was lost to followup, and two prostheses were removed in two patients. Ninety-three implants in 91 patients were available with a mean followup of 35 months (range, 24–68 months). Survivorship at 68 months, with the end point implant removal, then was 98% (favorable scenario) to 94.9% (unfavorable scenario). The American Orthopaedic Foot and Ankle Society score was 32.3 points preoperatively and 83.1 points at followup. Seventy-two patients are pain-free, 54 patients walk unlimited distances, and 25 patients have limitation but walk more than 1 km. Sixty-seven patients have no limp but seven need walking aids. Fifty-eight patients can walk on tiptoes, 49 patients can walk on uneven ground, 14 patients can run, 76 patients ascend stairs normally, and 63 patients descend stairs normally. Range of motion as measured on stress radiographs improved from 15.2° preoperatively to 28.3° at followup. Preliminary results of the Salto prosthesis are encouraging and validate the concept of anatomic replacement.
1 January 2011 in Clinical Orthopaedics and Related Research
The mobile-bearing Salto prosthesis has been used in Europe since 1997, but only 2 to 5 years of followup data have been reported. Questions/purposes We analyzed the longer-term survivorship and causes of failures of the Salto prosthesis in a cohort of previously studied patients. We asked whether this prosthesis provided a functional ankle (AOFAS score) and durable radiographic fixation. Patients and Methods We retrospectively reviewed 96 prospectively followed patients with 98 prostheses implanted between 1997 and 2000. Of those, 85 patients (87 prostheses) had a minimum followup of 6.8 years (mean, 8.9 years; range, 6.8-11.1 years). Results The survival rate was 65% (95% CI, 50-80) with any reoperation of the ankle and 85% (95% CI, 75-95) with revision of a component as the end points. Six prostheses were removed for arthrodesis, and 18 ankles underwent reoperation without arthrodesis. We observed three main causes of reoperations: bone cysts (11 patients), fracture of the polyethylene (five patients), and unexplained pain (three patients). The mean AOFAS score was 79 ± 12 points. Radiographic subsidence was observed in three patients and bone cysts in eight patients. Conclusions Our data suggest a high rate of reoperations but only six revisions with arthrodesis with mid-term followup. We observed few patients with loosening and/or subsidence. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....
20 May 2011 in Knee Surgery, Sports Traumatology, Arthroscopy
Purpose: Manufacturers of total knee arthroplasty (TKA) have introduced narrower femurs to improve bone‐implant fit. However, few studies have reported the clinical consequences of mediolateral oversizing. Our hypothesis was that component oversizing negatively influences the results after TKA.Methods: One hundred and twelve prospectively followed patients with 114 consecutive TKA (64 females and 50 males) were retrospectively assessed. The mean age of the patients was 72 years (range, 56 to 85 years). The dimensions of the femur and tibia were measured on a preoperative CT‐scan and were compared with those of the implanted TKA. The influence of size variation on the clinical outcomes 1 year after surgery was assessed.Results: Mediolateral overhang was observed in at least one area in 66 % of the femurs (84 % in females and 54 % in males) and 61 % of the tibia (81 % in females and 40 % in males). Twenty‐two patients presented no overhang in any area and 16 had overhang in all studied zones. The increase in the Pain and KOOS scores were 43 ± 21 and 36 ± 18 in the patients without overhang and 31 ± 19 and 25 ± 13 in patients with overhang (p = 0.033; p = 0.032). Knee flexion was 127° ± 7 and 121° ± 11, respectively. Regression and latent class analysis showed a significant negative correlation between overall oversizing and overall outcome.Conclusions: This study confirms that oversizing may lead to worse clinical results in TKA. The clinical consequences are that surgeons should pay attention not to oversize implants during implantation nd that oversizing should be ruled out in case of so called unexplained pain.Level of evidence: IV.
1 February 2012 in Orthopaedics & Traumatology: Surgery & Research