Melih Unal

Mr. Melih Unal


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2018 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
Ozkan KoseOzkan Kose
Ozkan Kose
ATAdil Turan
Adil Turan
MUMelih Unal
Melih Unal
BABaver Acar
Baver Acar
FGFerhat Guler
Ferhat Guler

2 August 2019 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
BABaver Acar
Baver Acar
Ozkan KoseOzkan Kose
Ozkan Kose
MUMelih Unal
Melih Unal
ATAdil Turan
Adil Turan
YKYusuf Alper Kati
Yusuf Alper Kati
FGFerhat Guler
Ferhat Guler

1 April 2018 in Cureus
Verified
Journal Article
Open access
PDF file
BABaver Acar
Baver Acar
MUMelih Unal
Melih Unal
ATAdil Turan
Adil Turan
Ozkan KoseOzkan Kose
Ozkan Kose
Magnesium (Mg) bioabsorbable screws are new biomaterials used in fracture fixation. In the current literature, there is only one case report on the use of magnesium bio-absorbable screws in ankle fractures. Within the present study, a 19-year-old female who sustained an isolated lateral malleolar fracture was treated with open reduction and intramedullary Mg screw fixation and then followed up for two years. Fracture union was achieved without any complication such as failure of fixation, loss of reduction, infection, or any other adverse reaction. Mg bioabsorbable screws are an alternative method of fracture fixation as compared to conventional metallic implants since they eliminate the need for implant removal.

19 January 2022
Verified
Journal Article
Open access
MUMelih Unal
Melih Unal
EDEngin Demirayak
Engin Demirayak
MEmehmet baris Ertan
mehmet baris Ertan
ÖKömer faruk Kılıçaslan
ömer faruk Kılıçaslan
Ozkan KoseOzkan Kose
Ozkan Kose
Metallic screws are commonly used to fix tibial tubercle osteotomies (TTO). However, hardware removal late after osteotomy union is one of the most common causes of reoperation following TTOs. The use of bioabsorbable screws may eliminate secondary surgeries, but there is no study on their use in this indication. The purpose of this retrospective study was to evaluate the safety and efficacy of bioabsorbable magnesium (Alloy: MgYREZr) screws in tibial tubercle osteotomy (TTO) fixation. Ten patients with objective patellar instability who underwent distal realignment procedure using Fulkerson TTO were retrospectively reviewed. The osteotomy was secured with two parallel 4.8 mm magnesium screws in all patients. Kujala score and Lysholm knee score were used to assess the functional outcomes before and after the operation. Union of the osteotomy, displacement, and other imaging findings were evaluated with serial knee radiographs during the follow-up. There were five male and five female patients with a mean age of 23.4±9.2 years (range, 15-45). The mean follow-up duration was 11.5±3.2 months (range,6-17 months). The osteotomy united in all cases at an average of 3 months. No infection or wound healing problems were seen. A significant increase in Kujala (p:.005) and Lysholm knee scores (p:.005) were recorded in all patients. The findings support that bioabsorbable magnesium screws can be safely used as an alternative fixation technique in TTO. Furthermore, it provides the advantage to eliminate the need for implant removal.

2 March 2017 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
ATAdil Turan
Adil Turan
Ozkan KoseOzkan Kose
Ozkan Kose
BABaver Acar
Baver Acar
MUMelih Unal
Melih Unal

23 September 2020 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
PDF file
YKYusuf Alper Katı
Yusuf Alper Katı
ÖÖÖzdamar Fuad Öken
Özdamar Fuad Öken
AYAhmet Özgür Yıldırım
Ahmet Özgür Yıldırım
ÖKÖzkan Köse
Özkan Köse
MUMelih Unal
Melih Unal
This study aims to compare intramedullary nailing (IMN) and minimally invasive plate osteosynthesis (MIPO) treatment methods in Arbeitsgemeinschaft für Osteosynthesefragen (AO) 42A1 & 42B1 selected tibial shaft fractures. Fifty-one patients (31 males, 20 females; mean age 43.5±14.2 years; range, 18 to 81 years) operated for AO 42A1 or AO 42B1 tibial shaft fractures between January 2006 and January 2012 were retrospectively evaluated. Twenty-three of these patients were treated with MIPO and 28 with IMN. Patients were compared in terms of union time, return to work, infection, malunion, hospital stay, and sixth month and two-year Lower Extremity Functional Scale (LEFS) values. There was no difference between the MIPO and IMN groups in terms of demographic data, etiology, and fracture patterns. The mean follow-up time was 37.8±8.8 months in MIPO group and 35.9±8.7 months in IMN group. Union time (p=0.575), return to work (p=0.155), infection (p=0.643), malunion (p=0.471), and hospital stay (p=0.538) were all similar between groups. Although the LEFS value was higher in IMN group in sixth month (p=0.026), the two-year LEFS value was similar between groups (p=0.085). Results of the study showed that both treatment methods are similar regarding clinical and functional outcomes. According to these results, MIPO can be recommended as an alternative to IMN in tibial shaft fractures formed as spiral oblique and spiral wedge.