Yao Sun

Dr. Yao Sun

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2019 in BMC Pediatrics
Verified
Journal Article
Open access
PDF file
Linda S. FranckLinda S. Franck
Linda S. Franck
RKRebecca M. Kriz
Rebecca M. Kriz
RBRobin Bisgaard
Robin Bisgaard
DCDiana M. Cormier
Diana M. Cormier
PJPriscilla Joe
Priscilla Joe
YSYao Sun
Yao Sun
Background: Family Centered Care (FCC) has been widely adopted as the framework for caring for infants in the Neonatal Intensive Care Unit (NICU) but it is not uniformly defined or practiced, making it difficult to determine impact. Previous studies have shown that implementing the Family Integrated Care (FICare) intervention program for preterm infants in the NICU setting leads to significant improvements in infant and family outcomes. Further research is warranted to determine feasibility, acceptability and differential impact of FICare in the US context. The addition of a mobile application (app) may be effective in providing supplemental support for parent participation in the FICare program and provide detailed data on program component uptake and outcomes.Methods: This exploratory multi-site quasi-experimental study will compare usual FCC with mobile enhanced FICare (mFICare) on growth and clinical outcomes of preterm infants born at or before 33 weeks gestational age, as well as the stress, competence and self-efficacy of their parents. The feasibility and acceptability of using mobile technology to gather data about parent involvement in the care of preterm infants receiving FCC or mFICare as well as of the mFICare intervention will be evaluated (Aim 1). The effect sizes for infant growth (primary outcome) and for secondary infant and parent outcomes at NICU discharge and three months after discharge will be estimated (Aim 2).Discussion: This study will provide new data about the implementation of FICare in the US context within various hospital settings and identify important barriers, facilitators and key processes that may contribute to the effectiveness of FICare. It will also offer insights to clinicians on the feasibility of a new mobile application to support parent-focused research and promote integration of parents into the NICU care team in US hospital settings.Trial registration: ClinicalTrials.gov, IDNCT03418870. Retrospectively registered on December 18, 2017.

1 November 2021 in Patient Education and Counseling
Verified
Journal Article
Open access
SFStephannie L. Furtak
Stephannie L. Furtak
CGCaryl L. Gay
Caryl L. Gay
RKRebecca M. Kriz
Rebecca M. Kriz
RBRobin Bisgaard
Robin Bisgaard
SBScott C. Bolick
Scott C. Bolick
Linda S. FranckLinda S. Franck
Linda S. Franck
To describe the characteristics of parent knowledge needs and skill acquisition over the course of their infant's neonatal intensive care unit hospitalization. 148 parents/guardians of infants ≤33 week gestation enrolled during the usual care phase of a multi-site quasi-experimental study, completing weekly surveys about their learning needs for the coming week and skills learned in the past week. The topics of most interest or concern for parents included feeding their infant and their infant's medical course. Knowledge needs varied by phase of hospitalization (early, middle, late) and by parent age, prior parenting experience, infant gestational age and hospital length of stay. The most common skills learned related to feeding and basic infant care. The number of skills parents reported learning each week varied by parent age, gender, and education. Parents of preterm infants expressed specific learning needs and acquisition of skills that varied over the course of the hospitalization and by parent and infant characteristics. The findings can be used to improve parent learning experiences so that they can become full partners in their infant's caregiving and are better prepared to care for their infant after discharge. ClinicalTrials.gov, ID NCT03418870.

1 April 2018 in Neuroscience Letters
Verified
Journal Article
Closed access
HZHuan Zhu
Huan Zhu
LQLixing Qiao
Lixing Qiao
YSYao Sun
Yao Sun
LYLiping Yin
Liping Yin
LHLi Huang
Li Huang
Jiaqing LiJiaqing Li
Jiaqing Li

22 December 2020 in Children
Verified
Journal Article
Open access
PDF file
Harpreet SinghHarpreet Singh
Harpreet Singh
SKSatoshi Kusuda
Satoshi Kusuda
RMRyan Michael McAdams
Ryan Michael McAdams
SGShubham Gupta
Shubham Gupta
JKJayant Kalra
Jayant Kalra
YSYao Sun
Yao Sun
Our objective in this study was to determine if machine learning (ML) can automatically recognize neonatal manipulations, along with associated changes in physiological parameters. A retrospective observational study was carried out in two Neonatal Intensive Care Units (NICUs) between December 2019 to April 2020. Both the video and physiological data (heart rate (HR) and oxygen saturation (SpO2)) were captured during NICU hospitalization. The proposed classification of neonatal manipulations was achieved by a deep learning system consisting of an Inception-v3 convolutional neural network (CNN), followed by transfer learning layers of Long Short-Term Memory (LSTM). Physiological signals prior to manipulations (baseline) were compared to during and after manipulations. The validation of the system was done using the leave-one-out strategy with input of 8 s of video exhibiting manipulation activity. Ten neonates were video recorded during an average length of stay of 24.5 days. Each neonate had an average of 528 manipulations during their NICU hospitalization, with the average duration of performing these manipulations varying from 28.9 s for patting, 45.5 s for a diaper change, and 108.9 s for tube feeding. The accuracy of the system was 95% for training and 85% for the validation dataset. In neonates <32 weeks’ gestation, diaper changes were associated with significant changes in HR and SpO2, and, for neonates ≥32 weeks’ gestation, patting and tube feeding were associated with significant changes in HR. The presented system can classify and document the manipulations with high accuracy. Moreover, the study suggests that manipulations impact physiological parameters.

4 October 2023 in Transportation Research Part D: Transport and Environment
Verified
Journal Article
Closed access
YSYao Sun
Yao Sun
YLYuxiang Liao
Yuxiang Liao
LWLiying Wei
Liying Wei
ZBZijian Bai
Zijian Bai

25 May 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
Harpreet SinghHarpreet Singh
Harpreet Singh
RKRavneet Kaur
Ravneet Kaur
SSSatish Saluja
Satish Saluja
SCSu Jin Cho
Su Jin Cho
YSYao Sun
Yao Sun
RMRyan Michael McAdams
Ryan Michael McAdams
Objective: To develop and evaluate an edge-hosted Large Language Model (LLM)-assisted system for automated Neonatal Intensive Care Unit (NICU) discharge summary generation using an evidence-grounded, field-level evaluation framework. Methods: This implementation and evaluation study was conducted in a Level III NICU in India. Longitudinal patient records were constructed from integrated bedside physiologic data (ARCHITECT) and a structured electronic medical record (EMR) platform Although an embedded audio–video module was present, it was not used in this study. Automated discharge summaries were generated by MORPHEUS, an edge-hosted orchestration pipeline running on NVIDIA Jetson AGX Orin hardware with JetPack 6.2. Local orchestration, preprocessing, and workflow execution were performed on the edge device, while language generation inference was performed using the OpenAI gpt-4o-mini API. Documentation quality was assessed with an LLM-based evaluator guided by a clinician-defined rubric comprising 72 fields organized across 14 section contexts and scored on five dimensions: clinical accuracy, completeness, actionability, coherence, and non-hallucination. Paired, field-level comparisons were performed against clinician-authored summaries. Of 549 NICU admissions screened between 1 October 2024 and 3 November 2025, 401 met the inclusion criteria for evaluation. Prompt refinement was performed iteratively using omission-derived feedback without model weight updates. Results: Across 401 evaluated admissions, MORPHEUS-generated summaries demonstrated higher rubric-based scores and lower omission burden than clinician-authored summaries within the structured evaluation framework used in this study, with mean scores of 0.93 versus 0.75 for accuracy, 0.91 versus 0.67 for completeness, 0.93 versus 0.72 for actionability, 0.94 versus 0.74 for coherence, and 0.95 versus 0.78 for non-hallucination, with the largest absolute advantage observed for completeness. Error taxonomy analysis demonstrated fewer omissions, unsupported assertions, and contradictions in AI-generated summaries than in clinician-authored summaries. Iterative prompt refinement was associated with directional improvement across quality dimensions and reduced omission burden, with omission rate per patient decreasing from 2.484 to 1.807 in the later iteration. Conclusions: An edge-hosted LLM-assisted pipeline can generate NICU discharge summaries that meet or exceed clinician-authored documentation quality under a reproducible, clinician-grounded evaluation framework. These findings support the feasibility of deploying edge-orchestrated generative AI systems for high-stakes neonatal clinical documentation using a clinician-grounded field-level evaluation framework.