Yue-Xin Wang

Ms. Yue-Xin Wang


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2026 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SWShi-Yao Wang
Shi-Yao Wang
YWYue-Xin Wang
Yue-Xin Wang
李政李 文 政
李 文 政
李李李梦遥 李
李梦遥 李
JGJiayi Gao
Jiayi Gao
HGHong-Zhang Geng
Hong-Zhang Geng
Carbon nanotube (CNT) materials exhibit ultrahigh electrical and thermal conductivity. Upon electrical excitation, CNT-based transparent conductive films (TCFs) can emit far-infrared radiation (FIR) and provide certain physiotherapeutic efficacy, making them ideal candidates for thermotherapy applications. This work systematically tests and analyzes the fundamental physical properties and physiotherapeutic performance of CNT flexible thin-film heaters (TFHs) for potential use in health physiotherapy. Two types of TFHs with different electrode connection modes were fabricated via the prepared TCFs. Experimental characterizations were conducted on their response time, electrothermal performance, and heat transfer characteristics. The results showed that the temperature rise per unit input power for TFH1 was 16.71 °C/W, while that of TFH2 was 4.29 °C/W at the same voltage of 10 V. In addition, the variation trends of maximum temperature with power density were highly consistent for the two films. This demonstrates that TFHs fabricated using the same TCFs exhibit excellent and high electrothermal conversion efficiency as well as outstanding comprehensive electrothermal performance. In addition, smaller L/W ratio leads to lower resistance of TFHs, resulting in a stronger thermal effect under identical applied voltage. After the temperature stabilized, the surface temperature of the TFHs decreased by approximately 5 °C when attached to the human arm, confirming that the heat generated by the TFHs under electrical excitation could be effectively absorbed by the human body. The TFHs emitted rapid FIR upon electrification, and the peak wavelength ranged from 8 to 12 µm, which fell within the range of 6–14 µm that was easily absorbable by the human body. The heat can be rapidly absorbed by the skin and distributed throughout the body via blood circulation, yielding favorable physiotherapeutic efficacy. This study provides key physical parameters for the application of TFHs in wearable medical devices and physiotherapy equipment.