Sasan Sadrizadeh

Dr. Sasan Sadrizadeh

A Professor
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2022 in Journal of Building Engineering
Verified
Journal Article
Open access
SSSasan Sadrizadeh
Sasan Sadrizadeh
RYRunming Yao
Runming Yao
FYFeng Yuan
Feng Yuan
HAHazim Awbi
Hazim Awbi
WBWilliam Bahnfleth
William Bahnfleth
BLBaizhan Li
Baizhan Li

1 April 2014 in Particuology
Verified
Journal Article
Closed access
SSSasan Sadrizadeh
Sasan Sadrizadeh
ATAnn Tammelin
Ann Tammelin
PEPeter Ekolind
Peter Ekolind
SHSture Holmberg
Sture Holmberg

3 June 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
ABAmirmohammad Behzadi
Amirmohammad Behzadi
SHSture Holmberg
Sture Holmberg
CDChristophe Duwig
Christophe Duwig
FHFariborz Haghighat
Fariborz Haghighat
RORyozo Ooka
Ryozo Ooka
SSSasan Sadrizadeh
Sasan Sadrizadeh

1 September 2018 in Journal of Infection and Public Health
Verified
Journal Article
Open access
SSSasan Sadrizadeh
Sasan Sadrizadeh
JPJovan Pantelic
Jovan Pantelic
MSMax Sherman
Max Sherman
JCJordan Clark
Jordan Clark
OAOmid Abouali
Omid Abouali
Operating rooms (ORs) are usually over-pressurized in order to prevent the penetration of contaminated air and the consequent risk of surgical site infection. However, a door-opening can result in the rapid disappearance of pressure and contaminants can then easily penetrate into the surgical zone. Therefore, a broad knowledge and understanding of OR ventilation systems and their protective potential is essential for optimizing the surgical environment. This study investigated the air quality and level of airborne particles during a single and multiple door-opening cycles in an operating room supplied by a turbulent-mixing ventilation system. The exploration was carried out numerically using computational fluid dynamics. Model validation was performed to ensure the validity of the achieved results. The OR was initially over-pressurized by approximately 15Pa, relative to the adjacent corridors. Both sliding and hinged doors were simulated and compared. Penetration of bacteria carrying particles from the corridors to the OR can be successfully restricted by using a positive-pressure system. However, the results clearly indicate that frequent door opening can interfere with airflow ventilation systems, alter the pressure gradient, and increase the infection risk for the patient undergoing surgical intervention. Door-opening disturbs the airflow field and could result in containment failure.

1 October 2018 in Building and Environment
Verified
Journal Article
Closed access
CWCong Wang
Cong Wang
SHSture Holmberg
Sture Holmberg
SSSasan Sadrizadeh
Sasan Sadrizadeh

1 December 2014 in Building and Environment
Verified
Journal Article
Closed access
SSSasan Sadrizadeh
Sasan Sadrizadeh
SHSture Holmberg
Sture Holmberg
ATAnn Tammelin
Ann Tammelin