OBJECTIVE The accurate quantification of human diabetic neuropathy is important to define at-risk patients, anticipate deterioration, and assess new therapies. RESEARCH DESIGN AND METHODS A total of 101 diabetic patients and 17 age-matched control subjects underwent neurological evaluation, neurophysiology tests, quantitative sensory testing, and evaluation of corneal sensation and corneal nerve morphology using corneal confocal microscopy (CCM). RESULTS Corneal sensation decreased significantly (P = 0.0001) with increasing neuropathic severity and correlated with the neuropathy disability score (NDS) (r = 0.441, P < 0.0001). Corneal nerve fiber density (NFD) (P < 0.0001), nerve fiber length (NFL), (P < 0.0001), and nerve branch density (NBD) (P < 0.0001) decreased significantly with increasing neuropathic severity and correlated with NDS (NFD r = −0.475, P < 0.0001; NBD r = −0.511, P < 0.0001; and NFL r = −0.581, P < 0.0001). NBD and NFL demonstrated a significant and progressive reduction with worsening heat pain thresholds (P = 0.01). Receiver operating characteristic curve analysis for the diagnosis of neuropathy (NDS >3) defined an NFD of 6) defined a NFD cutoff of <20.8/mm2 with a sensitivity of 0.71 (0.42–0.92) and specificity of 0.64 (0.54–0.74). CONCLUSIONS CCM is a noninvasive clinical technique that may be used to detect early nerve damage and stratify diabetic patients with increasing neuropathic severity.
Aim: To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. Methods: A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate between NSK and SK, based on the severity of signs and symptoms. The size of the hospital catchment population and the wearing modalities (daily wear (DW) or extended wear (EW)) and lens types being used were estimated from relevant demographic and market data. Results: During the survey period, 80 and 38 patients presented with NSK and SK, respectively. The annual incidences (cases per 10 000 wearers) for each wearing modality and lens type were: DW rigid—NSK 5.7, SK 2.9; DW hydrogel daily disposable—NSK 9.1, SK 4.9; DW hydrogel (excluding daily disposable)—NSK 14.1, SK 6.4; DW silicone hydrogel—NSK 55.9, SK 0.0; EW rigid—NSK 0.0, SK 0.0; EW hydrogel—NSK 48.2, SK 96.4; EW silicone hydrogel—NSK 98.8, SK 19.8. The difference in SK between EW hydrogel and EW silicone hydrogel was significant (p = 0.04). Conclusions: A clinical severity matrix has considerable utility in assessing contact lens related keratitis. There is a significantly higher incidence of SK in wearers who sleep in contact lenses compared with those who only use lenses during the waking hours. Those who choose to sleep in lenses should be advised to wear silicone hydrogel lenses, which carry a five times decreased risk of SK for extended wear compared with hydrogel lenses.
1 October 2013 in Investigative Ophthalmology & Visual Science
Purpose: To establish intraobserver and interobserver repeatability, agreement, and symmetry of corneal nerve fiber (NF) morphology in healthy subjects using in vivo corneal confocal microscopy. Methods: Nineteen subjects underwent in vivo corneal confocal microscopy (Heidelberg Retinal Tomograph III Rostock Cornea Module) at baseline and 7 days apart. Bland–Altman plots were generated to assess agreement, and the intraclass correlation coefficient and coefficient of repeatability were calculated to estimate intraobserver and interobserver repeatability for corneal NF density (numbers per square millimeter), nerve branch density (NBD; numbers per square millimeter), NF length (millimeters per square millimeter), and NF tortuosity coefficient. Symmetry between the right and left eyes was also assessed. Results: Intraclass correlation coefficient and coefficient of repeatability for intraobserver repeatability were 0.66 to 0.74 and 0.17 to 0.64, for interobserver repeatability 0.54 to 0.93 and 0.15 to 0.85, and for symmetry 0.34 to 0.77 and 0.17 to 0.63, respectively. NBD demonstrated low repeatability. Conclusions: This study demonstrates good repeatability for the manual assessment of all major corneal NF parameters with the exception of NBD, which highlights the difficulty in defining nerve branches and suggests the need for experienced observers or automated image analysis to ensure optimal repeatability.
Purpose To determine whether the more rapid cooling of the tear film in dry eyes is related to other tear film parameters, a battery of tear physiology tests was performed on dry eye patients and control subjects. Methods Tear evaporation rate was measured with a modified Servomed (vapour pressure) evaporimeter and ocular temperature with an NEC San-ei 6T62 Thermo Tracer in 9 patients diagnosed as having dry eye and in 13 healthy control subjects. Variability in temperature across the ocular surface was described by the temperature variation factor (TVF). Lipid layer structure and tear film stability were assessed with the Keeler Tearscope and tear osmolality was measured by freezing point depression nanolitre osmometry. Results The data were explored by principal component analysis. The subjects with and without dry eye could be separated into two distinct groups entirely on the basis of their tear physiology. Dry eye patients exhibited higher tear evaporation rates, osmolalities and TVF, lower tear film stabilities and poorer- quality lipid layers than the control subjects. A significant linear relationship was found to exist between tear evaporation rate and TVF for all subjects (R2 = 0.242, p = 0.024). Conclusions Rapid cooling of the tear film in dry eyes appears to be related to the reduced stability of the tears and the increased rate of evaporation. The higher latent heat of vaporisation, associated with the increased evaporation in dry eyes, may account for the increased rate of cooling of the tear film in this condition.