Jaewon Yang

Dr. Jaewon Yang

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JYJaewon Yang
Jaewon Yang
DPDookun Park
Dookun Park
GGGrant T Gullberg
Grant T Gullberg
YSYoungho Seo
Youngho Seo
Dedicated brain positron emission tomography (PET) devices can provide higher-resolution images with much lower doses compared to conventional whole-body PET systems, which is important to support PET neuroimaging and particularly useful for the diagnosis of neurodegenerative diseases. However, when a dedicated brain PET scanner does not come with a combined CT or transmission source, there is no direct solution for accurate attenuation and scatter correction, both of which are critical for quantitative PET. To address this problem, we propose joint attenuation and scatter correction (ASC) in image space for non-corrected PET (PET NC ) using deep convolutional neural networks (DCNNs). This approach is a one-step process, distinct from conventional methods that rely on generating attenuation maps first that are then applied to iterative scatter simulation in sinogram space . For training and validation, time-of-flight PET/MR scans and additional helical CTs were performed for 35 subjects (25/10 split for training and test dataset). A DCNN model was proposed and trained to convert PET NC to DCNN-based ASC PET (PET DCNN ) directly in image space . For quantitative evaluation, uptake differences between PET DCNN and reference CT-based ASC PET (PET CT-ASC ) were computed for 116 automated anatomical labels (AALs) across 10 test subjects (1160 regions in total). MR-based ASC PET (PET MR-ASC ), a current clinical protocol in PET/MR imaging, was another reference for comparison. Statistical significance was assessed using a paired t test. The performance of PET DCNN was comparable to that of PET MR-ASC , in comparison to reference PET CT-ASC . The mean SUV differences (mean ± SD) from PET CT-ASC were 4.0% ± 15.4% ( P < 0.001) and −4.2% ± 4.3% ( P < 0.001) for PET DCNN and PET MR-ASC , respectively. The overall larger variation of PET DCNN (15.4%) was prone to the subject with the highest mean difference (48.5% ± 10.4%). The mean difference of PET DCNN excluding the subject was substantially improved to −0.8% ± 5.2% ( P < 0.001), which was lower than that of PET MR-ASC (−5.07% ± 3.60%, P < 0.001). In conclusion, we demonstrated the feasibility of directly producing PET images corrected for attenuation and scatter using a DCNN (PET DCNN ) from PET NC in image space without requiring conventional attenuation map generation and time-consuming scatter correction. Additionally, our DCNN-based method provides a possible alternative to MR-ASC for simultaneous PET/MRI.

26 February 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
JYJaewon Yang
Jaewon Yang
LSLuyao Shi
Luyao Shi
RWRui Wang
Rui Wang
EMEdward J. Miller
Edward J. Miller
ASAlbert J. Sinusas
Albert J. Sinusas
YSYoungho Seo
Youngho Seo
Purpose: Dedicated cardiac SPECT scanners with cadmium-zinc-telluride (CZT) cameras have shown capabilities of shortened scan times or reduced radiation doses as well as improved image quality. Since most of the dedicated scanners do not have an integrated CT, image quantification with attenuation correction (AC) is challenging and artifacts are routinely encountered in daily clinical practice. In this work, we demonstrate a direct AC technique using deep learning (DL) for myocardial perfusion imaging (MPI). Methods: In an IRB-approved retrospective study, 100 cardiac SPECT/CT datasets with 99mTc-tetrofosmin using a GE Discovery NM/CT 570c scanner were collected at the Yale New Haven Hospital. A U-Net-based network was used for generating attenuation-corrected SPECT (SPECTDL) directly from non-corrected SPECT (SPECTNC) without undergoing an additional image reconstruction step. The accuracy of SPECTDL was evaluated by voxel-wise and segment-wise analyses against the reference CT-based AC (SPECTCTAC) using American Heart Association 17 segments in the myocardium. Polar maps of representative (best/median/worst) cases were visually compared for illustrating potential benefits and pitfalls of the DL approach. Results: The voxel-wise correlations with SPECTCTAC were 92.2% ± 3.7 (slope = 0.87; R2 = 0.81) and 97.7% ± 1.8 (slope = 0.94; R2 = 0.91) for SPECTNC and SPECTDL, respectively. The segmental errors of SPECTNC scattered from -35% up to 21% (P < 0.001); while, the errors of SPECTDL stayed mostly within ±10% (P < 0.001). The average segmental errors (mean±SD) were -6.11 ± 8.06% and 0.49 ± 4.35% for SPECTNC and SPECTDL, respectively. The average absolute segmental errors were 7.96 ± 6.23% and 3.31 ± 2.87% for SPECTNC and SPECTDL, respectively. Review of polar maps revealed successful demonstration of reduced attenuation artifacts; however, the performance of SPECTDL was not consistent for all subjects likely due to different amount of attenuation and uptake patterns. Conclusion: We demonstrated the feasibility of direct AC using DL for SPECT MPI. Overall, our DL approach reduced attenuation artifacts substantially compared to SPECTNC, justifying further studies to establish safety and consistency for clinical applications in stand-alone SPECT systems suffered from attenuation artifacts.

1 March 2021 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
JYJaewon Yang
Jaewon Yang
JSJae Ho Sohn
Jae Ho Sohn
SBSpencer Behr
Spencer Behr
GGGrant T. Gullberg
Grant T. Gullberg
YSYoungho Seo
Youngho Seo
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...

4 May 2017 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
JYJaewon Yang
Jaewon Yang
FWFlorian Wiesinger
Florian Wiesinger
SKSandeep Kaushik
Sandeep Kaushik
DSDattesh Shanbhag
Dattesh Shanbhag
THThomas A. Hope
Thomas A. Hope
YSYoungho Seo
Youngho Seo
In brain PET/MRI, the major challenge of zero-echo-time (ZTE)–based attenuation correction (ZTAC) is the misclassification of air/tissue/bone mixtures or their boundaries. Our study aimed to evaluate a sinus/edge-corrected (SEC) ZTAC (ZTACSEC), relative to an uncorrected (UC) ZTAC (ZTACUC) and a CT atlas-based attenuation correction (ATAC). Methods: Whole-body 18F-FDG PET/MRI scans were obtained for 12 patients after PET/CT scans. Only data acquired at a bed station that included the head were used for this study. Using PET data from PET/MRI, we applied ZTACUC, ZTACSEC, ATAC, and reference CT-based attenuation correction (CTAC) to PET attenuation correction. For ZTACUC, the bias-corrected and normalized ZTE was converted to pseudo-CT with air (−1,000 HU for ZTE < 0.2), soft-tissue (42 HU for ZTE > 0.75), and bone (−2,000 × [ZTE − 1] + 42 HU for 0.2 ≤ ZTE ≤ 0.75). Afterward, in the pseudo-CT, sinus/edges were automatically estimated as a binary mask through morphologic processing and edge detection. In the binary mask, the overestimated values were rescaled below 42 HU for ZTACSEC. For ATAC, the atlas deformed to MR in-phase was segmented to air, inner air, soft tissue, and continuous bone. For the quantitative evaluation, PET mean uptake values were measured in twenty 1-mL volumes of interest distributed throughout brain tissues. The PET uptake was compared using a paired t test. An error histogram was used to show the distribution of voxel-based PET uptake differences. Results: Compared with CTAC, ZTACSEC achieved the overall PET quantification accuracy (0.2% ± 2.4%, P = 0.23) similar to CTAC, in comparison with ZTACUC (5.6% ± 3.5%, P < 0.01) and ATAC (−0.9% ± 5.0%, P = 0.03). Specifically, a substantial improvement with ZTACSEC (0.6% ± 2.7%, P < 0.01) was found in the cerebellum, in comparison with ZTACUC (8.1% ± 3.5%, P < 0.01) and ATAC (−4.1% ± 4.3%, P < 0.01). The histogram of voxel-based uptake differences demonstrated that ZTACSEC reduced the magnitude and variation of errors substantially, compared with ZTACUC and ATAC. Conclusion: ZTACSEC can provide an accurate PET quantification in brain PET/MRI, comparable to the accuracy achieved by CTAC, particularly in the cerebellum.

3 July 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
KGKuang Gong
Kuang Gong
JYJaewon Yang
Jaewon Yang
PLPeder Larson
Peder Larson
SBSpencer C. Behr
Spencer C. Behr
THThomas A Hope
Thomas A Hope
Quanzheng LiQuanzheng Li
Quanzheng Li
Attenuation correction (AC) is important for the quantitative merits of positron emission tomography (PET). However, attenuation coefficients cannot be derived from magnetic resonance (MR) images directly for PET/MR systems. In this work, we aimed to derive continuous AC maps from Dixon MR images without the requirement of MR and computed tomography (CT) image registration. To achieve this, a 3-D generative adversarial network with both discriminative and cycle-consistency loss (Cycle-GAN) was developed. The modified 3-D U-net was employed as the structure of the generative networks to generate the pseudo-CT/MR images. The 3-D patch-based discriminative networks were used to distinguish the generated pseudo-CT/MR images from the true CT/MR images. To evaluate its performance, datasets from 32 patients were used in the experiment. The Dixon segmentation and atlas methods provided by the vendor and the convolutional neural network (CNN) method which utilized registered MR and CT images were employed as the reference methods. Dice coefficients of the pseudo-CT images and the regional quantification in the reconstructed PET images were compared. Results show that the Cycle-GAN framework can generate better AC compared to the Dixon segmentation and atlas methods, and shows comparable performance compared to the CNN method.

1 July 2017 in Radiology
Verified
Journal Article
Closed access
JYJaewon Yang
Jaewon Yang
YJYiqiang Jian
Yiqiang Jian
NJNathaniel Jenkins
Nathaniel Jenkins
SBSpencer C. Behr
Spencer C. Behr
THThomas A. Hope
Thomas A. Hope
YSYoungho Seo
Youngho Seo
Our results demonstrated that patient-specific anatomic differences from the atlas caused bone attenuation differences and misclassification of sinuses, resulting in patient-dependent performance variation of atlas-based attenuation correction. PurposeTo assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system.Materials and MethodsThirty recruited patients provided informed consent in this institutional review board–approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATACpatientBone (air and tissue from the atlas with patient bone), and PET with ATACboneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test.Results...