Thomas Beiert

Dr. Thomas Beiert

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2024 in Nature Medicine
Verified
Journal Article
Open access
PDF file
EEEmmanuel Ekanem
Emmanuel Ekanem
PNPetr Neuzil
Petr Neuzil
TRTobias Reichlin
Tobias Reichlin
JKJoseph Kautzner
Joseph Kautzner
PVPepijn van der Voort
Pepijn van der Voort
VRVivek Y. Reddy
Vivek Y. Reddy
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.

6 December 2017 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
TBThomas Beiert
Thomas Beiert
PLPia C. Lodde
Pia C. Lodde
LLLutz P.T. Linneborn
Lutz P.T. Linneborn
JWJessica Werner
Jessica Werner
LPLisa Prinz
Lisa Prinz
RARené P. Andrié
René P. Andrié

1 January 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
TBThomas Beiert
Thomas Beiert
VKVincent Knappe
Vincent Knappe
VTVedat Tiyerili
Vedat Tiyerili
FSFlorian Stöckigt
Florian Stöckigt
VEVerena Effelsberg
Verena Effelsberg
RARené P. Andrié
René P. Andrié

1 August 2017 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
TBThomas Beiert
Thomas Beiert
VTVedat Tiyerili
Vedat Tiyerili
VKVincent Knappe
Vincent Knappe
VEVerena Effelsberg
Verena Effelsberg
MLMarkus Linhart
Markus Linhart
RARené P. Andrié
René P. Andrié

19 September 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
IEIbrahim El-Battrawy
Ibrahim El-Battrawy
KKKatharina Koepsel
Katharina Koepsel
DTDavid Tenbrink
David Tenbrink
BKBoldizsar Kovacs
Boldizsar Kovacs
TDTobias C. Dreher
Tobias C. Dreher
TBThomas Beiert
Thomas Beiert
Background: Data on the use of the wearable cardioverter‐defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results: In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin‐converting enzyme inhibitors (62.5%), angiotensin‐receptor‐neprilysin inhibitor (22.9%), aldosterone‐antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%–45%) and increased to 48% (39%–55%) over long‐term follow‐up ( P <0.001). The median BNP (brain natriuretic peptide) level at baseline was 1702 pg/mL (565–3748) and decreased to 188 pg/mL (26–348) over long‐term follow‐up ( P =0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions: Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.

1 September 2017 in Journal of Electrocardiology
Verified
Journal Article
Closed access
TBThomas Beiert
Thomas Beiert
RMRobert Malotki
Robert Malotki
NKNatalie Kraemer
Natalie Kraemer
FSFlorian Stöckigt
Florian Stöckigt
MLMarkus Linhart
Markus Linhart
RARené P. Andrié
René P. Andrié