Francisco Noé Demesa López

Dr. Francisco Noé Demesa López

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
GEGermán Escalante
Germán Escalante
RLRoberto López
Roberto López
FDFrancisco Noé Demesa
Francisco Noé Demesa
GVGerardo Villa-Sánchez
Gerardo Villa-Sánchez
Victor Hugo Castrejón-SánchezVictor Hugo Castrejón-Sánchez
Victor Hugo Castrejón-Sánchez
IVISRAEL VIVALDO
ISRAEL VIVALDO
The color exhibited by tungsten trioxide (WO3) can be associated with both its stoichiometry and crystallinity. Correlation between the color exhibited by WO3 powders and their purity and crystalline properties is reported in this paper. The WO3 powders were deposited by evaporation of tungsten trioxide from the surface of a tungsten filament. The WO3 powders exhibited three different shades of blue: navy, royal, and sky. The color of the WO3 powders changed to white after thermal treatment at 500 °C for 30 min in an ambient atmosphere. Raman analyses showed that transition from amorphous to crystalline WO3 started when the powders exhibited navy-blue color and ended when WO3 powders exhibited a white color. Scanning electron microscopy analysis showed particle agglomeration characteristics in all WO3 powders, even after they were thermally treated. The mechanism of deposition of WO3 from the tungsten filament was suggested to be governed by thermal evaporation of tungsten trioxide from the surface of the oxidized tungsten filament.

1 March 2015 in Applied Thermal Engineering
Verified
Journal Article
Closed access
NDN. Demesa
N. Demesa
JHJ.A. Hernández
J.A. Hernández
JSJ. Siqueiros
J. Siqueiros
JGJuan Carlos Garcia
Juan Carlos Garcia
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea

1 January 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
DCDario Colorado-Garrido
Dario Colorado-Garrido
NDN. Demesa
N. Demesa
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea
JHJ.A. Hernández
J.A. Hernández

1 May 2018 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
NDN. Demesa
N. Demesa
JHJ.A. Hernández
J.A. Hernández
JSJ. Siqueiros
J. Siqueiros
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea

1 November 2017 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
NDN. Demesa
N. Demesa
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea
JHJ.A. Hernandez
J.A. Hernandez
JSJ. Siqueiros
J. Siqueiros

11 February 2020 in Experimental Heat Transfer
Verified
Journal Article
Closed access
NDNoé Demesa
Noé Demesa
JHJosé Alfredo Hernández
José Alfredo Hernández
DJDavid Juárez
David Juárez
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea
The studies of nested helical coil heat exchangers for an absorption heat transformer are very limited, although this arrangement has a greater heat transfer area in a smaller volume. The heat exchangers are vertically placed to develop the desorption, condensation, evaporation and absorption processes by falling film mode. The usage of energy from point of qualitative view in these times is mandatory, due to the fossil fuels reduction and pollution. This experimental study analyses the behavior the nested helical coils heat exchangers through the first and second law of thermodynamics. The physical and chemical exergy for the main components and whole system is calculated by using the conventional method. All the experimental tests are carried out by varying the source temperature from 343.15 to 358.15 K with heating mass flow rate in the generator between 0.07 and 0.13 kg/s. For this study, the condensation and absorption processes reach the highest exergy destruction at high temperatures, while the solution heat exchanger presents the lowest irreversibility. The exergy coefficient of performance always improves when the supplied heat in the generator increases owing to the heating mass flow rate and temperature, however there is an increment considerably of total irreversibility at 349.15 K.