To mitigate large-scale blackout risks in urban distribution systems under typhoon-induced extreme weather and to reduce post-disaster restoration costs, this study proposes a resilience-oriented spatiotemporal co-optimization framework integrating transportation networks, power grids, and distributed energy resources. First, a city-scale typhoon spatiotemporal model is established, integrating static wind field, dynamic evolution, and trajectory-based mobility with urban-geometry-driven wind speed correction to characterize the spatiotemporal progression of extreme wind hazards. Second, the time-varying failure rates of distribution network components are quantified by explicitly accounting for network topology correlations, while the spatiotemporal dispatchability and output characteristics of distributed resources under disaster conditions are systematically modeled. Third, a pre-disaster proactive deployment model is formulated to minimize load curtailment costs and resource allocation expenditures. The model integrates active network reconfiguration with coordinated placement of distributed generation (DG) and mobile energy storage systems (MESSs), enabling resilience-enhancing pre-positioning strategies. Subsequently, a post-disaster restoration scheduling model is developed with the objective of minimizing unserved load. By embedding traffic flow constraints and optimal path computation under disrupted transportation conditions, the proposed framework realizes spatiotemporal coordination among MESSs, DG, and electric vehicles (EVs), thereby accelerating system-level recovery. Finally, the effectiveness of the proposed strategy is validated on a 51-node urban distribution system located in eastern coastal China, demonstrating significant improvements in restoration performance and resilience enhancement.
To establish quantitative criteria for selecting the operating frequency of diode rectifier unit (DRU)-based medium-frequency AC collection and DC transmission systems, this paper proposes a life-cycle frequency-selection method for far-offshore wind power. A power-flow model incorporating wind-turbine Q–f droop control and frequency-dependent submarine-cable parameters is developed to evaluate voltage distribution, reactive-power accumulation, power factor, and steady-state losses. An electromagnetic transient model is then used to quantify energy losses caused by single-phase and three-phase AC-side short-circuit faults. These electrical results are integrated with cable and converter investment costs in a multi-stage life-cycle economic model that accounts for equipment aging and loss growth. For the studied Rudong 500 MW case under the adopted baseline parameters, medium-frequency operation increases submarine-cable reactive-power accumulation and fault losses, while the total life-cycle cost first decreases and then increases with frequency. The minimum cost occurs at 180 Hz. The proposed framework links steady-state performance, transient fault losses, and long-term economics, providing a project-oriented basis for selecting the operating frequency of DRU-based offshore wind transmission systems.