Tommaso Stefano Carzaniga

Mr. Tommaso Stefano Carzaniga

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2020 in Molecules
Verified
Journal Article
Open access
PDF file
NMNick Van der Meulen
Nick Van der Meulen
RHRoger Hasler
Roger Hasler
ZTZeynep Talip
Zeynep Talip
PGPascal V. Grundler
Pascal V. Grundler
CFChiara Favaretto
Chiara Favaretto
Saverio BracciniSaverio Braccini
Saverio Braccini
44Sc has favorable properties for cancer diagnosis using Positron Emission Tomography (PET) making it a promising candidate for application in nuclear medicine. The implementation of its production with existing compact medical cyclotrons would mean the next essential milestone in the development of this radionuclide. While the production and application of 44Sc has been comprehensively investigated, the development of specific targetry and irradiation methods is of paramount importance. As a result, the target was optimized for the 44Ca(p,n)44Sc nuclear reaction using CaO instead of CaCO3, ensuring decrease in target radioactive degassing during irradiation and increased radionuclidic yield. Irradiations were performed at the research cyclotron at the Paul Scherrer Institute (~11 MeV, 50 µA, 90 min) and the medical cyclotron at the University of Bern (~13 MeV, 10 µA, 240 min), with yields varying from 200 MBq to 16 GBq. The development of targetry, chemical separation as well as the practical issues and implications of irradiations, are analyzed and discussed. As a proof-of-concept study, the 44Sc produced at the medical cyclotron was used for a preclinical study using a previously developed albumin-binding prostate-specific membrane antigen (PSMA) ligand. This work demonstrates the feasibility to produce 44Sc with high yields and radionuclidic purity using a medical cyclotron, equipped with a commercial solid target station.

1 January 2019 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
TCTommaso Stefano Carzaniga
Tommaso Stefano Carzaniga
SBSaverio Braccini
Saverio Braccini

4 January 2019 in Instruments
Verified
Journal Article
Open access
PDF file
KNKonrad Pawel Nesteruk
Konrad Pawel Nesteruk
LRLuca Ramseyer
Luca Ramseyer
TCTommaso Stefano Carzaniga
Tommaso Stefano Carzaniga
Saverio BracciniSaverio Braccini
Saverio Braccini
Accurate knowledge of the beam energy distribution is crucial for particle accelerators, compact medical cyclotrons for the production of radioisotopes in particular. For this purpose, a compact instrument was developed, based on a multi-leaf Faraday cup made of thin aluminum foils interleaved with plastic absorbers. The protons stopping in the aluminum foils produce a measurable current that is used to determine the range distribution of the proton beam. On the basis of the proton range distribution, the beam energy distribution is assessed by means of stopping-power Monte Carlo simulations. In this paper, we report on the design, construction, and testing of this apparatus, as well as on the first measurements performed with the IBA Cyclone 18-MeV medical cyclotron in operation at the Bern University Hospital.

20 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CACarolina Belver Aguilar
Carolina Belver Aguilar
Saverio BracciniSaverio Braccini
Saverio Braccini
TCTommaso Stefano Carzaniga
Tommaso Stefano Carzaniga
GAGsponer Andreas
Gsponer Andreas
PHPhilipp Häffner
Philipp Häffner
MSMatthias Schmid
Matthias Schmid
A novel three-dimensional non-destructive beam monitor named π3 was conceived, realized and tested. It is based on a thin aluminum foil coated with P47 scintillating material mounted on a support, together with a miniaturized CCD camera, both moving along the beam axis. This detector allows reconstructing of the beam distribution along the beam path, providing either an on-line video or a graphical reconstruction of the beam envelope in 3D. The π3 detector is a general-purpose instrument suitable for any ion accelerator facility. As it is constructed with non-magnetic materials, it can be used to investigate the behavior of the beam inside beam optics components such as magnets. In this paper, we report the development of the first prototype of the π3 detector, its associated software and the results of the beam tests performed at the Bern medical cyclotron laboratory.

28 June 2018 in Instruments
Verified
Journal Article
Open access
PDF file
LGLars Gerchow
Lars Gerchow
Saverio BracciniSaverio Braccini
Saverio Braccini
TCTommaso Stefano Carzaniga
Tommaso Stefano Carzaniga
DCDavid Cooke
David Cooke
MDMax Döbeli
Max Döbeli
PCPaolo Crivelli
Paolo Crivelli
We report on the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV–few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the β+ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that, using an optimised setup, even higher efficiencies are achievable. A novel method for the production of 48V high-activity thin foil positron sources based on a solid target station at a medical cyclotron was developed. This is an improvement of more than one order of magnitude with respect to standard methods.

17 February 2019 in Instruments
Verified
Journal Article
Open access
PDF file
Saverio BracciniSaverio Braccini
Saverio Braccini
TCTommaso Stefano Carzaniga
Tommaso Stefano Carzaniga
GPGiulia Pisegna
Giulia Pisegna
Paola ScampoliPaola Scampoli
Paola Scampoli
The possibility of performing proton radiography by using the proton angular spread due to Coulomb multiple scattering was investigated, for the first time, with an emulsion film detector. Two different phantoms were irradiated with the therapeutic proton beam at the Paul Scherrer Institut (PSI) in Villigen, Switzerland. The first one is a simple polymethylmethacrylate (PMMA) block having two different thicknesses (4 cm and 3 cm), and the second one is a PMMA cube with five aluminum rods embedded along a diagonal. Only one emulsion film was needed to perform the radiography, an important issue as the analysis of this kind of detector is time-consuming. Furthermore, the method showed an enhanced contrast when high atomic-number materials are traversed. This gives an advantage, when compared to proton range radiography.