Zhen Li

Dr. Zhen Li

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
XYXiaokang Yin
Xiaokang Yin
CLChen Li
Chen Li
ZLZhen Li
Zhen Li
WLWei Li
Wei Li
GCGuoming Chen
Guoming Chen
Capacitive Imaging (CI) sensors are capable of non-destructively detecting both surface and hidden defects in dielectric materials and characterizing conducting surfaces through a relatively thick insulation layer. However, the complex Measurement Sensitivity Distribution (MSD) of CI sensors render the sensor capacitance variation with lift-off highly non-linear, which may lead to misinterpretation of defect indications. This work systematically studied the lift-off effect using both Finite Element (FE) analysis and experimental approaches. Sensor MSD was used as a tool to predict the imaging performance. Normalized Variation Ratio (NVR) was introduced and used to characterise sensor responses due to defects for a CI sensor. Both the FE analysis and experiments suggest that the lift-off effect for a CI sensor is specimen type and condition dependent. For a given defect, the NVR may vary non-monotonically with increased lift-offs. A case study on a glass-fibre composite/aluminium hybrid structure with multiple artificial defects demonstrated the feasibility of defects discrimination using multiple CI scans with increased lift-offs.

29 January 2020 in IEEE Access
Verified
Journal Article
Open access
XYXiaokang Yin
Xiaokang Yin
ZLZhen Li
Zhen Li
XYXian’an Yuan
Xian’an Yuan
WLWei Li
Wei Li
GCGuoming Chen
Guoming Chen
As a new Non-destructive Evaluation (NDE) technique, capacitive imaging (CI) has been used to detect defects in oil pipelines, composite sucker rods and storage tanks in recent years. When a CI sensor is used to detect corrosion defect on a conducting surface with or without an insulation layer, the depth information of corrosion defect is difficult to acquire due to the non-linearity of the probing field. This paper proposed a corrosion depth inversion method based on the lift-off effect of the CI technique. The proposed depth inversion method, which includes three steps, namely establishing the lift-off curve, obtaining the scan curve and fitting inversion, are introduced and evaluated. In the FE simulations, the error rates of the inversion depths are less than 1.20%. CI experiments were carried out to acquire the depth information of a step shape specimen using the CI experimental system and the proposed corrosion depth inversion method. The results show that the depth inversion method can meet the need of obtaining the actual depth information with the error rates of the inversion depths being less than 10.00%. A CI experiment on a machined and corroded specimen was carried out to further demonstrate the feasibility of the proposed inversion method for corrosion defects with different depths. Both results from FE models and experiments indicate that the proposed method is promising to achieve the quantitative NDE of the Corrosion Under Insulation (CUI).

19 November 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZLZhen Li
Zhen Li
GCGuoming Chen
Guoming Chen
YGYue Gu
Yue Gu
KWKefan Wang
Kefan Wang
WLWei Li
Wei Li
XYXiaokang Yin
Xiaokang Yin
As a novel non-destructive testing technique, capacitive imaging (CI) has been used to detect defects within the insulation layer and metal surface of an insulated metallic structure, that is, pipe or vessel. Due to the non-linearity of the probing field, the defects at different depths in the insulation layer are difficult to compare accurately using the conventional CI sensor with a single pair of electrodes. In addition, the conventional CI sensor cannot provide adequate information to discriminate the defects in the insulation layer and metal surface. In order to solve the above-mentioned problems, the multi-electrode sensor is introduced. The multi-electrode sensor uses multiple quasi-static fringing electric fields generated by an array of coplanar electrodes to obtain extra information about the defects in the specimen. In this work, the feasibility of multiple quasi-static electric fields detecting the defects was demonstrated and the Measurement Sensitivity Distributions (MSDs) of the multi-electrode sensor detecting the defects were acquired using the FEM models. The simulation and experimental results show that the Dynamic Change Rates (DCRs) of the measured values obtained at the center of the defects in the insulator layer and metal surface present different variation patterns, which can be used to discriminate these two different kinds of defects. The reasons for the different variation patterns of DCRs were explained by the changing trends of MSDs with increased electrode separation. In addition, it was demonstrated that the different depths of the defects in the insulator layer can be compared accurately by comprehensive analysis of the detection results from all the electrode pairs.

10 February 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HZHongyuan Zhang
Hongyuan Zhang
XYXiaokang Yin
Xiaokang Yin
GMGaofeng Ma
Gaofeng Ma
ZWZhenshun Wei
Zhenshun Wei
ZZZiheng Zhang
Ziheng Zhang
WLWei Li
Wei Li
Periodic Permanent Magnets Electromagnetic Acoustic Transducers (PPM EMATs) are commonly employed to generate Shear Horizontal (SH) guided waves for defect scanning in steel structures. During scanning, electromagnets can be used as alternatives to permanent magnets to generate static bias magnetic fields, thereby addressing the problem of permanent magnets attracting iron filings on the surface of steel structures. However, since the PPM EMATs have multiple magnet units and complex magnetic field distributions, replacing permanent magnets with electromagnets presents significant challenges. In this paper, a novel SH guided waves EMAT with Periodic Solenoid Coils (PSC) and a single magnet (referred to as the PSC EMAT) was developed. The design methodology for the PSC EMATs was presented, using the excitation of the single SH0 mode guided waves in a steel plate as a case study. The transduction process and excitation performance of the PSC EMATs were analyzed through both Finite Element (FE) simulations and experimental investigations. The results from both simulations and experiments demonstrate that the PSC EMAT can effectively generate single SH0 mode guided waves that propagate in four directions, with the forward directions identified as the primary orientations for defect inspection. These findings indicate that PSC EMATs can reliably generate and receive SH guided waves using a simplified static bias magnetic field, providing a foundation for the future application of electromagnets.