Don-Gey Liu

Prof. Don-Gey Liu

Department of Electronic Engineering, Feng Chia University, Taichung 40724, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in IEEE Access
Verified
Journal Article
Open access
STSONG-TOAN TRAN
SONG-TOAN TRAN
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
Medical image segmentation is one of the crucial tasks in diagnosis as well as pre-surgery. Recently, deep learning has significantly contributed to improving the efficiency of medical image extraction. The U-Net network has been a favored network model, which has been used as a platform architecture, for medical image segmentation. For the success of these studies, most of these models were primarily focused on the changing of the interconnection between the nodes in the network, and changing the structure of the convolution units. This would result in the ignorance of the output features of convolution units in the nodes. In this study, a U n -Net, an n-fold network architecture, was proposed based on the traditional U-Net. In the U n -Net model, the output features of the convolution units are taken as the skip connection. Therefore, the U n -Net network exploits the output features of the convolution units in the nodes. In this study, we investigated a U 2 -Net and a U 3 -Net for segmentation of the liver and liver tumors. Besides, dilated convolution (DC) and dense structure were also used in the nodes of our networks. The efficiency of our models was evaluated on two public datasets: LiTS and 3DIRCADb. The Dice’s Similarity Coefficient (DSC) of our proposed models achieved 96.38% for liver segmentation and 73.69% for tumor segmentation on the LiTS dataset. For the 3DIRCADb dataset, the results achieved 96.45% in DSC for the liver segmentation and 73.34% for the tumor segmentation. The experimental results show that our proposed networks achieved better results than the recent networks. And it is convinced that our network would be useful for practical deployments.

6 January 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
STSONG-TOAN TRAN
SONG-TOAN TRAN
CCChing-Hwa Cheng
Ching-Hwa Cheng
TNThanh-Tuan Nguyen
Thanh-Tuan Nguyen
HLHai Minh Le
Hai Minh Le
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
Deep learning is one of the most effective approaches to medical image processing applications. Network models are being studied more and more for medical image segmentation challenges. The encoder–decoder structure is achieving great success, in particular the Unet architecture, which is used as a baseline architecture for the medical image segmentation networks. Traditional Unet and Unet-based networks still have a limitation that is not able to fully exploit the output features of the convolutional units in the node. In this study, we proposed a new network model named TMD-Unet, which had three main enhancements in comparison with Unet: (1) modifying the interconnection of the network node, (2) using dilated convolution instead of the standard convolution, and (3) integrating the multi-scale input features on the input side of the model and applying a dense skip connection instead of a regular skip connection. Our experiments were performed on seven datasets, including many different medical image modalities such as colonoscopy, electron microscopy (EM), dermoscopy, computed tomography (CT), and magnetic resonance imaging (MRI). The segmentation applications implemented in the paper include EM, nuclei, polyp, skin lesion, left atrium, spleen, and liver segmentation. The dice score of our proposed models achieved 96.43% for liver segmentation, 95.51% for spleen segmentation, 92.65% for polyp segmentation, 94.11% for EM segmentation, 92.49% for nuclei segmentation, 91.81% for left atrium segmentation, and 87.27% for skin lesion segmentation. The experimental results showed that the proposed model was superior to the popular models for all seven applications, which demonstrates the high generality of the proposed model.

8 May 2023 in Electronics
Verified
Journal Article
Open access
PDF file
HLHai Minh Le
Hai Minh Le
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
Light Detection and Ranging (LiDAR) is a critical sensor for autonomous vehicle systems, providing high-resolution distance measurements in real-time. However, adverse weather conditions such as snow, rain, fog, and sun glare can affect LiDAR performance, requiring data preprocessing. This paper proposes a novel approach, the Adaptive Outlier Removal filter on range Image (AORI), which combines a projection image from LiDAR point clouds with an adaptive outlier removal filter to remove snow particles. Our research aims to analyze the characteristics of LiDAR and propose an image-based approach derived from LiDAR data that addresses the limitations of previous studies, particularly in improving the efficiency of nearest neighbor point search. Our proposed method achieves outstanding performance in both accuracy (>96%) and processing speed (0.26 s per frame) for autonomous driving systems under harsh weather from raw LiDAR point clouds in the Winter Adverse Driving dataset (WADS). Notably, AORI outperforms state-of-the-art filters by achieving a 6.6% higher F1 score and 0.7% higher accuracy. Although our method has a lower recall than state-of-the-art methods, it achieves a good balance between retaining object points and filter noise points from LiDAR, indicating its promise for snow removal in adverse weather conditions.

3 December 2019 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
DKDinh Thai Kim
Dinh Thai Kim
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
KLKai Che Jack Liu
Kai Che Jack Liu
WHWayne Shih Wei Huang
Wayne Shih Wei Huang
Purpose: The minimally invasive surgery (MIS) has shown advantages when compared to traditional surgery. However, there are two major challenges in the MIS technique: the limited field of view (FOV) and the lack of depth perception provided by the standard monocular endoscope. Therefore, in this study, we proposed a New Endoscope for Panoramic-View with Focus-Area 3D-Vision (3DMISPE) in order to provide surgeons with a broad view field and 3D images in the surgical area for real-time display.Method: The proposed system consisted of two endoscopic cameras fixed to each other. Compared to our previous study, the proposed algorithm for the stitching videos was novel. This proposed stitching algorithm was based on the stereo vision synthesis theory. Thus, this new method can support 3D reconstruction and image stitching at the same time. Moreover, our approach employed the same functions on reconstructing 3D surface images by calculating the overlap region’s disparity and performing image stitching with the two-view images from both the cameras.Results: The experimental results demonstrated that the proposed method can combine two endoscope’s FOV into one wider FOV. In addition, the part in the overlap region could also be synthesized for a 3D display to provide more information about depth and distance, with an error of about 1 mm. In the proposed system, the performance could achieve a frame rate of up to 11.3 fps on a single Intel i5-4590 CPU computer and 17.6 fps on a computer with an additional GTX1060 Nvidia GeForce GPU. Furthermore, the proposed stitching method in this study could be made 1.4 times after when compared to that in our previous report. Besides, our method also improved stitched image quality by significantly reducing the alignment errors or “ghosting” when compared to the SURF-based stitching method employed in our previous study.Conclusion: The proposed system can provide a more efficient way for the doctors with a broad area of view while still providing a 3D surface image in real-time applications. Our system give promises to improve existing limitations in laparoscopic surgery such as the limited FOV and the lack of depth perception.

21 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
HLHai Minh Le
Hai Minh Le
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
TNThanh-Tuan Nguyen
Thanh-Tuan Nguyen
Light Detection And Ranging (LiDAR) is an important technology integrated into self-driving cars to enhance the reliability of these systems. Even with some advantages over cameras, it is still limited under extreme weather conditions such as heavy rain, fog, or snow. Traditional methods such as Radius Outlier Removal (ROR) and Statistical Outlier Removal (SOR) are limited in their ability to detect snow points in LiDAR point clouds. This paper proposes an Adaptive Group of Density Outlier Removal (AGDOR) filter that can remove snow particles more effectively in raw LiDAR point clouds, with verification on the Winter Adverse Driving Dataset (WADS). In our proposed method, an intensity threshold combined with a proposed outlier removal filter was employed. Outstanding performance was obtained, with higher accuracy up to 96% and processing speed of 0.51 s per frame in our result. In particular, our filter outperforms the state-of-the-art filter by achieving a 16.32% higher Precision at the same accuracy. However, our method archive is lower in recall than the state-of-the-art method. This clearly indicates that AGDOR retains a significant amount of object points from LiDAR. The results suggest that our filter would be useful for snow removal under harsh weathers for autonomous driving systems.

27 May 2013 in VLSI Design
Verified
Journal Article
Open access
PDF file
YHYu-Ming Hsiao
Yu-Ming Hsiao
MSMiin-Shyue Shiau
Miin-Shyue Shiau
KLKuen-Han Li
Kuen-Han Li
JHJing-Jhong Hou
Jing-Jhong Hou
HHHeng-Shou Hsu
Heng-Shou Hsu
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
A CMOS amplifier with differential input and output was designed for very high common-mode rejection ratio (CMRR) and low offset. This design was implemented by the 0.35 μm CMOS technology provided by TSMC. With three stages of amplification and by balanced self-bias, a voltage gain of 80 dB with a CMRR of 130 dB was achieved. The related input offset was as low as 0.6 μV. In addition, the bias circuits were designed to be less sensitive to the power supply. It was expected that the whole amplifier was then more independent of process variations. This fact was confirmed in this study by simulation. With the simulation results, it is promising to exhibit an amplifier with high performances for biomedical applications.