Objective: The aim was to evaluate and optimize the performance of sensor monitors in measuring PM2.5 and PM10 under typical emission scenarios both indoors and outdoors. Method: Parallel measurements and comparisons of PM2.5 and PM10 were carried out between sensor monitors and standard instruments in typical indoor (2 months) and outdoor environments (1 year) in Shanghai, respectively. The optimized validation model was determined by comparing six machining learning models, adjusting for meteorological and related factors. The intra- and inter-device variation, measurement accuracy, and stability of sensor monitors were calculated and compared before and after validation. Results: Indoor particles were measured in a range of 0.8–370.7 μg/m3 and 1.9–465.2 μg/m3 for PM2.5 and PM10, respectively, while the outdoor ones were in the ranges of 1.0–211.0 μg/m3 and 0.0–493.0 μg/m3, correspondingly. Compared to machine learning models including multivariate linear model (ML), K-nearest neighbor model (KNN), support vector machine model (SVM), decision tree model (DT), and neural network model (MLP), the random forest (RF) model showed the best validation after adjusting for temperature, relative humidity (RH), PM2.5/PM10 ratios, and measurement time lengths (months) for both PM2.5 and PM10, in indoor (R2: 0.97 and 0.91, root-mean-square error (RMSE) of 1.91 μg/m3 and 4.56 μg/m3, respectively) and outdoor environments (R2: 0.90 and 0.80, RMSE of 5.61 μg/m3 and 17.54 μg/m3, respectively), respectively. Conclusions: Sensor monitors could provide reliable measurements of PM2.5 and PM10 with high accuracy and acceptable inter and intra-device consistency under typical indoor and outdoor scenarios after validation by RF model. Adjusting for both climate factors and the ratio of PM2.5/PM10 could improve the validation performance.
Parabens, a prevalent class of endocrine-disrupting chemicals (EDCs), are ubiquitous in consumer products; however, their role in linking pediatric allergic phenotypes remains poorly understood. This case-control study analyzed paraben levels in urine and indoor dust as proxies for internal and external exposures and investigated their associations with allergic rhinitis only (AR Only), asthma only (AS Only), and comorbidities (AR&AS) among children in Shanghai. The concentrations for each of four paraben compounds were quantitatively measured, and multi-pollutant frameworks—including Bayesian Kernel Machine Regression (BKMR) and Weighted Quantile Sum (WQS) regression—were employed to characterize the mixture exposure and risk. Propylparaben (PrP) was detectable in 100% of urine samples and over 90% of dust samples, and the concentrations ranked the highest out of the four compounds in both samples. Benzylparaben (BzP) was detected in >70% of urine samples and over 50% of dust samples at relatively lower levels. Urinary PrP exhibited significantly positive associations with all phenotypes (OR in 2.18–2.92) and BzP with the AR&AS Comorbidity (OR = 3.55, 95% CI: 1.32–9.55). Dust-borne PrP was associated with AR Only (OR = 2.26, 95% CI: 1.16–4.43), indicating a potential “Portal of Entry” effect via direct nasal deposition. According to BKMR and WQS analyses, urinary PrP and BzP emerged as two primary risk drivers. Using interaction analysis, an additive synergistic effect was observed between urinary PrP and BzP with parental history of allergy, suggesting heightened vulnerability to paraben exposure in genetically predisposed subgroups. In conclusion, children with respiratory allergies were associated with higher exposure to PrP and BzP and exhibited higher susceptibility in those with a parental history of allergy.