Manuel Gutiérrez-Capitán

Dr. Manuel Gutiérrez-Capitán


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2007 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
SASalvador Alegret
Salvador Alegret
Manel Del ValleManel Del Valle
Manel Del Valle

1 June 2012 in Analytica Chimica Acta
Verified
Journal Article
Open access
XCXavier Cetó
Xavier Cetó
Juan Manuel GutiérrezJuan Manuel Gutiérrez
Juan Manuel Gutiérrez
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
FCFrancisco Céspedes
Francisco Céspedes
JCJosefina Capdevila
Josefina Capdevila
Manel Del ValleManel Del Valle
Manel Del Valle
This work reports the application of a voltammetric electronic tongue system (ET) made from an array of modified graphite-epoxy composites plus a gold microelectrode in the qualitative and quantitative analysis of polyphenols found in wine. Wine samples were analyzed using cyclic voltammetry without any sample pretreatment. The obtained responses were preprocessed employing discrete wavelet transform (DWT) in order to compress and extract significant features from the voltammetric signals, and the obtained approximation coefficients fed a multivariate calibration method (artificial neural network-ANN-or partial least squares-PLS-) which accomplished the quantification of total polyphenol content. External test subset samples results were compared with the ones obtained with the Folin-Ciocalteu (FC) method and UV absorbance polyphenol index (I(280)) as reference values, with highly significant correlation coefficients of 0.979 and 0.963 in the range from 50 to 2400 mg L(-1) gallic acid equivalents, respectively. In a separate experiment, qualitative discrimination of different polyphenols found in wine was also assessed by principal component analysis (PCA).

11 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
ABAntonio Baldi
Antonio Baldi
Cesar Fernandez-SanchezCesar Fernandez-Sanchez
Cesar Fernandez-Sanchez
In healthcare, new diagnostic tools that help in the diagnosis, prognosis, and monitoring of diseases rapidly and accurately are in high demand. For in-situ measurement of disease or infection biomarkers, point-of-care devices provide a dramatic speed advantage over conventional techniques, thus aiding clinicians in decision-making. During the last decade, paper-based analytical devices, combining paper substrates and electrochemical detection components, have emerged as important point-of-need diagnostic tools. This review highlights significant works on this topic over the last five years, from 2015 to 2019. The most relevant articles published in 2018 and 2019 are examined in detail, focusing on device fabrication techniques and materials applied to the production of paper fluidic and electrochemical cell architectures as well as on the final device assembly. Two main approaches were identified, that are, on one hand, those ones where the fabrication of the electrochemical cell is done on the paper substrate, where the fluidic structures are also defined, and, on the other hand, the fabrication of those ones where the electrochemical cell and liquid-driving paper component are defined on different substrates and then heterogeneously assembled. The main limitations of the current technologies are outlined and an outlook on the current technology status and future prospects is given.

1 January 2014 in Analytica Chimica Acta
Verified
Journal Article
Closed access
VGVera L.V. Granado
Vera L.V. Granado
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
Cesar Fernandez-SanchezCesar Fernandez-Sanchez
Cesar Fernandez-Sanchez
Maria Teresa S.R. GomesMaria Teresa S.R. Gomes
Maria Teresa S.R. Gomes
Alisa RudnitskayaAlisa Rudnitskaya
Alisa Rudnitskaya
Cecilia Jimenez-JorqueraCecilia Jimenez-Jorquera
Cecilia Jimenez-Jorquera

1 May 2007 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
SAS. Alegret
S. Alegret
RRRafaela Cáceres Reyes
Rafaela Cáceres Reyes
JCJ. Casadesús
J. Casadesús
OMO. Marfà
O. Marfà
Manel Del ValleManel Del Valle
Manel Del Valle

1 December 2013 in Food Chemistry
Verified
Journal Article
Open access
XCXavier Cetó
Xavier Cetó
MGManuel Gutiérrez-Capitán
Manuel Gutiérrez-Capitán
DCDaniel Calvo
Daniel Calvo
Manel Del ValleManel Del Valle
Manel Del Valle
In this work, an electronic tongue (ET) system based on an array of potentiometric ion-selective electrodes (ISEs) for the discrimination of different commercial beer types is presented. The array was formed by 21 ISEs combining both cationic and anionic sensors with others with generic response. For this purpose beer samples were analyzed with the ET without any pretreatment rather than the smooth agitation of the samples with a magnetic stirrer in order to reduce the foaming of samples, which could interfere into the measurements. Then, the obtained responses were evaluated using two different pattern recognition methods, principal component analysis (PCA), which allowed identifying some initial patterns, and linear discriminant analysis (LDA) in order to achieve the correct recognition of sample varieties (81.9% accuracy). In the case of LDA, a stepwise inclusion method for variable selection based on Mahalanobis distance criteria was used to select the most discriminating variables. In this respect, the results showed that the use of supervised pattern recognition methods such as LDA is a good alternative for the resolution of complex identification situations. In addition, in order to show an ET quantitative application, beer alcohol content was predicted from the array data employing an artificial neural network model (root mean square error for testing subset was 0.131 abv).