It is well known that the amount of damage caused by lightning strikes to protected composite airframe structures depends on the paint characteristics, often applied on the surface of composite structures to protect from environmental effects and to personalise a product. In this work, physically based models of the mechanical loads induced by lightning strikes are employed in the generation of the mechanical overpressure fields due to a simulated lightning strike, while accounting for the paint thickness. These fields are then implemented into a three-dimensional finite element framework and combined with a damage model to predict the effect of paint thickness on the mechanical damage in composite structures subjected to this type of events. These models accurately predict the increase of damage extent with the increase of paint thickness, which is corroborated by experimental observations from industry and by the experimentally observed trends reported in literature.
In protected carbon fibre-reinforced polymer laminates subjected to simulated lightning strike, while thermal effects mostly affect the topmost UD plies, damage in the bulk, where temperatures can be far from the ablation temperatures of the composite constituents, is mainly the result of the explosion of the lightning protection layer, the supersonic plasma expansion shock waves, and the magnetic forces. In this work, previously validated three-dimensional models are applied to the analysis of lay-up and stacking sequence effects on the mechanical damage induced by simulated lightning strike on carbon/epoxy multi-directional laminates and compared with experimental observations in the literature. This work demonstrates that those observations can be replicated by the proposed models, predicting the effect of lay-up and stacking sequence not only on the orientation of mechanical damage, but also on its size. In addition, no effect on damage depth is predicted, which is also in agreement with available experimental observations. Finally, the models predict that laminates with thicker ply blocks have larger mechanical damage projected areas, which is also in agreement with experimental observations in the literature. While the previous literature had focused on the effect of the lay-up and stacking sequence on thermally induced damage, this work is a first attempt to predict those effects on the mechanical resistance, which in the future will be key to assessing lightning damage tolerance in protected composite laminates.