Karl-Villem Võsa

Mr. Karl-Villem Võsa


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
KVKarl-Villem Võsa
Karl-Villem Võsa
Andrea FerrantelliAndrea Ferrantelli
Andrea Ferrantelli
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Climate change has brought a compelling need for cooling living spaces to the attention of researchers as well as construction professionals. The problem of overheating enclosures is now exacerbated in traditionally affected areas and is also affecting countries that were previously less prone to the issue. In this paper, we address measurements of thermal comfort and cooling emission efficiency parameters for different devices: ceiling panels, underfloor cooling, fan-assisted radiators, and fan coil. These devices were tested in low and high cooling capacities of up to 40 W/m2 while also featuring heating dummies to imitate internal heat gains. Air temperatures were measured at different heights, allowing to evaluate the thermal stratification with high accuracy. Thermal comfort differences of the tested systems were quantified by measuring both air velocities and operative temperatures at points of occupancy. In summary, the best-performing cooling devices for the studied cooling applications were the ceiling panels and fan radiators, followed by underfloor cooling, with a limitation of stratification. Because of the strong jet, fan coil units did not achieve thermal comfort within the whole occupied zone. The results can be utilized in future studies for cooling emission efficiency and energy consumption analyses of the different cooling devices.

29 March 2021
Verified
Conference Paper
Open access
PDF file
KVKarl-Villem Võsa
Karl-Villem Võsa
AFAndrea Ferrantelli
Andrea Ferrantelli
DTDragomir Tzanev
Dragomir Tzanev
KSKamen Simeonov
Kamen Simeonov
PCPablo Carnero
Pablo Carnero
JKJarek Kurnitski
Jarek Kurnitski
In the current implementation of EPC-s, the assessment focus is purely on the energy consumption data. For the next generation of EPC-s, new performance indicators are proposed to address relevant building performance aspects, such as sustainability, productivity and market value. These indicators would enable evidence-based decision-making processes and facilitate the delivery of renovation triggers. Within the EPC framework, the problem is not the availability of such performance indicators, but the assessment effort required. Only easily available data can justifiably be introduced to bulk EPC-s, either as direct complementary input or as a performance indicator. Availability of such data was analysed from case studies that included EPC-s from 11 EU member states, mainly non-residential buildings. Analysed data included relevant HVAC information such as ventilation air flows, heating and cooling set-points and installed power, but also output data, such as EPC classes, net and primary energy need and GHG emissions. Based on our findings, we outlined two different development paths - one for existing buildings and one for new buildings and major renovations. Two categories of complementary indicators to energy are proposed – IEQ and power indicators.

3 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Andrea FerrantelliAndrea Ferrantelli
Andrea Ferrantelli
KVKarl-Villem Võsa
Karl-Villem Võsa
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Heat emitters, as the primary devices used in space heating, cover a fundamental role in the energy efficient use of buildings. In the search for an optimized design, heating devices should be compared with a benchmark emitter with maximum heat emission efficiency. However, such an ideal heater still needs to be defined. In this paper we perform an analysis of heat transfer in a European reference room, considering surface effects of thermal radiation and computing the induced operative temperature (op.t.) both analytically and numerically. Our ideal heater is the one determining the highest op.t. By means of functional optimization, we analyse trends such as the variation of operative temperature with radiator panel dimensions, finding optimal configurations. To make our definitions as general as possible, we address panel radiators, convectors, underfloor (UFH) and ceiling heater. We obtain analytical formulas for the operative temperature induced by panel radiators and identify the 10-type as our ideal radiator, while the UFH provides the best performance overall. Regarding specifically UFH and ceiling heaters, we find optimal sizes providing maximum op.t. The analytical method and qualitative results reported in this paper can be generalized and adopted in most studies concerning the efficiency of different heat emitter types in building enclosures.

16 June 2023 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
KVKarl-Villem Võsa
Karl-Villem Võsa
JKJarek Kurnitski
Jarek Kurnitski
CFClemens Felsmann
Clemens Felsmann
AMAndrea Meinsenbach
Andrea Meinsenbach
MCMichele De Carli
Michele De Carli
MIMikko Iivonen
Mikko Iivonen
Renovation of existing buildings has been highlighted as an essential action in the European Green Deal and in the latest revision of the EPBD to achieve energy efficiency targets. Renovation Wave strategy aims to double the deep energy renovation rate in EU by 2030, while specifically targeting the worst-performing segment of the existing building stock. The objective of this study was to assess the energy performance of deep renovation concepts on single and multi-family houses in three different geographical settings – Germany, Italy and Estonia. Typical German 1970s buildings were used as a baseline reference, and it was shown that very similar renovation concepts can be successfully applied across Europe that provides good bases to develop standardized solutions. Energy performance of two common renovation concepts was assessed both with national calculation methodologies and dynamic simulation with harmonized inputs and detailed heat pump plant models. The renovation concepts included improved envelope insulation and airtightness, switched to heat pump systems and heat recovery ventilation as well as incorporated on-site PV while complying with nearly zero-energy requirements for major renovations in all three countries. National energy calculation methodologies showed good accuracy for before the renovation situation but failed in many cases to calculate adequately NZEB renovation concepts with heat pumps and PV, indicating the development needs towards hourly calculation and more detailed treatment of heat pumps.

29 March 2021
Verified
Conference Paper
Open access
PDF file
KVKarl-Villem Võsa
Karl-Villem Võsa
AFAndrea Ferrantelli
Andrea Ferrantelli
JKJarek Kurnitski
Jarek Kurnitski
This paper investigates the interaction of a radiator’s thermal plume and downdraught of cold glazed surfaces. Draughts in working areas are one of the most common thermal comfort complaints in modern buildings. A typical solution for dealing with these draughts is positioning the heat emitters such as radiators or convectors under the windows. However, with thermally efficient envelopes, the internal loads compromise a relatively high fraction of the heating demand and the emitters are working under partial loads in modern buildings. This study comprises two parts: an experimental phase in the EN442 standardized test chamber with a 21-type radiator, and a CFD simulation phase, where the model is validated and applied under an expanded set of boundary conditions. The expanded simulation set results provide preliminary insight into sizing and design. More specifically, the thermal plume can be parametrised with a velocity and temperature value along with the room air and glazing temperatures for a broader analysis and assessment of the risk of draught.