Minghao Wen

Dr. Minghao Wen


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
YQYu Qin
Yu Qin
MWMinghao Wen
Minghao Wen
JZJunchao Zheng
Junchao Zheng
YBYu Bai
Yu Bai

20 March 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KHKe Han
Ke Han
YCYu Chen
Yu Chen
MWMinghao Wen
Minghao Wen
RMRuizhi Ma
Ruizhi Ma
The wide application of hybrid LCC/MMC HVDC system will be a trend in the future, and the performance of DC overhead line protection directly affects the safety of the system. The differential protection is used as backup protection to deal with high fault resistance conditions. However, it needs a long time delay to avoid mal-operation because of the distributed capacitance current. A new pilot protection scheme based on differential voltage is proposed in this paper to enhance the backup protection performance. In the proposed scheme, the compensated voltages at the setting points will be obtained from the measured voltage and current of the relay devices. The differential voltage at a setting point on the line is defined as the difference between the compensated voltages obtained by the rectifier-side relay devices and the inverter-side relay devices. The differential voltages are very tiny in external fault scenarios. Nevertheless, the differential voltages are large in internal fault scenarios. To improve the sensitivity and enhance protection performance, two setting points are set on the line. To simplify the calculation and ensure the calculation accuracy, the measured voltage and current are band-pass filtered. The proposed method has fast operation speed, simple calculation process, and can accurately estimate the fault distance. A ±800 kV hybrid LCC/MMC HVDC system is modelled in PSCAD/EMTDC to test the performance of the proposed scheme, and the effectiveness and reliability of it is verified.

9 February 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XWXingzhu Wang
Xingzhu Wang
YCYongxin Chen
Yongxin Chen
MWMinghao Wen
Minghao Wen
XYxg yin
xg yin
Microprocessor-based protective relay has risen to the ‘technology of choice’ with regard to power system protection due to its monitoring capability, self-checking capability, event recording capability, communication capability, capability for remote interrogation and setting application, and multiple setting groups. However, the existing Markov reliability model for protective relays does not reflect the state of the art of microprocessor-based relays. And the complexity of the Markov model limits its application in the wide range of relay studies. Therefore, this article establishes the general state-transition diagrams of protected components and relays, and a novel Markov model of a protection/component system by taking account of monitoring, self-checking, routine tests, common-cause failures, human error, operation of back-up protection, relay failure to operations and relay mal-trips. The study results of the sensitivity analysis and comparison analysis demonstrate the rationality and superiority of the novel model.

25 June 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BLBaowei Li
Baowei Li
MWMinghao Wen
Minghao Wen
XSXin Shi
Xin Shi
LWLi Wang
Li Wang
YCYu Chen
Yu Chen
The Rogowski coil transducer's integrator will amplify the transmission error, which may lead to mal-operation of the relay. In this paper, a novel method of line relay based on the differential output of Rogowski coil is proposed. Besides, an improved fast distance relay based on the differential output of Rogowski coil is presented. Based on the equal transfer process of transmission lines(ETPTL), the voltage signal should be processed by the virtual Rogowski coil to solve the inconsistent transfer problem between voltage and current. Furthermore, this paper also presents the reconstruction method of voltage at the fault point and the least-square algorithm to solve the R-L differential equation, so as to improve the algorithm accuracy. Furthermore, the equal transfer process error of the virtual Rogowski coil is analyzed in the paper, and the design principle of low pass filter is also proposed. Simulation results and experiment results demonstrate that the improved fast distance relay scheme has high operation speed, which is signed prior to other distance relay schemes. The proposed method also provides a valuable reference for other types of transmission line relay based on Rogowski coil transducer.

4 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
MWMinghao Wen
Minghao Wen
ZWZhen Wang
Zhen Wang
XYxg yin
xg yin
DCDeshu Chen
Deshu Chen
In this article, an incremental quantities distance protection using Park's transformation is proposed to increase the operation speed of distance protection. Based on the instantaneous voltage in abc frame approximate linear distribution along the AC transmission lines, this article proves that instantaneous voltage in dq frame still satisfies the approximate linear distribution along the AC transmission line. Then, the d -axis voltage components of fault point and setting point are used to determine the internal and external faults. In order to ensure that the presented distance protection can be applied to all fault types, a virtual three-phase system construction method is also presented. The fault point voltage construction method and low-pass filter design method are also discussed. Finally, a typical AC transmission system is developed in PSCAD/EMTDC to verify the performance of the proposed distance protection under different fault conditions. Simulation results indicate that the proposed incremental quantities distance protection has fast operation speed under internal metallic fault conditions and high security under external fault conditions.

17 August 2024 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
RMRuizhi Ma
Ruizhi Ma
YCYu Chen
Yu Chen
MWMinghao Wen
Minghao Wen
KHKe Han
Ke Han