Costanza Rossi

Dr. Costanza Rossi


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2023 in Cornea
Verified
Journal Article
Open access
Giuseppe GiannaccareGiuseppe Giannaccare
Giuseppe Giannaccare
Giulia CocoGiulia Coco
Giulia Coco
CRCostanza Rossi
Costanza Rossi
MBMassimiliano Borselli
Massimiliano Borselli
ALAndrea Lucisano
Andrea Lucisano
Vincenzo ScorciaVincenzo Scorcia
Vincenzo Scorcia
Purpose: The aim of this study was to report the successful clinical outcome of recalcitrant neurotrophic keratopathy (NK) treated with insulin eye drops associated with therapeutic Hyper-CL soft contact lens (CL) (EyeYon Medical, Ness Ziona, Israel). Methods: This study is a case report. Results: A 40-year-old man was referred to our clinic for the management of severe recalcitrant NK developed after surgical and adjuvant radiotherapy treatment of adenoid cystic carcinoma of the nasal cavity with basicranial involvement. The patient presented with severe conjunctival hyperemia, a large (7 × 4 mm) central epithelial defect, corneal opacity and thinning, and deep corneal neovascularization. Unpreserved tear substitutes, vitamin A ointment, punctal plug, bandage CL, and autologous serum had been used for the previous 3 months without success. Patient was prescribed insulin eye drops (1 unit per mL), and therapeutic Hyper-CL soft CL was applied to increase the contact time between insulin eye drops and the corneal surface. Follow-up visits were performed at day 10 (T1) and day 20 (T2). A marked reduction in the epithelial defect size was noted at T1 and complete healing was reached at T2. Simultaneously, conjunctival hyperemia and corneal opacity markedly reduced over time with treatment. Conclusions: The combination of insulin eye drops and therapeutic Hyper-CL soft CL was effective in determining healing of recalcitrant NK not responsive to standard treatments and bandage CL. It is unclear whether the positive outcomes were determined by insulin eye drops, Hyper-CL, or the combination of both, and future randomized clinical trials are warranted to determine the contribution of each treatment.

1 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MBMassimiliano Borselli
Massimiliano Borselli
Mario Damiano ToroMario Damiano Toro
Mario Damiano Toro
CRCostanza Rossi
Costanza Rossi
ATAndrea Taloni
Andrea Taloni
RKRohan Khemlani
Rohan Khemlani
Giuseppe GiannaccareGiuseppe Giannaccare
Giuseppe Giannaccare
Purpose: We aimed to evaluate the feasibility of using a novel device, the Smart Eye Camera (SEC), for assessing tear meniscus height (TMH) after fluorescein staining and the agreement of the results with measurements obtained using standard slit lamp examination. Methods: TMH was assessed using both SEC and conventional slit lamp examination. The images were analyzed using the software ImageJ 1.53t (National Institutes of Health, Bethesda, MD, USA). A common measurement unit scale was established based on a paper strip, which was used as a calibration marker to convert pixels into metric scale. A color threshold was applied using uniform parameters for brightness, saturation, and hue. The images were then binarized to black and white to enhance the representation of the tear menisci. A 2 mm area around the upper and lower meniscus in the central eye lid zone was selected and magnified 3200 times to facilitate manual measurement. The values obtained using SEC were compared with those obtained with a slit lamp. Results: The upper and lower TMH values measured using the SEC were not statistically different from those obtained with a slit lamp (0.209 ± 0.073 mm vs. 0.235 ± 0.085, p = 0.073, and 0.297 ± 0.168 vs. 0.260 ± 0.173, p = 0.275, respectively). The results of Bland–Altman analysis demonstrated strong agreement between the two instruments, with a mean bias of −0.016 mm (agreement limits: −0.117 to 0.145 mm) for upper TMH and 0.031 mm (agreement limits: −0.306 to 0.368 mm) for lower TMH. Conclusions: The SEC demonstrated sufficient validity and reliability for assessing TMH in healthy eyes in a clinical setting, demonstrating concordance with the conventional slit lamp examination.

28 March 2024 in Hematology Reports
Verified
Journal Article
Open access
PDF file
CRCostanza Rossi
Costanza Rossi
ABAlessandro Buizza
Alessandro Buizza
GAGiuseppe Alessio
Giuseppe Alessio
MBMassimiliano Borselli
Massimiliano Borselli
ATAndrea Taloni
Andrea Taloni
Giuseppe GiannaccareGiuseppe Giannaccare
Giuseppe Giannaccare
Ocular complications can occur in up to 90% of patients with blood malignancies. Such complications range from direct infiltration to local hemostatic imbalance and treatment-related toxicity. This narrative review is based on a systematic computerized search of the literature conducted until January 2024 and examines the common ocular complications associated with blood cancers. Ocular complications from primary disease include mass effects from ocular adnexal lymphomas and intraocular lymphomas, with B-cell lymphomas accounting for 95% of primary ocular presentations. Secondary disease involvement from systemic hematological malignancies can lead to a wide range of ocular manifestations, such as leukemic retinopathy. Furthermore, toxicity from antineoplastic therapies and ocular graft versus host disease (oGVHD) after hematopoietic stem cell transplantation present additional risks to ocular health. In conclusion, ocular complications in blood cancer patients are an integral part of patient management, requiring regular ophthalmic evaluations and close collaboration between oncologists and ophthalmologists. Advances in therapy and an increased focus on early symptom recognition are essential for preserving vision and enhancing patient quality of life.

7 June 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SVSabrina Vaccaro
Sabrina Vaccaro
MBMassimiliano Borselli
Massimiliano Borselli
Giovanni ScaliaGiovanni Scalia
Giovanni Scalia
CRCostanza Rossi
Costanza Rossi
Mario Damiano ToroMario Damiano Toro
Mario Damiano Toro
Giuseppe GiannaccareGiuseppe Giannaccare
Giuseppe Giannaccare
Purpose: To assess the feasibility and the diagnostic accuracy of the new tool, DEvice© (AI, Rome, Italy), for screening patients with dry eye disease (DED). Methods: This study was performed at the University Magna Græcia of Catanzaro. Enrolled patients were classified as affected by DED (group 1) or not (group 2) using an already validated tool (Keratograph 5M, Oculus, Germany), evaluating the noninvasive keratograph breakup time (NIKBUT), tear meniscus height (TMH), meibomian gland loss (MGL), and bulbar redness. All the patients were then examined by means of DEvice©, which allowed the measurement of the relative humidity (RH) and temperature of the ocular surface. Symptoms were scored using the Ocular Surface Disease Index (OSDI) questionnaire. Results: Overall, 40 patients (17 males and 23 females, mean age 38.0 ± 17.1 years) were included: of these, 20 belonged to group 1 and the remaining 20 to group 2. Using Keratograph 5M, significant differences between groups 1 and 2 were detected for NIKBUT-first (respectively, 4.97 ± 1.85 vs. 13.95 ± 4.8 s; p < 0.0001) and for NIKBUT-average (10.55 ± 4.39 vs. 15.96 ± 4.08 s; p = 0.0003). No statistically significant changes were detected for TMH (p = 0.565), MGL (p = 0.051), and bulbar redness (p = 0.687). Using Device©, a statistically significant higher value of RH was found in group 1 compared to group 2 (respectively, 85.93 ± 10.63 vs. 73.05 ± 12.84%; p = 0.0049). A statistically significant correlation was found between RH and OSDI (r = 0.406; p = 0.009). The value RH showed a discriminating power to detect DED with an AUC = 0.782 (standard error 0.07264; 95% CI 0.6401–0.9249; p = 0.0022). Conclusions: The DEvice© can effectively discriminate DED patients from healthy subjects. The parameter RH showed good sensitivity, making this tool ideal for a fast and noninvasive DED screening.

20 April 2023 in Eye
Verified
Journal Article
Open access
PDF file
ALAndrea Lucisano
Andrea Lucisano
Vincenzo ScorciaVincenzo Scorcia
Vincenzo Scorcia
ATAndrea Taloni
Andrea Taloni
CRCostanza Rossi
Costanza Rossi
RGRaffaella Gioia
Raffaella Gioia
GGGiuseppe Giannaccare
Giuseppe Giannaccare
Objectives Visual and topographic outcomes of large (9.0 mm) versus conventional (8.0 mm) deep anterior lamellar keratoplasty (DALK) for the treatment of keratoconus (KC) were compared in relation to the different localization of the corneal ectasia (within or beyond the central 8.0 mm). Methods This is a retrospective, comparative case series. Preoperatively, the topographic extension of the conus was calculated by measuring the distance from the geometric center of the cornea and the outermost point of the corneal ectasia (ectasia <8.0 mm, group A; ectasia ≥8.0 mm, group B). DALK was performed using both small grafts (8.0 mm, group 1) and large grafts (9.0 mm, group 2). Best-corrected visual acuity and topographic astigmatism were evaluated preoperatively (T0) and postoperatively after complete suture removal (1 year, T1). Results Data from 224 eyes of 196 patients (mean age 37.6 ± 15.1 years) were evaluated. Topographic astigmatism improved from T0 to T1 (4.94 ± 2.92 diopters (D) [95% CI, 4.56–5.33] vs 4.19 ± 2.45 D [95% CI, 3.87–4.51], p = 0.001). There was no significant difference in postoperative topographic cylinder between group 1 and group 2 when considering eyes with corneal ectasia <8.0 mm (group 1 A, 4.15 ± 2.19 D [95% CI, 3.64–4.66] vs group 2 A, 3.65 ± 2.13 D [95% CI, 2.92–4.38], p = 0.14); conversely, the difference was significant considering eyes with corneal ectasia ≥8.0 mm (group 1B, 4.74 ± 2.90 D [95% CI, 4.09-5.38] vs group 2B, 3.68 ± 1.94 D [95% CI, 3.10–4.26], p = 0.02). Conclusions Large 9.0-mm DALK provided better anatomical outcomes compared to conventional 8.0-mm DALK, particularly in eyes with corneal ectasia extending beyond the central 8.0 mm.

Verified
Journal Article
Open access
PDF file
Giuseppe GiannaccareGiuseppe Giannaccare
Giuseppe Giannaccare
SVSabrina Vaccaro
Sabrina Vaccaro
MBMassimiliano Borselli
Massimiliano Borselli
CRCostanza Rossi
Costanza Rossi
GCGiovanna Carnovale-Scalzo
Giovanna Carnovale-Scalzo
Vincenzo ScorciaVincenzo Scorcia
Vincenzo Scorcia
(1) Background: Dry eye disease (DED) is a multifactorial ocular surface disease characterized by an imbalance in ocular surface homeostasis, and tear substitutes constitute the first line of treatment. The present study aimed to evaluate the changes in the signs and symptoms of patients with DED treated with a novel tear substitute containing the GlicoPro® complex. (2) Methods: Patients with DED not successfully responding to other tear substitutes were enrolled and treated with a novel ophthalmic solution (two drops four times daily). Patients were examined before starting the study treatment (T0) and after 30 (T1) and 60 (T2) days of treatment by means of Keratograph for the evaluation of the following: (i) tear meniscus height (TMH); (ii) noninvasive Keratograph break-up time (NIKBUT); (iii) bulbar redness; and (iv) infrared meibography. The SANDE questionnaire was administered to assess ocular discomfort symptoms. Analysis of the tear content of proenkephalin and Met/Leu-enkephalin was also performed. (3) Results: At T2, a significant improvement in NIKBUT first, average, and class, TMH, and SANDE score was found. The tear content of proenkephalins was significantly higher at T1, whereas processed active Met/Leu-enkephalins increased at both T1 and T2. (4) Conclusions: Our novel tear substitute based on GlicoPro® resulted in a significant improvement in ocular discomfort symptoms, tear volume, and stability in the patients treated. The increase in active peptides processed in tears may represent the pathophysiological substrate underlying this finding.