In view of optimizing the configuration of each unit’s capacity for energy storage in the microgrid system, in order to ensure that the planned energy storage capacity can meet the reasonable operation of the microgrid’s control strategy, the power fluctuations during the grid-connected operation of the microgrid are considered in the planning and The economic benefit of hybrid energy storage is quantified. A multi-objective function aiming at minimizing the power fluctuation on the DC bus in the microgrid and optimizing the capacity ratio of each energy storage system in the hybrid energy storage system (HESS) is established. The improved particle swarm algorithm (PSO) is used to solve the objective function, and the solution is applied to the microgrid experimental platform. By comparing the power fluctuations of the battery and the supercapacitor in the HESS, the power distribution is directly reflected. Comparing with the traditional mixed energy storage control strategy, it shows that the optimized hybrid energy storage control strategy can save 4.3% of the cost compared with the traditional hybrid energy storage control strategy, and the performance of the power fluctuation of the renewable energy is also improved. It proves that the proposed capacity configuration of the HESS has certain theoretical significance and practical application value.
In order to solve the problem of which the dynamic response of a supercapacitor (SC) is limited due to the mismatch dynamic characteristics between the DC/DC converter and supercapacitor in an energy storage system, this paper proposes a hybrid model predictive control strategy based on a dual active bridge (DAB). The hybrid model predictive control model considers the supercapacitor and DAB in a unified way, including the equivalent series resistance and capacitance parameters of the SC. The method can obtain a large charging and discharging current of the SC, thereby not only improving the overall response speed of the system, but also expanding the actual capacity utilization range of the SC. The simulation results show that compared with the model prediction method of the dual active bridge converter, the proposed control method can effectively improve the overall response speed of the system, which can be improved by at least 0.4 ms. In addition, the proposed method increases the actual upper limit of the SC voltage, reduces the actual lower limit of the SC voltage, and then expands the actual capacity utilization range of the SC by 18.63%. The proposed method has good application prospects in improving the dynamic response performance of energy storage systems.
22 June 2022 in IEEE Transactions on Power Electronics
This article presents an efficient and fast echelon battery equalization method based on wide voltage range bidirectional converter combined with DBSCAN (density-based spatial clustering of applications with noise) clustering control strategy. Thanks to the wide voltage range and bidirectional buck-boost characteristics of the four-switch bidirectional converter, the battery energy can be reasonably redistributed between the battery and the super capacitor. The converter operating in synchronous rectification mode can not only achieve bidirectional energy flow in a wide voltage range, but also has a high energy conversion efficiency. The DBSCAN clustering algorithm is used to divide all battery cells into groups, and each group may contain one or more adjacent and nonadjacent battery cells. First, the nonadjacent single cells are balanced and integrated into adjacent group with the closest voltage. Then, the groups with different voltages are balanced by group-to-group, thereby realizing rapid balance of the entire battery pack. In order to verify the effectiveness of the proposed method, simulations and experimental verification were carried out. The experimental results show that, comparing with traditional battery balancing methods, the proposed method achieves shorter balancing time and higher balancing efficiency.
Currently, using hybrid energy storage system composed of battery and supercapacitor to stabilize DC bus power fluctuation is a hot issue. In low-pass filtering control strategy to suppress the power fluctuation of DC bus, the filtering time constant is fixed, so there are problems such as poor load power fluctuation smoothing effect and over-charge and over-discharge of the battery. In this paper, a two-stage low-pass filter control strategy with variable filter time constant is designed. Firstly, the strategy builds a multi-objective function with minimum load slow target power and DC bus power difference. Using the Improved Particle Swarm Optimisation (IPSO) with compensating coefficient of inertia weight factor to solve the optimal output power by a hybrid energy storage system, and dynamically adjust the first-level filtering time constant, in order to reduce the load power change causing the fluctuation of the DC bus power; secondly, according to the charging state of the supercapacitor and the battery, the fuzzy control method is adapted to dynamically adjust the second-order filtering time constant to optimize the power distribution of the battery and the supercapacitor. The experimental results show that the control strategy can effectively reduce the power fluctuation of DC bus by about 15%, and avoid the over limit phenomenon of the battery state of charge, which has a good prospect of engineering application.
In order to solve the imminent problem in that the traditional protection strategy cannot meet time requirements, together with the fact that the rotational inertia of a DC microgrid is small and short-circuit fault develops rapidly, a bidirectional short-circuit current blocker (BSCCB) based on solid-state circuit breaker for a DC microgrid is proposed. Firstly, the bidirectional current blocking circuit structure is proposed based on the analysis of key components. Then, a top-level differential protection strategy is developed based on the aforementioned proposal. Finally, the performance of the blocking circuit is simulated and verified by experiments. The results show that the proposed method can block short-circuit current within 4 ms, and the response speed of the protection strategy is very fast compared with previous approaches. BSCCB also has reclosing, bidirectional blocking and energy releasing functions. The current blocker proposed in this paper can be reused multiple times and has a promising future in low-voltage DC microgrid application.
Traditional hierarchical control of the microgrid does not consider the energy storage status of a distributed hybrid energy storage system. This leads to the inconsistency of the remaining capacity of the energy storage system in the process of system operation, which is not conducive to the safe and stable operation of the system. In this paper, an improved hierarchical control strategy is proposed: the first allocation layer completes the allocation between the distribution energy storage systems considering the state of hybrid energy storage systems, and the second allocation layer realizes the allocation within the hybrid energy storage systems based on variable time constant low-pass filtering. Considering the extreme conditions of energy storage systems, the transfer current is introduced in the second allocation process. The SOC (stage of charge) of the supercapacitor is between 40% and 60%, which ensures that the supercapacitor has enough margin to respond to the power demand. An example of a 300 MW photovoltaic microgrid system in a certain area is analyzed. Compared with the traditional hierarchical control, the proposed control strategy can reduce the SOC change of a hybrid energy storage system by 9% under the same conditions, and make the supercapacitor active after power stabilization, which is helpful to the stable operation of the microgrid.