Maurizio Viviani

Dr. Maurizio Viviani

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MVMaurizio Viviani
Maurizio Viviani
Nicola Luigi BragazziNicola Luigi Bragazzi
Nicola Luigi Bragazzi
GBGaositwe Bolani
Gaositwe Bolani
SPSimonetta Papa
Simonetta Papa
Luca GiacomelliLuca Giacomelli
Luca Giacomelli
Roberto EggenhoffnerRoberto Eggenhoffner
Roberto Eggenhoffner
Forward osmosis (FO) membranes are commonly evaluated through macroscopic observables such as water flux and reverse solute flux. However, these quantities do not necessarily reveal whether water permeation and solute leakage remain governed by the same dominant transport pathways, particularly in heterogeneous nanostructured membranes where selective nanochannels and defect-mediated pores can contribute differently to solvent and solute transport. Here, we introduce a hierarchical diagnostic framework to assess transport coherence loss in heterogeneous FO membranes. The framework comprises a baseline model (BM), an extended model (EM) including chemistry–geometry coupling through accessibility loss, and a full model (FM) incorporating selective pore-size heterogeneity. The flux ratio R=Js/Jw is used as a regime-based diagnostic descriptor of transport organization, and its normalized form is used to map coherence variations across the state-space defined by structural selectivity and nanochemical state. The results show that chemistry–geometry coupling produces the first clear reorganization of the coherence landscape, whereas pore-size heterogeneity mainly broadens the response while preserving its dominant topology. Simulations based on both Monte Carlo and experimentally derived pore-size distributions show consistent trends. Overall, the BM–EM–FM hierarchy offers an interpretable framework for describing transport coherence loss and the emergence of leakage-prone regimes in heterogeneous FO membranes.

18 June 2026 in Membranes
Verified
Journal Article
Open access
PDF file
MVMaurizio Viviani
Maurizio Viviani
Nicola Luigi BragazziNicola Luigi Bragazzi
Nicola Luigi Bragazzi
GBGaositwe Bolani
Gaositwe Bolani
SPSimonetta Papa
Simonetta Papa
Luca GiacomelliLuca Giacomelli
Luca Giacomelli
Roberto EggenhoffnerRoberto Eggenhoffner
Roberto Eggenhoffner
Forward osmosis (FO) membranes are commonly evaluated through macroscopic observables such as water flux and reverse solute flux. However, these quantities do not necessarily reveal whether water permeation and solute leakage remain governed by the same dominant transport pathways, particularly in heterogeneous nanostructured membranes where selective nanochannels and defect-mediated pores can contribute differently to solvent and solute transport. Here, we introduce a hierarchical diagnostic framework to assess transport coherence loss in heterogeneous FO membranes. The framework comprises a baseline model (BM), an extended model (EM) including chemistry–geometry coupling through accessibility loss, and a full model (FM) incorporating selective pore-size heterogeneity. The ratio of reverse solute flux to water flux RJ=Js/Jw is used as a regime-based diagnostic descriptor of transport organisation, while its normalised form maps coherence variations across the state-space defined by structural selectivity and nanochemical state. The results show that chemistry–geometry coupling produces the first clear reorganisation of the coherence landscape, whereas pore-size heterogeneity mainly broadens the response while preserving its dominant topology. Simulations based on both Monte Carlo and experimentally derived pore-size distributions show consistent trends. Overall, the BM–EM–FM hierarchy offers an interpretable framework for describing transport coherence loss and the emergence of leakage-prone regimes in heterogeneous FO membranes.

13 October 2026 in Membranes
Verified
Journal Article
Open access
PDF file
MVMaurizio Viviani
Maurizio Viviani
Nicola Luigi BragazziNicola Luigi Bragazzi
Nicola Luigi Bragazzi
SPSimonetta Papa
Simonetta Papa
Luca GiacomelliLuca Giacomelli
Luca Giacomelli
Roberto EggenhoffnerRoberto Eggenhoffner
Roberto Eggenhoffner
Forward osmosis (FO) membrane performance is commonly described through water flux Jw, reverse-solute flux Js, and the specific reverse-solute ratio RJ = Js/Jw. These observables provide a low-dimensional projection of a coupled transport system where selective-layer permeability, support resistance, concentration polarization, and defect-mediated leakage interact, producing non-unique links between membrane organization and measured performance. The objective of this study is to determine to what extent the commonly reported FO observables Jw, Js, and RJ can constrain the underlying transport mechanisms, and to quantify the residual ambiguity when different combinations of selective-layer permeability, support resistance, concentration polarization, and defect-mediated leakage remain compatible with the same measured response. To address this objective, the study develops an admissible-inference framework in the experimentally accessible (Jw, RJ) plane, where published FO measurements are analyzed through observable-space mapping, concentration-polarization amplification, covariance-rank analysis, Fisher/SVD sensitivity diagnostics, and admissible-volume mapping. The resulting framework determines which transport interpretations remain compatible with the observations and which mechanistic directions require additional independent measurements to be resolved.