Electrical quantities such as Voltage, Current, Power, Power Factor, Energy, and Frequency in electrical power system tends to fluctuate, as a result of load changes, disturbances, or other abnormal states. The change-state in electrical quantities should be identify immediately, otherwise it can lead to serious problem for whole system. Therefore a necessity is required to determine the condition of electricity change-state quickly and appropriately in order to make effective decisions. Online monitoring of power distribution system based on Internet of Things (IoT) technology was deploy and implemented on Department of Mechanical Engineering University of Lampung (Unila), especially at three-phase main distribution panel H-building. The measurement system involve multiple sensors such current sensors and voltage sensors, while data processing conducted by Arduino, the measurement data stored in to the database server and shown in a real-time through a web-based application. This measurement system has several important features especially for realtime monitoring, robust data acquisition and logging, system reporting, so it will produce an important information that can be used for various purposes of future power analysis such estimation and planning. The result of this research shown that the condition of electrical power system at H-building performed unbalanced load, which often leads to drop-voltage condition
31 December 2019 in Jurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems)
Kerusakan pada transformator distribusi dapat mengganggu kontinuitas pengiriman daya listrik ke konsumen. Berbagai gangguan dapat mengakibatkan kerusakan pada transformator distribusi sehingga monitoring besaran listrik dari transformator distribusi perlu dilakukan. Makalah ini menyajikan sistem monitoring besaran-besaran listrik dari transformator distribusi secara online berbasis teknologi internet of things (IoT). Sensor tegangan dan sensor arus digunakan untuk mengukur tegangan dan arus, mikrokontroler digunakan sebagai pemrosesan data hasil pengukuran dan ethernet shield  serta modem internet digunakan untuk mengirimkan data ke server platform IoT Ubidots. Hasil pengujian menunjukkan alat monitoring transformator distribusi mampu bekerja untuk memonitor besaran-besaran listrik transformator distribusi dan mengirimkan data ke jaringan penyedia IoT sehingga dapat dimonitor dari jarak yang jauh melalui perangkat laptop atau handphone. Â
University is an organization that obliged to provide higher education, research, and community service (Tri Dharma), it has autonomy to manage their institutions. In order to realize Tri Dharma, University should made a planning of information technology (IT) infrastructure to support alignment process between organization business strategy and IT strategy. University of Lampung (Unila) as a government university in Lampung Province, already had IT infrastructure and managed by special unit. IT management on Unila nowadays more complicated, disintegrated of IT management has an effect that IT infrastructure was not adaptive to response the quick change of business needs. This research aimed to design an adaptive IT infrastructure based on enterprise architecture framework The Open Group Architecture Framework (TOGAF) Architecture Development Method (ADM) on Unila. The results of this research found that there are 3 core business activities, and 6 supporting activities identified on this campus. We also proposed 12 application to developed, all applications should be modular and integrated with other.
Electricity network needs to be monitored, especially for Voltage (V) measurement, current (A), power factor (cos θ), power (W), and energy consumption (kWh). Monitoring is important, in order to know the quality of electricity supply in the system, identifying disruption events, and to calculate the amount of electrical energy consumption periodically. To achieve the objectives mentioned above, we have made device that can be monitor the electrical quantities in real time, recorded data was stored in to database system, and web application processed this data and shown the statistic reports through a web interface. This research was conducted on the 3 phase electricity at The Integrated Laboratory of the Electrical Engineering Department University of Lampung. Monitoring of voltage, current and energy consumption was done by using a step-down transformator as a voltage sensor, ACS712-30A as current sensors for capture the flow measurement, and TEM015-D4250 kWh meter for measuring energy consumption. Power and Power Factor value was obtained by some of scientific calculation. We used Python programming language for data processing measurement and calculation, running on BCM2835 Single Board Computer. The results of measurements include voltage, current, power factor, power, and the amount of energy consumption was stored in to data base, and data report can be accessed online using web browser.
30 October 2019 in International Journal of Engineering and Advanced Technology
A university usually has many Lecturers that have an important role in improving the quality of Higher Education. The Lecturers should produce scientific publications at least 1 publication on each semester. The achievements of a Lecturer in research and publication become the main indicator that describes the professionalism of lecturers as scientists. Monitoring the improvement of publication trends is very important to do as an evaluation for organizational management in choosing the best strategy to strengthen the quality of publication, and one of the common tools used for analyzing the publication data is the Google Scholar system. This paper attempts to analyze the Google scholar data using Data Mining techniques (Text Mining) by R language, to collect Lecturer’s profile and list of publications in a real-time, the aim of this research is to allow the Management for identifying the Cluster from total 1039 Lecturers on University of Lampung. The results of this research shown there were 5 Cluster of scholar profile data, with member details C0=102, C1=924, C2=1, C3=1, C4=11, total 88.93% of Lecturers are on cluster C1 with, centroid data was h_index=1.942, total_cites=20.89, i10_index=0.417.
10 December 2021 in Jurnal Informatika dan Teknik Elektro Terapan
Data Hujan merupakan parameter utama dalam menghitung debit andalan, banyaknya kendala dalam perhitungan tersebut, seperti minimnya ketersediaan data, data tidak lengkap/kosong, stasiun hujan tidak berada didalam daerah aliran sungai (DAS), pencatatan data masih manual, dan tidak tersedianya data muka air sungai/automatic water level recorder (AWLR). Untuk mengatasi permasalahan tersebut, dapat digunakan data satelit hujan yang memiliki resolusi spasial dan temporal tinggi, cakupan wilayah luas, data near real-time, akses cepat, dan ekonomis. Penelitian ini dilakukan untuk validasi dan koreksi data satelit Tropical Rainfall Measuring Mission (TRMM) terhadap data observasi pada DAS Way Andeng. Analisis dilakukan menggunakan analisis statistika, perhitungan galat dan pengembangan faktor koreksi untuk data satelit TRMM. Provinsi Lampung memiliki pola hujan monsun. Hasil validasi data satelit TRMM terhadap data observasi menunjukkan nilai korelasi tinggi di wilayah pola monsun (>0,80). Nilai root mean square error (RMSE) lebih rendah di wilayah pola hujan monsun (RMSE = 58-84). Das Way Andeng memiliki luas = 18,57 km2 dan tidak memiliki stasiun hujan yang berada didalam DAS, letak staiun hujan pos hujan (PH) 030 berada diluar DAS ±10 km. Sumber air baku dari Way andeng sangat diperlukan untuk Kecamatan Bakauheni, Pelabuhan Bakauheni, dan Menara Siger di Kabupaten Lampung Selatan. Untuk mengetahui ketersediaan air di masa yang akan datang diperlukan analisis perhitungan debit andalan Q90 Sungai Way andeng dengan metode F.J MOCK, pengertian Q90 adalah kemungkinan terpenuhi ditetapkan 90%.