Juan Camean

Dr. Juan Camean


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2026 in Cancers
Verified
Journal Article
Open access
PDF file
NPNahuel Paesano
Nahuel Paesano
JCJuan Camean
Juan Camean
MRMaximiano Ringa
Maximiano Ringa
Maximiliano Lopez SilvaMaximiliano Lopez Silva
Maximiliano Lopez Silva
GKGuido Koren
Guido Koren
JMJuan Morote
Juan Morote
Objectives: To externally validate the Barcelona Predictive Models (BCN-PM 1 and 2) for detecting csPCa in an Ibero-American population. BCN-PM 1 was designed to reduce magnetic resonance imaging (MRI) use, whereas BCN-PM 2 aims to decrease unnecessary prostate biopsies. Methods: This prospective, multicenter study included 661 men with suspected PCa recruited in 2025 across three Ibero-American centers. All participants underwent MRI followed by targeted biopsies of lesions with the Prostate Imaging–Reporting and Data System (PI-RADS) ≥ 3, along with systematic biopsy. When PI-RADS lesions were <3, only systematic biopsies were performed. CsPCa was defined as International Society of Urological Pathology Grade Group ≥ 2. BCN-PM 1 incorporates age (years), family history of PCa (no vs. yes), prior negative prostate biopsy (no vs. yes), digital rectal examination (DRE: normal vs. suspicious), and prostate volume-derived estimation by DRE (small, median, or large). BCN-PM 2 includes age, family history of PCa, prior negative prostate biopsy, prostate volume measured by MRI (mL), and PI-RADS score (1–5). Results: The rate of csPCa detection was 53.7%. Both models demonstrated good calibration with strong agreement between predicted probabilities and observed csPCa rates. BCN-PM 1 closely followed the reference line, with minor deviations at higher predicted probabilities, whereas BCN-PM 2 showed modest departures at the extremes of risk. The area under the curve was 0.740 (95% CI 0.702–0.777) for BCN-PM 1 and 0.803 (95% CI 0.769–0.836) for BCN-PM 2 (p < 0.001). Decision curve analysis demonstrated a net benefit for both models compared with strategies of biopsy in all or no men. BCN-PM 2 showed greater net benefit than BCN-PM 1. At 95% sensitivity, BCN-PM 1 reduced MRI requests by 10.6%, while BCN-PM 2 avoided 19.4% of unnecessary biopsies. The sequential use of BCN-PM 1 and 2 resulted in a 10.6% reduction in MRI exams and a 23.1% reduction in biopsies, at the cost of missing 8.4% of csPCa cases. The performance of the biopsy improved from 53.7% to 64.0% (p < 0.001). Conclusions: BCN-PM1 and BCN-PM 2 were successfully validated in an Ibero-American population.