Travis Moore

Mr. Travis Moore


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
BZBahador Ziaeemehr
Bahador Ziaeemehr
Zahra JandaghianZahra Jandaghian
Zahra Jandaghian
Hua GeHua Ge
Hua Ge
MLMichael A. Lacasse
Michael A. Lacasse
TMTravis Moore
Travis Moore
The Urban Heat Island (UHI), a consequence of urban development, leads to elevated temperatures within cities compared to their rural counterparts. This phenomenon results from factors such as urban designs, anthropogenic heat emissions, and materials that absorb and retain solar radiation in the built environment. Materials commonly used in cities, like concrete, asphalt, and stone, capture solar energy and subsequently emit it as heat into the surroundings. Consequently, this phenomenon amplifies summertime cooling energy demands in buildings. To mitigate the UHI impacts, various mitigation strategies have emerged that include but are not limited to using higher solar reflectivity materials, known as “cool materials”, and increasing vegetation and greenery in urban areas. Cool materials have high reflectivity and emissivity, effectively reflecting solar radiation while emitting absorbed heat through radiative cooling. Increasing the solar reflectivity of building envelope materials is a promising sustainable solution to lessen the UHI effects. This state-of-the-art review summarizes the UHI causes and effects, states the mitigation strategies, describes the cool building envelope materials, explains the solar reflectivity index measurements, indicates the building and micro-climate simulations, highlights the performance evaluation of using cool building envelope materials, points out the research gaps, and proposes future research opportunities.

14 May 2024 in Energy and Buildings
Verified
Journal Article
Open access
SRSaeed Rayegan
Saeed Rayegan
LWLiangzhu (Leon) Wang
Liangzhu (Leon) Wang
Radu ZmeureanuRadu Zmeureanu
Radu Zmeureanu
AKAli Katal
Ali Katal
MMMohammad Mortezazadeh
Mohammad Mortezazadeh
YSYurong Shi
Yurong Shi

31 March 2023 in Forests
Verified
Journal Article
Open access
PDF file
MDMaurice Defo
Maurice Defo
Lin WangLin Wang
Lin Wang
MLMichael A. Lacasse
Michael A. Lacasse
TMTravis Moore
Travis Moore
A study was realized to assess the effects of historical and projected future climates on the hygrothermal performance of cross-laminated timber wall assemblies in 12 Canadian cities belonging to several climate regions and zones and for two cladding and ventilation types. Water ingress in the wall assembly was supposed to be 1% wind-driven rain (WDR), and the airflow rate in the drainage cavity was calculated using local climate data. The hygrothermal simulation results showed that under the assumption of no deficiencies allowing wind-driven rain to enter into the wall (perfect wall), there is no risk of mold growth in the future for both claddings, either vented or ventilated. Under the assumption of high moisture loads (1% WDR), the mold growth risk could increase significantly in all climate regions and cities considered. However, in those cities located in the Cordillera and Prairie regions, the increase was not found to be problematic as the maximum mold growth remained under the acceptable level, whereas for cities located in coastal and southeastern regions, the increase in mold growth risk could be considerable. The impacts of cladding and ventilation types on the relative performance of the walls varied with city location.

14 October 2021 in Buildings
Verified
Journal Article
Open access
PDF file
AKAytaç Kubilay
Aytaç Kubilay
JBJohn V Bourcet
John V Bourcet
JGJessica Gravel
Jessica Gravel
Xiaohai ZhouXiaohai Zhou
Xiaohai Zhou
TMTravis Moore
Travis Moore
DDDominique Derome
Dominique Derome
Parts of the building envelope that frequently receive high amounts of rain are usually exposed to a higher risk of deterioration due to moisture. Determination of such locations can thus help with the assessment of moisture-induced damage risks. This study performs computational fluid dynamics (CFD) simulations of wind-driven rain (WDR) on the Parliament buildings in Ottawa, Canada. Long-term time-varying wetting load due to WDR and potential evaporation are considered according to several years of meteorological data, and this cumulative assessment is proposed as a fast method to identify critical locations and periods. The results show that, on the Center Block of the Parliament buildings, the façades of lower towers facing east are the most exposed to WDR, together with the corners of the main tower. Periods of high WDR wetting load larger than the potential evaporation are observed, indicating that deposited rain may lead to moisture accumulation in the envelope. During these critical periods of up to several months, air temperature may repeatedly drop below freezing point, which poses a risk of freeze–thaw damage. First assessment on future freeze–thaw damage risks indicates an increase in such risks at moderate increases in temperature, but a lower risk is found for larger increases in temperature.

21 April 2023 in Journal of Building Physics
Verified
Journal Article
Open access
BSBenyamin Salehpour
Benyamin Salehpour
Mehdi GhobadiMehdi Ghobadi
Mehdi Ghobadi
HGHua Ge
Hua Ge
TMTravis Moore
Travis Moore
Reducing energy consumption and Greenhouse Gas (GHG) emissions is an essential part of the clean growth and climate change framework recently developed by the Canadian government, which emphasizes the importance of energy-efficient building constructions. In this paper, the effects of thermal mass and placement of the thermally massive layer within wall assemblies on the transient thermal performance of walls and energy performance of a case study office building were studied. Three climate conditions representative of the heating-dominated, temperate, and cooling-dominated climates were considered. As for the assessment of energy demands, two cases for the indoor air temperature were taken into account: (i) indoor temperature was maintained at 20°C throughout the year, and (ii) during summertime, there was a set-point of 24°C and a setback of 35°C during the rest of the day while during wintertime, the set-point and setback values were 22°C and 18°C, respectively. The cases were compared according to the resulting decrement factor, the time required to reach quasi-steady state conditions, amplitudes of changes of heat fluxes and indoor surface temperatures, and the energy demands. The results showed that, for the cases studied, the wall, for which the thermally massive layer is not directly exposed to the indoor and outdoor climate conditions, resulted in the lowest decrement factor, the minimum amplitude of changes of heat fluxes and indoor surface temperatures, and maximum time required to reach quasi steady-state conditions. As for the energy performance, on the other hand, the wall, for which the thermally massive layer is exposed to the interior and exterior climate conditions, performed best amongst the cases investigated.

27 December 2020 in Journal of Building Physics
Verified
Journal Article
Closed access
PDF file
TMTravis Moore
Travis Moore
CCCynthia Ann Cruickshank
Cynthia Ann Cruickshank
IBIan Beausoleil-Morrison
Ian Beausoleil-Morrison
MLMichael A. Lacasse
Michael A. Lacasse
The purpose of this paper is to investigate the potential for calculation methods to determine the thermal resistance of a wall system containing vacuum insulation panels (VIPs) that has been experimentally characterised using a guarded hot box (GHB) apparatus. The VIPs used in the wall assembly have not been characterised separately to the wall assembly, and therefore exact knowledge of the thermal performance of the VIP including edge effect is not known. The calculations and simulations are completed using methods found in literature as well as manufacturer published values for the VIPs to determine the potential for calculation and simulation methods to predict the thermal resistance of the wall assembly without the exact characterisation of the VIP edge effect. The results demonstrate that disregarding the effect of VIP thermal bridges results in overestimating the thermal resistance of the wall assembly in all calculation and simulation methods, ranging from overestimates of 21% to 58%. Accounting for the VIP thermal bridges using the manufacturer advertised effective thermal conductivity of the VIPs resulted in three methods predicting the thermal resistance of the wall assembly within the uncertainty of the GHB results: the isothermal planes method, modified zone method and the 3D simulation. Of these methods only the 3D simulation can be considered a potential valid method for energy code compliance, as the isothermal planes method requires too drastic an assumption to be valid and the modified zone method requires extrapolating the zone factor beyond values which have been validated. The results of this work demonstrate that 3D simulations do show potential for use in lieu of guarded hot box testing for predicting the thermal resistance of wall assemblies containing both VIPs and steel studs. However, knowledge of the VIP effective thermal conductivity is imperative to achieve reasonable results.