ABIR BOUAOUN

Dr. ABIR BOUAOUN

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2018 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
ABABIR BOUAOUN
ABIR BOUAOUN
LOLatifa Ben Omrane
Latifa Ben Omrane
MMMohamed Mogaadi
Mohamed Mogaadi
WKWièm Douira Khomsi
Wièm Douira Khomsi
AZAsma Zidi
Asma Zidi
AHAzza Hammou
Azza Hammou
The purpose of this study was to assess and analyze the radiation doses during head pediatric CT from different CT units within six Tunisian hospitals representing different geographic regions in order to optimize the dose given and minimize the radiology risk to this category of patients and towards the derivation of national diagnostic reference levels. Patient data and exposure parameters were collected for four age groups (<1, 1–5, 5–10 and 10–15 y). Clinical protocols and exposure settings were analyzed. Doses were collected in terms of CTDIvol and DLP values. Effective and Organ doses to specific radiosensitive organs were estimated using the Monte Carlo simulation software ‘Impact CTDosimetry’. Results showed large variations in CT protocols and doses between different radiology departments. CTDIvol and DLP values demonstrated a broad range between the CT units and between the axial and helical scan techniques in the same unit. CTDI vol values were estimated to be 24.9, 31.7, 45.5 and 47.8 mGy for <1, 1–5, 5–10 and 10–15 y age groups, respectively. In term of DLP, median values were ~346, 528, 824, 897 mGy cm for the same age groups, respectively. Effective dose ranged from 1.4 to 5 mSv. Dose values were comparable with those reported in the literature. The study shows an evident need for continuous training of staff in radiation protection concepts, especially within the regional hospitals, emphasizes the importance of the production and the update of recommendations and good practice guidelines using interdisciplinary working groups and opens the way for the establishment of national DRLs.

11 July 2022 in Journal of Radiological Protection
Verified
Journal Article
Closed access
ABABIR BOUAOUN
ABIR BOUAOUN
LOLatifa Ben Omrane
Latifa Ben Omrane
WKWièm Douira Khomssi
Wièm Douira Khomssi
This work focuses on the determination of the radiation doses for a total sample of 916 children, categorised into four age groups (<1, 1–5, <5–10, <10–15 years) undergoing the most frequent paediatric CT scans performed in different scan facilities in Tunisia in order to establish the national diagnostic reference levels (DRLs). Dose evaluation concerned the dosimetric indicators: volume computed tomography dose index (CTDIvol) and dose–length product (DLP). The different paediatric CT protocols and practices were also evaluated. The results show a large variation in doses between different radiology departments. For head scans, the respective DRLs for children aged <1, 1–5, 5–10 and 10–15 years were 26, 38, 51 and 51 mGy, respectively, for CTDIvol and 384, 664, 873 and 978 mGy cm, respectively, for DLP. For the chest, the equivalent respective DRLs were 8, 10, 12 and 15 mGy for CTDIvol and 118, 330, 442 and 526 mGy cm for DLP. For the abdomen, the respective DRLs were 9, 13, 19 and 18 mGy for CTDIvol and 353, 485, 592 and 1073 mGy cm for DLP. This study shows that the optimisation of paediatric CT procedures should be a priority, especially within regional hospitals. The implementation of corrective actions will take place after the initial DRLs. These actions, including recommendations and guidelines to good practice, should be a joint effort of all stakeholders, including health authorities, the radiation protection regulator, professional societies and universities.

1 May 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ABABIR BOUAOUN
ABIR BOUAOUN
RAReem M. Althubaiti
Reem M. Althubaiti
RERoudinah Wail Edrees
Roudinah Wail Edrees
AMAfnan A Malaih
Afnan A Malaih
Background: Although Diagnostic Reference Levels (DRLs) based on anatomical regions are widely used in Computed Tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including volume CT dose index (CTDIvol) and the dose–length product (DLP) were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.

18 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ABABIR BOUAOUN
ABIR BOUAOUN
RAReem M. Althubaiti
Reem M. Althubaiti
RERoudinah Wail Edrees
Roudinah Wail Edrees
AMAfnan A Malaih
Afnan A Malaih
Background: Although diagnostic reference levels (DRLs) based on anatomical regions are widely used in computed tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including CT dose index (CTDIvol) and the dose–length product (DLP), were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.