Shadman Shahriar

Mr. Shadman Shahriar

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
Umar HasanUmar Hasan
Umar Hasan
SSShadman Shahriar
Shadman Shahriar
FHFaiyad Hossain
Faiyad Hossain
MHMd Alamgir Hossain
Md Alamgir Hossain
MMMuhammad Ali Martuza
Muhammad Ali Martuza
Sifat MomenSifat Momen
Sifat Momen
Background: Intelligent decision support systems for colonoscopy can fail when encountering out-of-distribution surgical instruments such as snares or biopsy forceps, producing false-positive polyp masks that may contribute to automation bias and reduce workflow reliability. This study aimed to develop and evaluate a parameter-efficient framework for open-set-aware polyp segmentation that can reject such anomalous inputs while preserving in-distribution segmentation performance. Methods: We propose PolypSAM-Open, which integrates a prototype-based Open-Set Learning (OSL) module with Low-Rank Adaptation (LoRA) in the MedSAM image encoder. The model was trained on Kvasir-SEG using an 85/15 split of authentic polyp images and synthetic high-frequency Gaussian noise to learn a rejection margin. Zero-shot out-of-distribution detection was evaluated on 590 unseen authentic surgical instruments from Kvasir-Instrument. Segmentation and detection performance were compared against a standard MedSAM-LoRA baseline. Results: Standard parameter-efficient fine-tuning yielded an OOD AUROC of 0.4263 on authentic surgical instruments. PolypSAM-Open improved zero-shot OOD AUROC to 0.9535 (p<0.001). Despite allocating 15% of training capacity to the synthetic-noise rejection margin, PolypSAM-Open maintained segmentation performance comparable to the standard fine-tuned baseline (Dice 0.9728 versus 0.9723). On ETIS-LaribPolypDB and CVC-ClinicDB, Dice scores were 0.9301 and 0.9386, respectively. The approach remained parameter-efficient, updating 4.48% of total parameters while adding negligible inference latency relative to the underlying MedSAM forward. Conclusions: Prototype-based open-set adaptation can substantially improve rejection of unseen surgical artifacts in AI-assisted colonoscopy while preserving high segmentation accuracy. These findings position PolypSAM-Open as a promising strategy for potentially safer decision-support segmentation in endoscopic workflows; prospective clinical validation remains necessary.