Engineered cementitious composites (ECCs) accommodate tensile deformation through distributed microcracking, but their strain capacity is commonly assessed on small specimens at 28 days. This is a critical narrative review to determine whether strain hardening is retained with age, production variability, and exposure, and whether retained capacity provides crack control and claimed durability. The synthesis combines micromechanical aspects, multi-age tensile observations, test method effects, transport, and healing of the cracked state. There are categories of evidence, indicating the extent of investigation, but methodological reliability is evaluated independently. Existing reviews give background for an integrated assessment of retention and are not evidence that ageing has been neglected. The approximate 54% reduction in ultimate strain after three years indicated by primary hybrid-ECC results and the approximate 84% reduction after one year indicated by secondary results from a different PVA-ECC system demonstrate that the overall performance of hybrid ECCs is superior to that of conventional eco-friendly concrete. The fly-ash mixtures tested with a different curing history have about 2–3% absolute strain at 90 days. These results are a function of the mixtures and cannot be combined into a global ageing factor. Further reaction can alter the toughness of a matrix and fibre–matrix bonding; geometry, gauge length, and production variability make comparisons difficult. Transport can be restricted in tight cracks as compared to wide-cracked mortars; however, other factors such as crack number, deformation, and exposure also affect transport. Proposals for age-specific characteristic strain capacity and capacity–demand screening criteria are made for research. None sets persistence in the absence of direct proof of ageing tensile properties. For practical use, the statistical factors, crack-width limits, and service-life assumptions need to be validated.
3 June 2026 in Journal of Building Material Science
The construction sector is a major contributor to global carbon emissions and the extinction of resources owing to the heavy use of natural aggregates and production of construction and demolition waste (CDW). The paper examines the viability of using recycled aggregates in the form of CDW as substitutes (0, 10, 30 and 50) of natural coarse aggregates in M25 structural concrete. Experimental testing comprised workability, density, water absorption and compressive strength after 7 and 28 days, which was backed by statistical analysis at 95% confidence level. The findings have shown that the workability reduces with high content of CDW because of augmented water absorption. Internal curing effect enhanced the 10% replacement with the highest compressive strength (31.52 MPa), which was up by 3.5% compared to control. The 30% replacement was found to give similar strength (29.82 MPa) with no statistically significant difference whereas the 50% replacement was found to allow significant reduction as a result of increasing porosity and reducing interfacial transition zones. The replacement level was positively correlated with water absorption, which means that pore connectivity was high. The sustainability analysis indicated possible CO2 cuts between 6–10% on 30% replacement. The results confirm that at least 30% CDW recycled mixes can be used safely in the structural concrete without affecting the performance, which is in line with the principles of the circular economy and sustainable construction practices.
Seismic isolation systems are widely adopted in bridge engineering to reduce earthquake-induced force transfer and improve structural resilience. Conventional lead rubber bearings (LRBs) provide effective energy dissipation and period elongation; however, their limited recentering capability may result in significant residual displacement after strong ground motions. This study investigates the seismic performance of a two-level shape memory alloy–lead rubber bearing (TL-LRB-SMA) hybrid isolation system for multi-span bridges considering structural flexibility, support compliance, and geometric irregularity. A nonlinear analytical model of the hybrid isolator was developed and validated under cyclic loading using benchmark hysteretic behavior from the literature. Subsequently, a multi-degree-of-freedom numerical model of an eleven-span benchmark bridge was established and verified through modal analysis, equivalent static analysis, and comparison with MSBridge software (MSBridge Beta 1.0.1). Nonlinear time-history analyses were performed using multiple excitation scenarios, including the 1940 El-Centro record, Kobe ground motion, oblique seismic incidence, and combined loading cases. Flexible foundation conditions were represented using equivalent translational soil springs. The results indicate that the TL-LRB-SMA system consistently improves self-centering performance and significantly reduces residual displacement relative to conventional LRBs. For the regular bridge with 48 ft piers, residual displacement decreased from 0.786 inches to 0.268 inches under El-Centro excitation, while under combined excitation it reduced from 0.264 inches to 0.087 inches. For irregular bridge configurations, substantial residual displacement reductions were also observed under both longitudinal and oblique loading. Although moderate increases in peak displacement occurred in some cases due to staged SMA activation, the overall recentering performance improved markedly. Overall, the proposed TL-LRB-SMA system demonstrates strong potential for enhancing seismic resilience and post-earthquake serviceability of bridge structures, particularly in flexible and irregular configurations.