Alex Krane

Mr. Alex Krane

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
DYDerick Yongabi
Derick Yongabi
AKAlex Krane
Alex Krane
Heloisa Espreafico Guelerman RamosHeloisa Espreafico Guelerman Ramos
Heloisa Espreafico Guelerman Ramos
SBSofia Xavier Bustia
Sofia Xavier Bustia
Jonas GruberJonas Gruber
Jonas Gruber
PWPatrick Wagner
Patrick Wagner
Rapid, low-cost ethanol quantification is vital for beverage quality control, biofuel production, and pharmaceutical applications, yet current approaches are costly, reagent- or label-dependent, or rely on spectroscopy with substantial sample preparation. We introduce a purely cell-based, label-free biosensor that exploits temperature-gradient-induced spontaneous detachment of Saccharomyces cerevisiae from a chip surface. The readout is the detachment half-time, td50, derived from time-resolved changes in interfacial thermal resistance, Rth, at the solid–liquid interface. Cells were pre-exposed to ethanol (0–70% v/v) and the detachment kinetics monitored using the heat transfer method (HTM). Under these conditions, cells display a pronounced non-monotonic td50 response with a peak around 20% v/v ethanol. Overall, the td50 rises from ~45 min (0% ethanol) to ≳10 h (20%) and then decreases, with no detachment at 60% and beyond. Critically, cell quality gates the detachment window. Fresh yeast responds up to ~50%, whereas aged yeast ceases to detach above ~8%, demonstrating a dual-function assay. Complementary measurements show that ethanol decreases surface tension monotonically, as expected, while optical/SEM imaging reveals aggregation above the detachment window. Requiring only a heater and a temperature probe, this platform offers a compact and low-cost strategy for ethanol sensing. Its applicability in a complex matrix is further demonstrated using whiskey diluted to selected alcohol concentrations, which produced responses consistent with the ethanol calibration trend. Potentially, it also offers a thermal assay for real-time monitoring of microbial cell quality across biotechnology and bioengineering applications. Considering ethanol as a proxy for drugs, the strategy may also support label-free drug screening on cells. At a fundamental level, the non-monotonic effect of ethanol, and especially the sharp maximum at 20%, remains unresolved and invites further studies.