Guang Luo

Dr. Guang Luo

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2023 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
GLGuang Luo
Guang Luo
YHY. K. Hor
Y. K. Hor
PLPei-Zhi Lu
Pei-Zhi Lu
ZWZhi-Min Wang
Zhi-Min Wang
RLRu-Hui Li
Ru-Hui Li
FAFeng-Peng An
Feng-Peng An

11 April 2025 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
GLGuang Luo
Guang Luo
XYXiao-Hao Yin
Xiao-Hao Yin
FAFengpeng An
Fengpeng An
ZWZhi-Min Wang
Zhi-Min Wang
YHY. K. Hor
Y. K. Hor
XXXiang Xiao
Xiang Xiao

12 February 2026 in arXiv
Verified
Preprint
Open access
PDF file
YLYuhang Liu
Yuhang Liu
FAFengpeng An
Fengpeng An
GLGuang Luo
Guang Luo
WWWei Wang
Wei Wang
WWWei Wei
Wei Wei
XYXiaohao Yin
Xiaohao Yin
We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse shape discrimination (PSD) performance ofSG101 were evaluated under AmBe neutron irradiation. When coupled with organic scintillators(EJ200 or EJ276),the SG101 EJ200 system achieves a figure of merit (FOM) of 3.81 for thermal neutron/gamma separation, while the SG101 EJ276 configuration resolves three distinct particle populations gamma rays, fast neutrons, and thermal neutrons with FOM values of 3.46 and2.21, respectively. Correlation analysis reveals that the number of fast thermal neutron coincidence events significantly exceeds the accidental background, and the count of gamma fast thermal neutron triple-coincidence events is also far higher than the expected accidental rate, confirming significant physical correlations for both event types within a 100 us time window. These results demonstrate that SG101 is a promising candidate for applications requiring high-efficiency thermal neutron detection and precise event tagging coupling with a scintillator with PSD approach

1 October 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
DLDiXiao Lu
DiXiao Lu
YLYuHang Liu
YuHang Liu
XZXueSong Zhang
XueSong Zhang
FAFengpeng An
Fengpeng An
GLGuang Luo
Guang Luo
WWWei Wang
Wei Wang
Surface-level reactor antineutrino experiments usually have substantial cosmic-ray-induced neutron backgrounds, particularly with shallow overburden. The Array of Lattice for Anti-neutrino Reactor Monitoring (ALARM) is a plastic scintillator-based experiment designed for reactor power monitoring. It will be deployed about 44 m from the core of a reactor at the Taishan Nuclear Power Plant. Placed at a depth of 9.6 meters below the surface, cosmic-ray-induced fast neutrons constitute a significant background, making an effective neutron shielding system essential for the experiment. For the shielding design of ALARM, we tested the shielding performance of three materials — water, HDPE, and 40% boron-doped HDPE (BHDPE) — against both fast and thermal neutrons. A thermal neutron detector composed of an EJ426 scintillator setup was first used to measure the shielding efficiency of these materials at various thicknesses using neutrons from an Am-Be source. A 30-cm thickness of BHDPE achieved a shielding efficiency exceeding 95% for both fast and thermal neutrons. Monte Carlo simulations of the EJ426 setup yielded results consistent with the experimental data. Simulation results for the shielding performance of the full ALARM shielding assembly are also presented.

17 December 2025 in arXiv
Verified
Preprint
Open access
PDF file
YLY. H. Liu
Y. H. Liu
XZX. S. Zhang
X. S. Zhang
DLD. X. Lu
D. X. Lu
WWWei Wang
Wei Wang
GLGuang Luo
Guang Luo
FAFengpeng An
Fengpeng An
Detecting fast and thermal neutrons plays a crucial role in neutrino experiments and reactor physics. In this study, we propose a plastic scintillator detector which demonstrates the ability to clearly distinguish fast neutrons, thermal neutrons, and gamma rays within mixed radiation fields, offering a practical approach for multi-radiation detection. Two plastic scintillator assemblies: EJ200+EJ426 and EJ276+EJ426 were setup, and the system energy response was calibrated using three gamma sources(137Cs, 22Na and 60Co). An Am-Be neutron source was employed, and pulse shape discrimination(PSD) was used to separate fast neutrons, thermal neutrons and gamma rays. Using a three-sigma discrimination criterion, the EJ200+EJ426 configuration was found to reliably distinguish thermal neutrons from gamma rays, while the EJ276+EJ426 configuration can effectively discriminate fast neutrons, thermal neutrons and gamma rays at gamma-equivalent energies above 1 MeV.

6 April 2026 in The European Physical Journal C
Verified
Journal Article
Open access
LXLingfeng Xie
Lingfeng Xie
JLJiajun Liu
Jiajun Liu
YZYifei Zhao
Yifei Zhao
CCChang Cai
Chang Cai
GCGuocai Chen
Guocai Chen
XZXiaopeng Zhou
Xiaopeng Zhou
The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dual-phase xenon time projection chamber (TPC). To validate the detector concept and ensure technical reliability for the full-scale experiment, a dedicated prototype was designed, constructed, and operated. This work presents an overview of the design, construction, and operational performance of the prototype, with emphasis on its major subsystems, including the TPC, cryogenics and xenon purification systems, slow control, and data acquisition. During operation, the detector demonstrated the capability to achieve a sub-keV energy threshold required for the RELICS physics program, as reflected by a measured single electron gain of (34.30 ± 0.01 (stat.)) PE/e $$^-$$ - and the successful detection of $$\mathrm {0.27~keV}$$ 0.27 keV L-shell decay events from $$\mathrm {^{37}Ar}$$ 37 Ar . In addition, essential data analysis techniques and simulation frameworks were developed and validated, establishing the technical foundation for future RELICS operations. The successful construction and operation of this prototype confirm the feasibility of the core technologies and provide the experimental basis for the full-scale RELICS detector.