Yan Xu

Dr. Yan Xu

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CWChuangwei Wei
Chuangwei Wei
YXYan Xu
Yan Xu
RZRunzhi Zhang
Runzhi Zhang
WZWenjing Zhao
Wenjing Zhao
NZNan Zhang
Nan Zhang
Zhaoying WenZhaoying Wen
Zhaoying Wen
Background: This study aimed to evaluate the image quality of non-contrast-enhanced whole-heart coronary MR angiography (CMRA) using three different sequences: coronal-plane balanced turbo field echo (BTFE) at 3T, axial-plane modified Dixon (mDixon) at 3T, and axial-plane mDixon at 5T. Methods: Healthy young volunteers were prospectively enrolled from January 2025 to April 2025. Each participant underwent three CMRA scans—3T BTFE, 3T mDixon, and 5T mDixon—using customized MR protocols, all performed within 48 h. Subjective image quality was assessed based on the society of cardiovascular computed tomography 18-segment model using a four-point scale (1 = non-assessable to 4 = excellent). The assessability rate was defined as the percentage of segments receiving a score ≥ 2. Objective evaluation of the main coronary arteries included measurements of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel edge sharpness (VES), and visible vessel length. The Friedman test and one-way repeated measures analysis of variance (ANOVA) were performed to compare parameters obtained from 3T BTFE, 3T mDixon, and 5T mDixon. Results: A total of 20 participants (10 men; mean age, 24 ± 2 years) were included. Both 5T mDixon and 3T BTFE showed more favorable subjective image quality than 3T mDixon, particularly in distal and branch-level coronary segments. All three sequences achieved high vessel assessability. Quantitatively, 5T mDixon provided the highest SNR and CNR, while 3T BTFE showed the highest VES. Visible vessel lengths in LAD and RCA were longer with 5T mDixon and 3T BTFE versus 3T mDixon. However, 5T mDixon required the longest acquisition time (12.55 ± 2.80 min), consistent with its higher spatial resolution. Conclusions: In conclusion, in healthy volunteers, both 5T mDixon and 3T BTFE outperformed 3T mDixon in non-contrast CMRA, particularly in distal and branch-level coronary segments. While 5T mDixon provided the highest SNR and CNR, 3T BTFE achieved the greatest VES. These findings support the technical feasibility of both approaches, but further studies in patients are needed to confirm their clinical applicability

1 June 2026 in Thoracic Radiology
Verified
Journal Article
Open access
YXYan Xu
Yan Xu
HXHongyan Xie
Hongyan Xie
RZRunzhi Zhang
Runzhi Zhang
CWChuangwei Wei
Chuangwei Wei
DLDongting Liu
Dongting Liu
DHDan Han
Dan Han

7 August 2026 in Journal of Thoracic Imaging
Verified
Journal Article
Open access
YXYan Xu
Yan Xu
HXHui Xu
Hui Xu
NZNan Zhang
Nan Zhang
YLYongxin Li
Yongxin Li
EZErhui Zhang
Erhui Zhang
Zhaoying WenZhaoying Wen
Zhaoying Wen
Purpose: To investigate the clinical outcomes of acute Stanford type B intramural hematoma (TBIMH) without ulcer-like lesions following medical management and to identify predictors of disease progression. Materials and Methods: A retrospective analysis was performed on patients with acute TBIMH without ulcer-like lesions who received medical management. Patients were categorized into progression and nonprogression groups based on 1-year follow-up computed tomography angiography (CTA). Disease progression was defined as aortic rupture, aortic dissection, aortic enlargement (≥5 mm), or hematoma thickening (≥3 mm), while nonprogression was defined as complete/partial resolution or retention of the hematoma. A multivariate analysis identified the predictors of disease progression, and Kaplan-Meier curves were used to compare survival outcomes. Results: A total of 110 patients (mean age 55.9±10.5 y, 25 females) were included, with 21 patients (19.1%) showing disease progression. Multivariate analysis revealed that the maximum aortic diameter (MAD) (OR=7.6, P =0.003) and maximum CT value of the hematoma (CTmax) (OR=1.04, P =0.025) were independently associated with disease progression. The optimal cutoff values for MAD and CTmax were 40.0 mm (AUC: 0.69, sensitivity: 38.1%, specificity: 92.1%) and 71.9 HU (AUC: 0.68, sensitivity: 76.2%, specificity: 66.3%), respectively. When MAD and CTmax were combined, the AUC increased to 0.75 (sensitivity: 81.0%, specificity: 66.3%). Conclusion: A model based on MAD and CTmax effectively stratifies progression risk in TBIMH without ulcer-like lesions, facilitating early intervention in high-risk patients.

Verified
Journal Article
Open access
PDF file
YXYan Xu
Yan Xu
CWChuangwei Wei
Chuangwei Wei
RZRunzhi Zhang
Runzhi Zhang
JDJiahuan Dai
Jiahuan Dai
HXHui Xu
Hui Xu
Zhaoying WenZhaoying Wen
Zhaoying Wen
Background/Objectives: This prospective study evaluated the feasibility of a non-contrast 5T one-stop MRA protocol for simultaneous assessment of the thoracic aorta and coronary arteries and examined the effect of heart rate (HR) on image quality. Methods: Thirty-four healthy volunteers underwent 5T MRA and were stratified by median HR into Low-HR (≤70 bpm, n = 17) and High-HR (>70 bpm, n = 17) groups. Subjective image quality was assessed using a 4-point scale, and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel edge sharpness (VES) were measured in predefined aortic and proximal coronary segments. Results: The protocol was successfully completed in all participants, and all evaluated segments were evaluable. Interobserver and intraobserver agreement was excellent (kappa ≥ 0.90; ICC ≥ 0.85). Subjective aortic scores did not differ between HR groups, whereas several coronary segments had lower scores in the High-HR group. SNR, CNR, and VES were higher in the Low-HR group across all objectively assessed segments. Conclusions: These findings support the technical feasibility of integrated 5T non-contrast MRA in healthy volunteers and suggest that the subjective effect of higher HR is more evident in the coronary arteries than in the thoracic aorta, warranting further validation in patients with cardiovascular disease.