Feng Xu

Dr. Feng Xu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2025 in Buildings
Verified
Journal Article
Open access
PDF file
JYJiaTao Yin
JiaTao Yin
XWXinyue Wang
Xinyue Wang
SWShichao WANG
Shichao WANG
Gang ZhangGang Zhang
Gang Zhang
TGTong Guo
Tong Guo
FXFeng Xu
Feng Xu
Advancing rapidly in modern bridge engineering technology, through concrete-filled steel tubular (CFST) arch bridges have achieved widespread application in transportation infrastructure development. Nevertheless, vehicle fires occurring in complicated operational settings may rapidly escalate into major disasters. Fires in oil tankers are particularly dangerous for the safety of bridges. This study examines the fire resistance of through concrete-filled steel tubular (CFST) arch bridges exposed to tanker truck fires. The study formulates a detailed model utilizing Fire Dynamics Simulator (FDS) to simulate fire scenarios, elucidating the spatial temperature distribution characteristics within arch bridge structures. A three-dimensional finite element model established in ABAQUS (Abaqus 2024, Dassault Systèmes Simulia Corp, Providence, RI, USA) is employed to simulate structural responses by analyzing the mechanical behavior of key components under different fire conditions. Practical fire resistance design recommendations for extreme tanker truck fire scenarios are ultimately proposed. Numerical results demonstrate that structural components near the fire source (such as transverse bracings, hangers, and fire-exposed arch surfaces) experience significantly higher temperatures than other regions. Notable temperature gradients developing along hangers and arch ribs in fire-affected zones are observed, while substantial cross-sectional temperature gradients occurring in these components under tanker truck fires reveal their damage evolution mechanisms. The fire exposure scenario at the quarter-point of the midspan is identified as the most critical fire exposure scenario for through CFST arch bridges under tanker truck fires. Under this extreme scenario, the deflection on the fire-exposed side of the global structure exhibits a significant three-stage distribution characteristic: an initial ascending phase around 0–800 s, followed by a sharp descending phase during 800–1100 s, and then a stabilization trend. A fire resistance limit criterion based on component failure (tf3 = 853.43 s) is established, and a global fire resistance limit assessment methodology for through CFST arch bridges under extreme tanker truck scenarios is proposed.

19 August 2026 in Buildings
Verified
Journal Article
Open access
PDF file
FXFeng Xu
Feng Xu
ZLZelei Lu
Zelei Lu
CLChang Liu
Chang Liu
EZEnhai Zhou
Enhai Zhou
ZCZhaohui Chen
Zhaohui Chen
SWShichao WANG
Shichao WANG
This paper presents a methodology to evaluate the entire process of thermal evolution and fracture failure within stay cables subjected to sheath fires. Computer software FDS 2021 and ABAQUS 2021 are applied to build a sequentially thermos–mechanics coupled method integrating thermal, structural, and fracture dynamic analyses in stay cables under sheath fire exposure conditions. Herein, three representative fire scenarios including full-circumferential, top-side, and bottom-side ignition are reconstructed. Further, 127 individual wires, accounting for interstitial cavity radiation and contact heat transfer, are utilized to perform analysis on sectional temperature in stay cables. The results indicate that the ignition mode dictates the cross-sectional temperature gradient, with localized ignitions inducing highly asymmetric thermal fields and pronounced internal bending moments. Elevated temperatures trigger a progressive load redistribution from the degraded fire-facing wires to cooler internal layers. Ultimately, abrupt global fracture occurs when the residual ultimate load-carrying capacity intersects with the actual applied tension, resulting in a fracture morphology that closely corresponds to the spatial thermal distribution. Furthermore, the structural capacity degradation exhibits three distinct time-dependent stages: a slow degradation stage, a sharp decline stage, and a recovery stage. Among the analyzed scenarios, full-circumferential ignition induces the most drastic overall capacity reduction, while bottom-side ignition poses a markedly greater rupture risk than top-side ignition.