In previous numerical and experimental studies of the intramedullary nail-implanted human femur several simplifications to model the boundary and loading conditions during pre-clinical testing have been proposed. The distal end of the femur was fixed in the majority of studies dealing with the biomechanics of the lower extremity, be it numerical or experimental, which resulted in obviously non-physiological deflections. Per contra, Speirs et al. (2007) proclaimed physiological deflections as a result of constraining the femur in a novel statically determinate fashion in combination with using a complex set of muscle forces. In tandem with this, we have shown that not only the deflections but also the stress and strain predictions turn out to be much lower in magnitude, as a result of using the latter approach. To illustrate the dramatic change in results, we compared these results with those of two other models employing commonly used boundary and loading conditions in retrograde stabilization of a distal diaphyseal fracture. The model used herewith resulted in more realistic femoral cortical strains, lower stresses on both the nail and the screws, as well as such deflections in the overall structure.
Finite element analysis is a powerful tool that is often used to study the biomechanical response of the spine. The primary objective of this study was to illustrate the mechanical behavior of a previously proposed parametric CAD spine model in comparison with a segmented FSU model and the literature. In this study, two finite element models of the L4-L5 spinal level were developed from the same patient's CT scan data. The first was developed using well-known segmentation methods, whereas the second was developed from the new by using a novel parametric CAD model. Both models were subjected to the same loading and boundary conditions to perform flexion, extension, lateral bending and axial rotation motions. The segmented finite element model was observed to be in good agreement with the literature. The parametric finite element model results were also observed to be in good agreement with the segmented finite element model and with the literature except under extension.
Intramedullary (IM) distractor nails have become a viable alternative in bone-distraction operations. Upon stabilization of the fractured/dissected limb via the nail, the resulting construct accommodates the load bearing function of the otherwise healthy limb. In establishing design performance targets for these devices, in vitro test conditions are widely accepted leaving the in vivo conditions aside. However, in vivo device failures due to distraction forces necessitate novel modeling considerations. It is especially important to simulate the loads in limb distraction, as this brings the bone-implant construct to a totally different regime than the hip-joint contact force (Point-Force Model, PFM). In this work we used a simplified approach to incorporate ligament stretching due to limb distraction via self-equilibrating spring elements in a finite-element setting (spring-force model, SFM). We compared the effect of loading type on load transmission paths through the locking pins, for these two distinct loading modes, namely, SFM and PFM. The two modes illustrate entirely different load transfer regimes around the bone/nail interface region. In order to avoid high contact stresses between the nail and the bone segments, it is advisable to keep the osteotomy away from the mid-range between the pin connections. It was also seen for both loading modes that including an additional pin at a load transfer location does not significantly alter the load carried by a single pin (the additional pin rather acts as a geometric stabilizer).