Long‐term liquids diffusion tests were performed on glass fibre reinforced polymer (GFRP) used in high voltage composite insulator. The plate‐shaped GFRP specimens were immersed in three types of liquids, which high voltage composite insulator would encounter in practice, including deionised water, NaCl solution and nitric acid solution for a period of 4000 h. Chemical reaction and physical dissolution complicated the diffusion processes, which could be divided into three types based on the features of diffusion curves. Fourier transform infrared spectroscopy, scanning electron microscopy and optical interferometry were employed to investigate the chemical property, two‐dimensional (2D) and 3D surface morphologies of GFRP. The results revealed that the surface layer of GFRP was destroyed to some extent depending on the type and concentration of the liquid, the maximum of profile height deviation of GFRP surface was proposed to evaluate the extent of the corrosion of GFRP, the greater the profile height deviation, the more serious the corrosion of GFRP. The present work is helpful for a better understanding of the diffusion behaviour of liquids into GFRP used in high voltage composite insulator as well as in other industry applications.
High‐temperature vulcanised (HTV) silicone rubber composite insulator has been widely used in extra‐high and ultra‐high transmission lines due to its excellent electrical and mechanical performance. In practice use, liquids may encounter the composite insulator intermittently and can lead to the degradation and deterioration of silicone rubber. In the present research, the effects of liquids immersion and subsequent drying on the surface properties of HTV silicone rubber were investigated by means of the contact angle measurement and surface physical morphology measurement which was further analysed in terms of the discrete wavelet transform method, multiresolution signal decomposition algorithm, and three‐dimensional fractal dimension calculation. Based on the experimental results, the mechanism of the loss and recovery of the hydrophobicity of HTV silicone rubber surface during the liquids immersion and subsequent drying processes were further explained by taking into consideration the embedded water molecules (and/or hydrated ions) on the HTV silicone rubber surface and the synergy of the increase in roughness/fractal dimension and low molecular weight siloxanes diffusion. This study is helpful for better understanding of the change of surface properties of HTV silicone rubber caused by environmental and electrical stresses.
28 March 2017 in IEEE Transactions on Power Delivery
Transient enclosure voltage (TEV) induces a relative potential difference between grounding conductors and then couples to secondary cables and may cause malfunction and even damage to secondary equipment. This study investigates the coupling mechanism of TEV to secondary cables from an experimental point of view and presents a cable model suitable for calculation. Experiments are carried out on test platforms established in a laboratory. The experimental results indicate that the magnitudes of port voltages are roughly 1.5 0 / 00 of TEV magnitudes, and the waveform of the start port voltage has the same profile but in antiphase with that of the end port voltage. Moreover, only common-mode voltage with no differential-mode voltage exists for the twin core cable. Based on these results, an equivalent circuit for a secondary cable is proposed. This circuit can generate similar waveforms as those measured in the experiment. The experimental and theoretical results presented in this paper should prove helpful for evaluating the interference severity of secondary cables resulting from TEV for the electromagnetic protection of secondary ports.
Transient enclosure voltage (TEV), which is a phenomenon induced by the inner dielectric breakdown of SF6 during disconnector operations in a gas-insulated switchgear (GIS), may cause issues relating to shock hazard and electromagnetic interference to secondary equipment. This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage (UHV) substations. In this paper, the statistical characteristics of TEV at UHV level are collected from field experiments, and are analyzed and compared to those from a repeated strike process. The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first. Then, statistical characteristics, such as the pulse number, duration of pulses, frequency components, magnitude and single pulse duration, are extracted. The transmission line theory is introduced to analyze the TEV and is validated by the experimental results. Finally, the relationship between the TEV and the repeated strike process is analyzed. This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage. The results contribute to the definition of the standard testing waveform of the TEV, and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.
With the deepening of power market reform and the large-scale integration of bidirectional systems such as energy storage and electric vehicles, achieving sustainable carbon management has become increasingly urgent. Traditional carbon emission accounting methods face challenges, including insufficient dynamics and unclear responsibility boundaries. To address these issues, this paper proposes a sustainability-oriented accounting method for indirect carbon emissions from electricity in the context of bidirectional system integration in the power market environment. First, the dynamic carbon emission characteristics of bidirectional systems such as energy storage and vehicle-to-grid (V2G) systems are analyzed, and a carbon emission accounting model is constructed to address the fairness issue of emission responsibility allocation during charging and discharging. Second, on the basis of the theory of carbon emission flows and incorporating electricity trading contract data, an accounting method for indirect carbon emissions from electricity in green electricity trading, coal-fired electricity trading, and hybrid scenarios under bidirectional system integration is developed. Finally, the case study demonstrates that the proposed method accurately captures the temporal variation of carbon emission factors, ensures conservation of total emissions, and fairly redistributes carbon responsibility among users under different market scenarios, while revealing how bidirectional systems and green electricity trading reshape nodal carbon intensities and spatial emission distributions without causing double counting.
With the increasing penetration of electric vehicles (EVs), multi-virtual power plant (multi-VPP) systems face growing challenges in coordinating heterogeneous flexible resources, managing stochastic EV charging and discharging behaviors, and maintaining distribution network security. This paper develops an integrated collaborative scheduling strategy for multi-VPPs with EV cluster participation. In the proposed framework, EV clusters, energy storage systems, and distributed generation units are coordinated under distribution-network operational constraints. The regulation capability of EV clusters is characterized by considering state of charge (SOC) dynamics, charging/discharging power limits, arrival and departure times, vehicle availability, and user travel requirements and is further embedded into the scheduling decision space of each VPP. To coordinate operational economy and nodal voltage security, a voltage-security-aware optimization objective is formulated and transformed into a Markov game. A multi-agent deep reinforcement learning (MADRL) method is then adopted to learn coordinated scheduling policies among multiple VPP agents. Case studies show that the proposed method achieves stable convergence after approximately 3500 training episodes, with a normalized reward exceeding 0.92, and outperforms TD3, DDPG, and PPO in terms of convergence speed and training stability. The scheduling results further indicate that the proposed strategy effectively coordinates EV clusters and energy storage systems, maintains nodal voltages within safe limits, and improves the operational performance of multi-VPP systems. These results demonstrate the applicability of the proposed framework for secure and economic collaborative scheduling in distribution networks.