Application of the entropy information for the optimization of an additional measurements location in thermal systems: For the optimal location of an additional surplus measurements in the design of redundant measurements system, from data reconciliation point of view, of thermal processes, an information entropy has been applied. The relative entropy - Kullback-Leibler divergence, has been used. As a criterion of the optimal location of an additional surplus measurements in a system of measurements data, the minimum of the entropy information of reconciled measurements data has been assumed. Hence, the objective function in the described optimization task is maximum of the relative entropy - Kullback-Leibler divergence concerning sets of raw and reconciled measurements data. Simulation calculation with application of data reconciliation algorithm and Monte Carlo method concerning the influence of installation of the additional surplus measurements on decrease of entropy information of measurements after data validation have been carried out. The example calculations concerned the cross high-pressure heat regeneration system with cascade flow of condensate installed in 153 MW power unit equipped with cooler of steam are presented. Calculations for all variants of configurations of an additional surplus measurements in the analyzed thermal system have been done. Usefulness of the proposed Kullback-Leibler divergence as a objective function has been demonstrated.
This study explores the selection of a heat recovery system for cogeneration units based on gas engines supplying the district heating system in Opole in order to enhance the efficiency and sustainability of the system. The proposed modifications focus on utilizing low-temperature (LT) waste heat from engine cooling circuits and improving exhaust heat recovery. The research examines retrofitting three cogeneration engines (total thermal capacity of 7.6 MW) by integrating water-to-water heat pumps to upgrade low-temperature waste heat (55–45 °C up to 700 kW), enhancing heat supply to the district heating network. Additionally, a second stage of economizers is evaluated to maximize condensation-based exhaust heat recovery from the existing 95–135 °C system. These system modifications increase the overall thermal capacity up to 9–9.1 MW. To maintain heat supply during cogeneration unit shutdowns (due to failures or electricity price fluctuations), an auxiliary air-to-water cascade heat pump provides an additional 0.8–1 MW. With increasing electricity price volatility, these system modifications provide crucial operational flexibility. Computational simulations confirm that the hybrid configuration successfully upgrades waste heat while strictly maintaining the existing engine return water safety limit. The evaluation demonstrates high economic profitability alongside stable emission reductions. This research presents a case study in optimizing heat recovery in cogeneration-based district heating networks, demonstrating practical and scalable applications for sustainable energy systems.