ANDRÉS NICOLÁS VEGA MORAGA

Mr. ANDRÉS NICOLÁS VEGA MORAGA

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2025 in Experimental Physiology
Verified
Journal Article
Open access
DRDaniel Ramos‐López
Daniel Ramos‐López
RCRaul Paul Caulier Cisterna
Raul Paul Caulier Cisterna
BDBenjamín Díaz‐Ortiz
Benjamín Díaz‐Ortiz
CBCristóbal Baumann‐Biancani
Cristóbal Baumann‐Biancani
KHKamilo Hunger‐Abbott
Kamilo Hunger‐Abbott
Felipe Contreras–BriceñoFelipe Contreras–Briceño
Felipe Contreras–Briceño
Biological sex influences exercise performance, largely owing to anatomical and physiological differences in brain areas involved in cognitive motor control and in respiratory and locomotor muscles related to workload. We used near‐infrared spectroscopy data to examine sex differences in haemodynamic responses and oxygenation patterns in the prefrontal cortex (PFC), m. intercostales and m. vastus lateralis during incremental exercise in 74 endurance‐trained individuals. Changes (Δ) in oxyhaemoglobin (O 2 ‐Hb), deoxyhaemoglobin (H‐Hb) and tissue saturation index (TSI) were analysed using a two‐way ANOVA with the factors ‘sex’ and ‘intensity’. Effect sizes (ES) were also reported by partial eta squared (η p 2 ). Interactions were observed for ΔO 2 ‐Hb at the PFC [ p < 0.001, η p 2 = 0.42 (large ES)] and m. intercostales [ p < 0.001, η p 2 = 0.38 (large ES)], but not at m. vastus lateralis ( p = 0.160). For ΔH‐Hb, interactions were observed at m. vastus lateralis [ p < 0.001, η p 2 = 0.35 (large ES)] and the PFC [ p = 0.048, η p 2 = 0.18 (large ES)]. The ΔTSI also showed an interaction at m. vastus lateralis [ p < 0.001, η p 2 = 0.44 (large ES)] and a trend in the m. intercostales ( p = 0.057). Male subjects demonstrated greater oxygen delivery to the brain and increased peripheral deoxygenation, whereas females exhibited greater oxygen extraction in respiratory muscles, despite smaller body surface area. Higher tissue oxygen extraction reflects the capacity to meet local metabolic demands during exercise, enabling the identification of distinct oxygenation patterns between sexes. These findings suggest that sex‐specific mechanisms contribute to different patterns of physiological response to exercise. We support the hypothesis that peripheral factors might be more limiting in males, whereas in females central limitations (such as potential reduced oxygen delivery to the PFC owing to possible cerebral vasoconstriction triggered by metabolic reflexes) might play a more prominent role.

15 June 2026 in Medical Sciences
Verified
Journal Article
Open access
PDF file
RCRaul Paul Caulier Cisterna
Raul Paul Caulier Cisterna
AMANDRÉS NICOLÁS VEGA MORAGA
ANDRÉS NICOLÁS VEGA MORAGA
DRDaniel Ramos-López
Daniel Ramos-López
Felipe Contreras–BriceñoFelipe Contreras–Briceño
Felipe Contreras–Briceño
Background: Near-infrared spectroscopy (NIRS)-based wearable devices offer non-invasive, continuous monitoring of muscle oxygenation, providing direct microvascular and metabolic information that complements indirect indices of intensity such as heart rate and accelerometry. Their clinical applicability in chronic non-communicable diseases (NCDs) remains under active development. Methods: A structured narrative review was conducted in PubMed, Scopus, Web of Science, and IEEE Xplore (January 2010–January 2026) using pre-specified search strings combining NIRS, muscle oxygenation, SmO2, StO2, wearable, exercise intensity, ventilatory/lactate threshold, and individual chronic disease terms. Eligible studies addressed technical validation of wearable NIRS, NIRS-derived exercise intensity estimation, clinical applications in NCDs, or rehabilitation implementation. Evidence was synthesized thematically; quality of validation studies was appraised against AMSTAR-2-informed, COSMIN-informed, or Cochrane RoB-2 criteria. Results: Wearable continuous-wave NIRS shows acceptable concurrent validity with frequency-domain laboratory systems (r = 0.79; range 0.69–0.88; ±8% SmO2 agreement in 95% of measurements) and good test–retest reliability for moderate-to-severe domains (ICC 0.72–0.91). NIRS-derived breakpoints align more reliably with the second ventilatory/lactate threshold (ICC = 0.80) than with the first (ICC = 0.53), constraining its use for prescribing lower-intensity domains. In chronic obstructive pulmonary disease, peripheral arterial disease, chronic respiratory failure and selected cardiovascular conditions, wearable NIRS detects disease-specific patterns of muscle deoxygenation and post-exercise reoxygenation that track responses to rehabilitation. Conclusions: Current evidence supports wearable NIRS as a complementary, intensity-aware monitoring tool—particularly for delineating the heavy/severe-intensity boundary and detecting peripheral metabolic limitations—rather than as a stand-alone replacement for ventilatory or lactate thresholds. Because much of the evidence derives from small, single-sex or athlete-only cohorts, these findings should be regarded as a promising basis requiring further validation in broader NCD populations. Implementation in NCDs requires standardized placement and calibration protocols, sex- and body composition-stratified reference values, motion-artifact mitigation, and adequately powered longitudinal trials in clinical populations.