Real-time environment monitoring and analysis is an important research area of Internet of Things (IoT). Understanding the behavior of the complex ecosystem requires analysis of detailed observations of an environment over a range of different conditions. One such example in urban areas includes the study of tree canopy cover over the microclimate environment using heterogeneous sensor data. There are several challenges that need to be addressed, such as obtaining reliable and detailed observations over monitoring area, detecting unusual events from data, and visualizing events in real-time in a way that is easily understandable by the end users (e.g., city councils). In this regard, we propose an integrated geovisualization framework, built for real-time wireless sensor network data on the synergy of computational intelligence and visual methods, to analyze complex patterns of urban microclimate. A Bayesian maximum entropy-based method and a hyperellipsoidal model-based algorithm have been build in our integrated framework to address above challenges. The proposed integrated framework was verified using the dataset from an indoor and two outdoor network of IoT devices deployed at two strategically selected locations in Melbourne, Australia. The data from these deployments are used for evaluation and demonstration of these components' functionality along with the designed interactive visualization components.
Good water quality is essential for the health of our aquatic ecosystems. Continuous water quality monitoring is an important tool for catchment management authorities, providing real-time data for environmental protection and tracking pollution sources; however, continuous water quality monitoring at high temporal and spatial resolution remains prohibitively expensive. An affordable wireless aquatic monitoring system will enable cost-effective water quality data collection, assisting catchment managers to maintain the health of aquatic ecosystems. In this paper, a low-cost wireless water physiochemistry sensing system is presented. The results indicate that with appropriate calibration, a reliable monitoring system can be established. This will allow catchment managers to continuously monitoring the quality of the water at higher spatial resolution than has previously been feasible, and to maintain this surveillance over an extended period of time. In addition, it helps to understand the behavior of aquatic animals relative to water pollution using data analysis.
Internet of Things (IoT) enables the seamless integration of sensors, actuators, and communication devices for real-time applications. IoT systems require good quality sensor data in order to make real-time decisions. However, values are often missing from the sensor data collected owing to faulty sensors, a loss of data during communication, interference, and measurement errors. Considering the spatiotemporal nature of IoT data and the uncertainty of the data collected by sensors, we propose a new framework with which to impute missing values utilizing Bayesian maximum entropy (BME) as a convenient means to estimate the missing data from IoT applications. Missing sensor measurements adversely affect the quality of data, and consequently the performance and outcomes of IoT systems. Our proposed framework incorporates BME in order to impute missing values in diverse IoT scenarios by making use of the combination of low- and high-precision sensors. Our approach can incorporate the measurement errors of low-precision sensors as interval quantities along with the high-precision sensor measurements, making it highly suitable for real-time IoT systems. Our framework is robust to variations in data, requires less execution time, and requires only a single input parameter, thus outperforming existing IoT data imputation methods. The experimental results obtained for three IoT data sets demonstrate the superiority of the BME framework as regards accuracy, running time, and robustness. The framework can additionally be extended to distributed IoT nodes for the online imputation of missing values.
Analyzing crowd events in a video is key to understanding the behavioral characteristics of people (humans). Detecting crowd events in videos is challenging because of articulated human movements and occlusions. The aim of this paper is to detect the events in a probabilistic framework for automatically interpreting the visual crowd behavior. In this paper, crowd event detection and classification in optical flow manifolds (OFMs) are addressed. A new algorithm to detect walking and running events has been proposed, which uses optical flow vector lengths in OFMs. Furthermore, a new algorithm to detect merging and splitting events has been proposed, which uses Riemannian connections in the optical flow bundle (OFB). The longest vector from the OFB provides a key feature for distinguishing walking and running events. Using a Riemannian connection, the optical flow vectors are parallel transported to localize the crowd groups. The geodesic lengths among the groups provide a criterion for merging and splitting events. Dispersion and evacuation events are jointly modeled from the walking/running and merging/splitting events. Our results show that the proposed approach delivers a comparable model to detect crowd events. Using the performance evaluation of tracking and surveillance 2009 dataset, the proposed method is shown to produce the best results in merging, splitting, and dispersion events, and comparable results in walking, running, and evacuation events when compared with other methods.
17 June 2015 in IEEE Journal of Biomedical and Health Informatics
Epilepsy is one of the most common neurological disorders and patients suffer from unprovoked seizures. In contrast, psychogenic nonepileptic seizures (PNES) are another class of seizures that are involuntary events not caused by abnormal electrical discharges but are a manifestation of psychological distress. The similarity of these two types of seizures poses diagnostic challenges that often leads in delayed diagnosis of PNES. Further, the diagnosis of PNES involves high-cost hospital admission and monitoring using video-electroencephalogram machines. A wearable device that can monitor the patient in natural setting is a desired solution for diagnosis of convulsive PNES. A wearable device with an accelerometer sensor is proposed as a new solution in the detection and diagnosis of PNES. The seizure detection algorithm and PNES classification algorithm are developed. The developed algorithms are tested on data collected from convulsive epileptic patients. A very high seizure detection rate is achieved with 100% sensitivity and few false alarms. A leave-one-out error of 6.67% is achieved in PNES classification, demonstrating the usefulness of wearable device in the diagnosis of PNES.
Background: Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive treatment.Method: A novel approach for monitoring stroke during the first few hours after the onset of stroke using a wireless accelerometer based motor activity monitoring system is developed. It monitors the motor activity by measuring the acceleration of the arms in three axes. In the presented proof of concept study, the measured acceleration data is transferred wirelessly using iMote2 platform to the base station that is equipped with an online algorithm capable of calculating an index equivalent to the National Institute of Health Stroke Score (NIHSS) motor index. The system is developed by collecting data from 15 patients.Results: We have successfully demonstrated an end-to-end stroke monitoring system reporting an accuracy of calculating stroke index of more than 80%, highest Cohen’s overall agreement of 0.91 (with excellentκcoefficient of 0.76).Conclusion: A wireless accelerometer based ‘hot stroke’ monitoring system is developed to monitor the motor recovery in acute-stroke patients. It has been shown to monitor stroke patients continuously, which has not been possible so far with high reliability.