The aim of the study was to evaluate the release of the lingual frenulum through frenectomy in newborns zero to 90 days of age who breastfed and had diagnosis of ankyloglossia with an indication for surgery, comparing two methods: electrocautery and a high-power diode laser. Fifty-seven patients were randomly allocated to two groups (23 submitted to electrocautery and 34 submitted to a high power diode laser). Tongue movements were evaluated based on a clinical assessment and using the Bristol Tongue Assessment Tool (BTAT) before and 15 days after the surgical procedures. The visual analog scale was administered to the mothers on the same occasions for the measurement of pain during breastfeeding. Both groups had an increased BTAT score (favorable outcome) at the post-surgical evaluation, but the anterior third of the tongue was not always free to enable the movements necessary for lingual functions. It is fundamental for surgeons to have skill and in-depth knowledge of the equipment used to avoid accidents and complications in the region of important structures. Both techniques employed in this study were safe and effective, causing little bleeding and few postoperative complications. The group submitted to a high-power diode laser exhibited less post-surgical bleeding compared to the group submitted to electrocautery and no inflammation at the edges of the surgical cut.
Introduction: Orofacial pain and tensional cephalea were symptoms commonly reported in COVID-19 patients, even after recovery, and were considered chronic pain in these cases. The aim of this research is to evaluate the effect of the application of photobiomodulation with red and infrared lasers applied locally and systemically. Methods and analysis: For this purpose, individuals who have been diagnosed with COVID-19 and have had a tension headache and/or orofacial pain for more than 3 months will be selected by convenience. The participants will be divided into two different groups: G1-photobiomodulation with red and infrared laser with local application on the pain points (808 nm and 660 nm, 100 mW, 6 J per point) and G2-photobiomodulation with red laser with transcutaneous application on the radial artery (660 nm, 100 mW, 30 minutes). All participants will be treated for a period of 4 weeks, with 8 application sessions. The effects will be measured by means of blood lactate level, Brief Pain Inventory, Visual Analog Scale (VAS), and Cephalea Impact Test. The data will be collected weekly before and after the treatment, and the following tests will be applied: Analysis of variance (ANOVA), Tukey paired t test, Kruskal–Wallis, or Wilcoxon, according to data distribution. α = 0.05 will be considered as the level of statistical significance. Ethics and dissemination: This study was approved by the Research Projects Committee of the Nove de Julho University (approval number 4.673.963). Results will be disseminated through peer-reviewed journals and events for the scientific and clinical community, and the general public. It is registered in the ClinicalTrials.gov database with the number NCT05430776.
BACKGROUND Infants born with a short lingual frenulum, a condition known as ankyloglossia or tongue-tie, can experience breastfeeding difficulties and often require surgical frenotomy to restore functional mobility. Topical anesthesia is commonly used to minimize discomfort during the procedure, and adverse reactions are rare. This case report describes a 48-day-old female infant who experienced an allergic reaction to topical anesthesia with tetracaine and phenylephrine during frenotomy. CASE REPORT A 48-day-old infant with ankyloglossia and breastfeeding difficulties was referred for specialized dental evaluation. Laser frenotomy was indicated and performed under topical anesthesia with tetracaine and phenylephrine, followed by infiltrative anesthesia with lidocaine. During the application of the topical anesthetic, the patient developed lip edema and vesicles, which led to a diagnosis of ophthalmic anesthetic-induced angioedema. The procedure was completed without further complications, and the patient showed progressive improvement of the allergic condition postoperatively. CONCLUSIONS This case report highlights a rare complication of topical anesthesia with tetracaine and phenylephrine during frenotomy in a 48-day-old infant with breastfeeding difficulties. The observed allergic reaction emphasizes the importance of caution when using medications outside their intended scope and underscores the need for careful monitoring of adverse effects during procedures.
Background/Objectives: In lingual frenectomy/frenotomy surgeries, thermal surgical instruments are commonly used because of their hemostatic effect, precise cutting, and lack of need for sutures. However, the effects of tissue heating on the biological repair process remain under investigation. This study aimed to evaluate the thermal and histological effects of a surgical lingual frenulum incisions performed with high-power diode lasers at 450 nm (blue) and 980 nm (infrared), compared with a surgical scissor incision (control group). Methods: The experimental project was conducted in two phases: first, an ex vivo experiment on porcine tongues using different surgical instruments, with different parameters, with thermal variations recorded using infrared thermography; and second, an in vivo phase using the instruments previously determined in the ex vivo phase. Results: Results demonstrated minimal tissue heating in the control group. There was a thermal elevation with the laser instruments, particularly with the 980 nm and 450 nm diode lasers; however, the 450 nm laser showed a high initial temperature increase, but exhibited faster tissue cooling. Thermal and histological analyses performed immediately after the procedure and on the seventh postoperative day showed clinically similar tissue repair across groups, with less disorganization of collagen fiber bundles on day seven in the group treated with the 450 nm laser. Conclusions: In conclusion, both diode lasers can be safely employed for lingual frenulum incision when appropriate parameters are used; however, further clinical studies are warranted to establish safe and effective parameters.