A technique suitable for diffusion tensor imaging (DTI) at high field strengths is presented in this work. The method is based on a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) k‐space trajectory using EPI as the signal readout module, and hence is dubbed PROPELLER EPI. The implementation of PROPELLER EPI included a series of correction schemes to reduce possible errors associated with the intrinsically higher sensitivity of EPI to off‐resonance effects. Experimental results on a 3.0 Tesla MR system showed that the PROPELLER EPI images exhibit substantially reduced geometric distortions compared with single‐shot EPI, at a much lower RF specific absorption rate (SAR) than the original version of the PROPELLER fast spin‐echo (FSE) technique. For DTI, the self‐navigated phase‐correction capability of the PROPELLER EPI sequence was shown to be effective for in vivo imaging. A higher signal‐to‐noise ratio (SNR) compared to single‐shot EPI at an identical total scan time was achieved, which is advantageous for routine DTI applications in clinical practice. Magn Reson Med, 2005.
18 March 2010 in American Journal of Neuroradiology
SUMMARY: There have been numerous reports documenting the graphic reconstruction of 3D white matter architecture in the human brain by means of diffusion tensor MR tractography. Different from other reviews addressing the physics and clinical applications of DTI, this article reviews the computational principles of tractography algorithms appearing in the literature. The simplest voxel-based method and 2 widely used subvoxel approaches are illustrated first, together with brief notes on parameter selection and the restrictions arising from the distinct attributes of tract estimations. Subsequently, some advanced techniques attempting to offer improvement in various aspects are briefly introduced, including the increasingly popular research tracking tool using HARDI. The article explains the inherent technical limitations in most of the algorithms reported to date and concludes by providing a reference guideline for formulating routine applications of this important tool to clinical neuroradiology in an objective and reproducible manner.
1 May 1995 in Journal of Bone and Mineral Research
A new approach for the quantitative analysis of trabecular microstructure, based on high-field proton nuclear magnetic resonance (NMR) imaging, is presented. NMR is ideal because it provides high contrast between the marrow proton signal and the bone, which appears with background intensity. Images from 1 cm3 defatted specimens of trabecular bone, suspended in water doped with 1 mM Gd(DTPA) to shorten T1 to about 300 ms, can be obtained at a resolution on the order of 30–50 μm and slice thickness of 150 μm, in 10 minutes at 400 MHz proton frequency. Digital image processing algorithms were designed and evaluated for the measurement of bone area fraction, perimeter length, mean trabecular thickness, and separation. Bone area fraction derived from the NMR images was found to be in excellent agreement with bone volume fraction measured independently (slope = 0.96, r2 = 0.924, p < 0.0001). Errors in the mean trabecular thickness and separation were <6%. The effects of finite imaging slice thickness and signal-to-noise ratio (SNR) were also evaluated. The data suggest a resolution of 50 × 50 × 200 μm3 and an SNR on the order of 10 to provide safe margins for precise and accurate structural analysis by means of the algorithms presented in this paper. The method allows simultaneous measurement at multiple locations within the specimen volume without the need for physical sectioning.
A method for objectively determining supratentorial cerebrospinal fluid (CSF) production rate is described. The method employs cine phase-contrast magnetic resonance imaging with high temporal and spatial resolution at the level of the aqueduct of Sylvius. Automatic encircling of the aqueduct was accomplished by using a pulsatility-based segmentation approach. Results in 23 healthy adults (18 men, five women; age range, 21-39 years) yielded an average CSF production rate of 305 microL/min +/- 145 (standard deviation); this rate is in good agreement with literature-reported values obtained with invasive ventriculolumbar perfusion measurements. Average operator imprecision was 23.1% if automatic segmentation was not used. The proposed method is potentially an effective means for measuring supratentorial CSF production rate in humans.
1 October 1995 in Journal of Bone and Mineral Research
The conventional approach to measuring structural parameters in trabecular bone rests on stereology from optical images, derived from sections of embedded bone. In order to provide data that are statistically representative of a sufficiently large volume, multiple sections need to be analyzed in each of the three orthogonal planes. In this work, an alternative technique is presented which is based on three-dimensional (3D) volumetric proton nuclear magnetic resonance (NMR) microimaging. The method presented provides images from 9 × 9 × 4 mm3 volumes of defatted bone specimens in 15–20 minutes scan time at isotropic resolution corresponding to (78 μm)3 voxel size. Surface-rendered images of bovine and human trabecular bone are shown and an algorithm was developed and implemented for determining the orientation and magnitude of the principal axes of the mean intercept length tensor.
13 November 2014 in Magnetic Resonance in Medicine