Alaeddin Acar

Dr. Alaeddin Acar

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2025 in JMIR Medical Informatics
Verified
Journal Article
Open access
AAAlaeddin Acar
Alaeddin Acar

13 January 2026 in Wiener Medizinische Wochenschrift
Verified
Journal Article
Closed access
PDF file
ATAbdullah Tozluyurt
Abdullah Tozluyurt
MSMustafa Sahin
Mustafa Sahin
AAAlaeddin Acar
Alaeddin Acar

17 March 2026 in JMIR Formative Research
Verified
Journal Article
Open access
OAOrhan Ayas
Orhan Ayas
AAAlaeddin Acar
Alaeddin Acar
We read with great interest the study by Anusitviwat et al [1], which compared the performance of ChatGPT and DeepSeek in orthopedic examinations. While the study provides timely insights into the utility of Large Language Models (LLMs) in medical education, we identified specific methodological and terminological limitations that warrant clarification to ensure the validity and reproducibility of the findings. Misinterpretation of Reliability Statistics The authors state that the "interrater reliability between the two LLMs" was evaluated using the Cohen κ coefficient [1]. Mathematically, measuring the agreement between two independent raters (inter-rater) yields a single coefficient. However, the results report two separate values: κ=0.81 for ChatGPT and κ=0.78 for DeepSeek [1]. This finding, combined with the methodology stating questions were input on "separate days [1], indicates that the study actually measured intra-model consistency (test-retest reliability) rather than the agreement between the models. Labeling internal consistency as "interrater reliability" is terminologically inaccurate and misrepresents the statistical relationship between the two models. Linguistic Ambiguity and Generalizability The manuscript does not specify the language of the input MCQs (Thai or English) used in the assessments. This omission is critical, as the impact of input language on LLM performance is well-documented. For instance, Noda et al (2024) [2] demonstrated that GPT-4V's accuracy on the Japanese Otolaryngology Board Examination significantly improved from 24.7% (Japanese input) to 47.3% when translated into English. This finding underscores that models optimized for English exhibit distinct performance disparities in non-English languages. Without clarifying whether the assessments were administered in the local language or English, it is impossible to determine if the reported accuracy gap between ChatGPT (80.4%) and DeepSeek (74.2%) stems from medical reasoning capabilities or linguistic processing proficiency. Reproducibility and Interface Transparency The methodology reports the use of "Reason" and "DeepThink" functions but does not explicitly state whether the models were accessed via Web User Interfaces (UI) or Application Programming Interfaces (API) [1]. This distinction is vital for reproducibility. Web UIs are subject to opaque updates and lack the stability of controlled API environments. Without defining the access method and the specific prompt structures used, the experimental conditions cannot be replicated. Risk of Data Contamination The authors note that the MCQs "have been used in orthopedic examinations for more than 5 years". This longevity significantly increases the risk of data contamination, as older items likely exist in public repositories within LLM training corpora, potentially conflating memorization with reasoning. To ensure validity, recent benchmarks employ private datasets (Busch et al [3]) or questions post-dating the model’s training cut-off (Noda et al [2]). The absence of such controls in this study undermines the internal validity of the comparison Data Reporting Discrepancy Finally, we noted a minor discrepancy in Table 2. In the "Pelvic and spine injury" category (n=19), the accuracy for the Reason function is listed as 16 (68.8%) [1]. Mathematically, 16 out of 19 corresponds to approximately 84.2%, not 68.8%. We respectfully invite the authors to clarify this value to ensure the precision of the tabulated data.

28 January 2026 in JMIR Research Protocols
Verified
Journal Article
Open access
AAAlaeddin Acar
Alaeddin Acar
DYDiaa Yahya
Diaa Yahya
ETEray Tekirdaş
Eray Tekirdaş

20 July 2025 in JMIR Preprints
Verified
Preprint
Open access
AAAlaeddin Acar
Alaeddin Acar
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

6 March 2026 in JMIR Preprints
Verified
Preprint
Open access
SASema Nur Acar
Sema Nur Acar
AAAlaeddin Acar
Alaeddin Acar
UNSTRUCTURED We read with interest the protocol by Khanadali and Ikhar [1] evaluating cerium oxide nanoparticles (CeO₂-NPs) and chlorhexidine gluconate (CHX) against Enterococcus faecalis in root canals. We identified critical concerns regarding vehicle formulation and outcome assessment. The fundamental issue lies in inconsistent vehicle formulation. Groups 2 (CeO₂-NPs) and 3 (CeO₂-NPs + CHX) contain methyl cellulose as a thickening agent, producing gel-like consistency, whereas the negative control (Group 4) is sterile water without this excipient. Consequently, any observed CFU reduction in the nanoparticle groups cannot be unambiguously attributed to CeO₂-NPs, as the gel matrix itself may contribute to the antimicrobial outcome. Methyl cellulose forms a viscous hydrogel matrix that coats biofilms, restricts oxygen and nutrient diffusion, and alters agent–dentin contact dynamics. If Groups 2 or 3 demonstrate superior bacterial reduction, it becomes impossible to distinguish whether this stems from the intrinsic antimicrobial activity of CeO₂-NPs or from the physical barrier effect of the methyl cellulose matrix itself. A second concern is the absence of outcome assessor blinding. The protocol specifies CFU counts "manually or using a digital colony counter," yet no blinding of the evaluator to group allocation is described [2]. The use of vehicle controls is well established in endodontic research. Tagelsir et al [3], evaluating antimicrobials against a 3-week-old E. faecalis biofilm, included a placebo paste (methylcellulose only) as the vehicle control—thereby isolating the physical effects of the gel matrix from the antimicrobial activity of the test agents. We recommend the same approach here: Group 4 should be reformulated as a vehicle control (sterile water + methyl cellulose) rather than sterile water alone, so that the physical effects of the gel matrix can be isolated from the antimicrobial activity of CeO₂-NPs in Groups 2 and 3. Additionally, CFU assessment should be performed by a blinded evaluator. We respectfully encourage the authors to consider these modifications, which would strengthen the study's internal validity and the interpretability of its anticipated findings.