Fernando Henrique Cardoso

Mr. Fernando Henrique Cardoso

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
Mauricio Martins DonattiMauricio Martins Donatti
Mauricio Martins Donatti
FCFernando Henrique Cardoso
Fernando Henrique Cardoso
LTLucas Tanio
Lucas Tanio
In synchrotron light source applications, the photon beam interaction with various materials can produce electric charge which can be measured as current and be used to diagnose particle trajectories, beam intensity, beam profile, position, and stability. Sirius, a 4th-generation Brazilian synchrotron light source, will make use of hundreds of low-intensity measurement instruments. This work aims to show and discuss the design details, challenges, and test results of an Ethernet four-channel high-performance digital ammeter, applied for general-purpose beam diagnostics. The device is based on low-noise and extremely low input bias bipolar transimpedance amplifiers with eight selectable ranges (full scales from pA to mA). Characterization results show that the achieved gain, accuracy, and noise performance are on the same order of magnitude as those of expensive commercial benchtop equipment. In low bandwidth applications, the device was able to measure amplitudes of hundreds of picoampere with intrinsic noise of units of femtoampere (RMS). The designed device is a cost-effective solution.

9 June 2026 in Instruments
Verified
Journal Article
Open access
PDF file
LTLucas Tanio
Lucas Tanio
Mauricio Martins DonattiMauricio Martins Donatti
Mauricio Martins Donatti
FCFernando Henrique Cardoso
Fernando Henrique Cardoso
Patrícia NallinPatrícia Nallin
Patrícia Nallin
VOVinicius Oliveira
Vinicius Oliveira
APAline Ribeiro Passos
Aline Ribeiro Passos
To address the high demand for precise low-current measurements at the Sirius’ beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed. The instrument can measure currents ranging from femtoampere to milliampere across eight selectable ranges, featuring integrated analog-to-digital converters (ADCs), enabling sampling rates of up to 2 ksps and synchronization capabilities. This work describes the hardware design, the hardware handling procedures to achieve sub-picoampere resolution, and the characterization results of the instrument, considering the experimental results from Sirius beamlines. The designed device provides noise performance and gain accuracy that is comparable to high-end commercial solutions, proving its suitability for critical applications like on-the-fly scanning experiments. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines. Furthermore, we will deeply explore the interplay between the trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize the signal-to-noise ratio in specific applications. The hardware project is publicly available in CERN’s open hardware repository.

1 December 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
ABAllan Borgato
Allan Borgato
AGAugusto Fraga Giachero
Augusto Fraga Giachero
DTDaniel de Oliveira Tavares
Daniel de Oliveira Tavares
EAErick Battiston Antonio
Erick Battiston Antonio
FCFernando Henrique Cardoso
Fernando Henrique Cardoso
TCThiago Paiva Costa
Thiago Paiva Costa
TUPI (Timepix4-based Ultra-fast Photon Imaging) is the new family of direct conversion and vacuum-compatible hybrid detectors under design at Sirius, the Brazilian 4th generation light source. Based on the Timepix4 Application Specific Integrated Circuit (ASIC), it targets different kinds of experiments, such as tomography and spectrometry, and will be used in multiple bioimaging beamlines of Orion, Brazil's Biosafety Level 4 (BSL4) Laboratory project. Also, it will cover a wide energy range (5 to 45 keV) by using different sensors materials (Si, GaAs, CdTe, etc.). Designed in a modular approach to ensure scalability for constructing larger active areas in a compact form, each TUPI module will be composed by a set of 3x side-by-side Timepix4 ASICs to provide a sensitive area of approximately 74×28 mm2 (1344×512 pixels of 55 μm pitch), streaming up to 44 kfps through up to 48×10.24 Gbps optical links directly connected to a Data Acquisition (DAQ) system.