Janis Dröge

Mr. Janis Dröge


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
NZNicole Zulauf
Nicole Zulauf
JDJanis Dröge
Janis Dröge
DKDoris Klingelhöfer
Doris Klingelhöfer
MBMarkus Braun
Markus Braun
GOGerhard M. Oremek
Gerhard M. Oremek
David GronebergDavid Groneberg
David Groneberg
From a global viewpoint, a lot of time is spent within the indoor air compartment of vehicles. A German study on mobility has revealed that, on average, people spend 45 minutes per day inside vehicles. In recent years the number of cars has increased to around 43 million vehicles in private households. This means that more than one car can be used in every household. The ratio has been growing, especially in eastern Germany and rural areas. “Overall and especially outside the cities, the car remains by far number one mode of transport, especially in terms of mileage”. Therefore, numerous international studies have addressed different aspects of indoor air hygiene, in the past years. In this paper, meaningful original studies on car indoor air pollution, related to VOCs, COx, PMs, microbials, BFRs, OPFRs, cigarettes, electronic smoking devices, high molecular weight plasticizer, and NOx are summarized in the form of a review. This present review aimed to summarize recently published studies in this important field of environmental medicine and points to the need for further studies with special recommendations for optimizing the interior air hygiene.

JDJanis Dröge
Janis Dröge
RMRuth Müller
Ruth Müller
CSCristian Scutaru
Cristian Scutaru
MBMarkus Braun
Markus Braun
David GronebergDavid Groneberg
David Groneberg
Air pollution of particulate matter (PM) from traffic emissions has a significant impact on human health. Risk assessments for different traffic participants are often performed on the basis of data from local air quality monitoring stations. Numerous studies demonstrated the limitation of this approach. To assess the risk of PM exposure to a car driver more realistically, we measure the exposure to PM in a car cabin with a mobile aerosol spectrometer in Frankfurt am Main under different settings (local variations, opened versus a closed window) and compare it with data from stationary measurement. A video camera monitored the surroundings for potential PM source detection. In-cabin concentrations peaked at 508 µg m−3 for PM10, 133.9 µg m−3 for PM2.5, and 401.3 µg m−3 for coarse particles, and strongly depended on PM size and PM concentration in ambient air. The concentration of smaller particles showed low fluctuations, but the concentration of coarse particles showed high fluctuations with maximum values on busy roads. Several of these concentration peaks were assigned to the corresponding sources with characteristic particle size distribution profiles. The closure of the car window reduced the exposure to PM, and in particular to coarse particles. The mobile measured PM values differed significantly from stationary PM measures, although good correlations were computed for finer particles. Mobile rather than stationary measurements are essential to assess the risk of PM exposure for car passengers.

1 February 2024 in Environmental Pollution
Verified
Journal Article
Open access
JDJanis Dröge
Janis Dröge
DKDoris Klingelhoefer
Doris Klingelhoefer
MBMarkus Braun
Markus Braun
David GronebergDavid Groneberg
David Groneberg
Exposure to ultrafine particles has a significant influence on human health. In regions with large commercial airports, air traffic and ground operations can represent a potential particle source. The particle number concentration was measured in a low-traffic residential area about 7 km from Frankfurt Airport with a Condensation Particle Counter in a long-term study. In addition, the particle number size distribution was determined using a Fast Mobility Particle Sizer. The particle number concentrations showed high variations over the entire measuring period and even within a single day. A maximum 24 h-mean of 24,120 cm-3 was detected. Very high particle number concentrations were in particular measured when the wind came from the direction of the airport. In this case, the particle number size distribution showed a maximum in the particle size range between 5 and 15 nm. Particles produced by combustion in jet engines typically have this size range and a high potential to be deposited in the alveoli. During a period with high air traffic volume, significantly higher particle number concentrations could be measured than during a period with low air traffic volume, as in the COVID-19 pandemic. A large commercial airport thus has the potential to lead to a high particle number concentration even in a distant residential area. Due to the high particle number concentrations, the critical particle size, and strong concentration fluctuations, long-term measurements are essential for a realistic exposure analysis.

24 August 2022 in Journal of Occupational Medicine and Toxicology
Verified
Journal Article
Open access
PDF file
LPLukas Pitten
Lukas Pitten
DBDörthe Brüggmann
Dörthe Brüggmann
JDJanis Dröge
Janis Dröge
MBMarkus Braun
Markus Braun
David GronebergDavid Groneberg
David Groneberg
Background: Particulate matter (PM) emission caused by tobacco combustion leads to severe health burdens worldwide. Second-hand smoke exposure is extraordinarily high in enclosed spaces (e.g., indoor rooms, car cabins) and poses a particular threat to the health of vulnerable individuals (e.g., children, elderly, etc.). This study aimed to establish a new measuring platform and investigate PM emissions under four different ventilation conditions inside a car cabin without exposing any person to harmful tobacco smoke. Methods: PM concentrations were measured during the smoking of 3R4F reference cigarettes in a Mitsubishi Space Runner (interior volume 3.709 m3). The cigarettes were smoked with a machine, eliminating exposure of the researchers. Cigarettes were extinguished 4.5 min after ignition, and PM measurements continued until 10 min after ignition. Results: High mean PM concentrations were measured for cigarettes without ventilation after 4.5 min (PM10: 1150 µg/m3, PM2.5: 1132 µg/m3, PM1: 861.6 µg/m3) and after 10 min (PM10: 1608 µg/m3, PM2.5: 1583 µg/m3, PM1: 1133 µg/m3). 3R4F smoked under conditions with turned on ventilation resulted in reduction of PM compared to those smoked without ventilation after 4.5 min (PM10:-47.5 to -58.4%, PM2.5:-47.2 to -58%, PM1:-39.6 to -50.2%) and after 10 min (PM10:-70.8 to -74.4%, PM2.5:-70.6 to -74.3%, PM1:-64.0 to -68.0%). Cigarettes smoked without ventilation generated high PM peaks at 4.5 min (PM10: 2207 µg/m3, PM2.5: 2166 µg/m3, PM1: 1421 µg/m3) and at 10 min (PM10: 1989 µg/m3, PM2.5: 1959 µg/m3, PM1: 1375 µg/m3). PM peaks of cigarettes smoked under different ventilation modes varied at 4.5 min (PM10: 630-845 µg/m3, PM2.5: 625-836 µg/m3, PM1: 543 - 693 µg/m3) and 10 min (PM10: 124 - 130 µg/m3, PM2.5: 124 - 129 µg/m3, PM1: 118 - 124 µg/m3). Conclusion: The new measuring platform provides a safer way for researchers to investigate PM emissions of cigarettes. These data are comparable to published research and show that smoking in a parked vehicle with the windows closed generates harmful PM emissions even when the vehicle ventilation is in operation. Future studies should be carried out using the new measuring platform investigating PM exposure and PM distribution of in-vehicle smoking under a wide range of conditions.

14 April 2022 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
JDJanis Dröge
Janis Dröge
IMIbrahim El Moussaoui
Ibrahim El Moussaoui
DKDoris Klingelhöfer
Doris Klingelhöfer
HHHannelore Held
Hannelore Held
DGDavid. A. Groneberg
David. A. Groneberg
SPStefanie Plenzig
Stefanie Plenzig
Particulate matter emitted during autopsies can serve as a vector for numerous viruses or bacteria and can lead to infections. Reducing the exposure of those particles in indoor working environments is, therefore, an important issue. To assess the health risk for employees in forensic medicine, we measure particulate matter in the ambient air during autopsies by using an aerosol spectrometer. The autopsies were performed with either an ordinary oscillating saw or an adapted saw with a suction unit. The particle emissions from both saws were compared to each other in order to evaluate whether a technical adaption leads to a particle reduction. Furthermore, the particle exposure reduction by wearing a face mask and variations in the background concentration in the room were analyzed. High particle concentrations were measured while using the ordinary saw. By using the adapted saw or wearing a face mask, the particle exposure could mostly be avoided. On the majority of the working days, an increase in the background concentration could be observed. Based on this knowledge, the use of a proper suction unit and wearing a face mask during autopsies is necessary. Besides, it is important to have sufficient ventilation in the room so that long-lasting high background concentrations can be prevented. Graphical abstract

13 February 2019 in Zentralblatt für Arbeitsmedizin, Arbeitsschutz und Ergonomie
Verified
Journal Article
Closed access
PDF file
NZNicole Zulauf
Nicole Zulauf
GOG. M. Oremek
G. M. Oremek
MBMarkus Braun
Markus Braun
JDJanis Dröge
Janis Dröge
DQD. Quarcoo
D. Quarcoo