Theoretical and experimental modal analyses are treated for hydraulic systems modeled by discrete capacities, inductances, resistances, and fluid lines with dynamic laminar flow. Based on an approximate multi-degrees-of-freedom description, it is shown how hydraulic natural frequencies, damping ratios, and mode shapes can be identified from measured frequency response functions between flow rate excitation and pressure response. Experiments are presented for a pipeline system that includes three side branches and an accumulator. In view of practical applications, two different types of servovalve excitation as well as impact hammer excitation are considered. Pressure is measured by 19 sensors throughout the system. Results are compared in terms of frequency response functions between 50 and 850 Hz, the first five hydraulic modes, and weighted auto modal assurance criteria of experimental mode shapes. Out of the tested excitation devices, the servovalve is clearly preferred; if valves cannot be used, the impact hammer offers a reasonable workaround. For a reduced number of five sensors, different sensor arrangements are assessed by the respective weighted auto modal assurance criteria of experimental mode shapes. A theoretical hydraulic modal model provides a similar assessment. The quality of the theoretical model is confirmed by the weighted modal assurance criterion of theoretical and experimental mode shapes from servovalve excitation.
23 August 2017 in International Journal of Fluid Power
This paper presents a mechanical compensator for hydraulic pressure pulsations induced by a pump or motor. The compensator is based on the combination of pump or motor mass moment of inertia and the torsional compliance of the adjacent coupling. According to the displacement volume, angular deflections of the resulting oscillator correspond to volumes which can compensate for geometric or dynamic pulsations at the natural frequency of the oscillator. Two design concepts are suggested for the coupling. Three models are set up for various configurations of the overall system, accounting for limited inertia of an electric motor and the influence of an outlet pipeline. Model parameters are determined for a 32 ccm radial piston pump and a 250 ccm axial piston pump. Torsional damping from viscous friction is roughly estimated and considered by different levels. At the pump outlet, frequency response functions between flow rate excitation and pressure response are calculated. The results show that the compensation effect is relevant for both pumps and particularly robust with respect to resonances in the hydraulic system.
Pressure pulsations generated by pumps impair noise behaviour, increase mechanical loading, and reduce control performance in hydraulic systems. This study investigates the use of a rotary mechanical pulsation compensator integrated into the drivetrain of an external gear pump. The aim is to attenuate pulsations directly at their source without modifying the hydraulic layout. This is accomplished by using the torque induced flow rate pulsation to cancel the external flow rate excitation, which leads to destructive interference between flow rate induced and torque induced pressure pulsations. An analytical frequency domain model of the coupled mechanical–hydraulic system is derived to determine the required stiffness and damping conditions. The theoretical results are validated experimentally at mean pressure levels of 100 bar and 170 bar, both for two different hydraulic layouts. With a resonator pipeline at the pump outlet, the first harmonic of the pressure pulsation at the compensation frequency is reduced by 10.9 bar and 18.4 bar, respectively, which corresponds to reduction rates of 93% and 98%. The required damping value depends on the operating conditions, but it is independent of the hydraulic layout. While insufficient damping increases pressure pulsations around the compensation frequency, slightly higher damping flattens the frequency characteristics of pressure pulsation and reduces the maxima around the compensation frequency. In the neighbourhood of this frequency, the proposed concept enables effective reduction of the first pressure pulsation harmonic through a structural modification of the drivetrain.