Irritable bowel syndrome (IBS) is a widespread functional disorder of the digestive tract. Its aetiology is unknown and therapeutic options are limited. Recent reports suggest that probiotics may have a role in regulating the motility of the digestive tract. To assess the efficacy of Lactobacillus plantarum 299V (LP299V) in patients with IBS. Forty patients were randomized to receive either LP299V in liquid suspension (20 patients) or placebo (20 patients) over a period of 4 weeks. Clinical examination was performed at baseline and at the end of the study. Additionally, patients assessed their symptoms by applying a scoring system. All patients treated with LP299V reported resolution of their abdominal pain as compared to 11 patients from a placebo group (P = 0.0012). There was also a trend towards normalization of stools frequency in constipated patients in six out of 10 patients treated with LP299V compared with two out of 11 treated with placebo (P = 0.17). With regards to all IBS symptoms an improvement was noted in 95% of patients in the LP299V group vs 15% of patients in the placebo group (P < 0.0001). LP299V seems to have a beneficial effect in patients with IBS. Further studies on larger cohorts of patients and with longer duration of therapy are required in order to establish the place of L. plantarum in the treatment of IBS.
99mTc-hydrazinonicotinamide-Tyr3-octreotide (99mTc-HYNIC-TOC) is increasingly gaining acceptance as a new radiopharmaceutical for the diagnosis of pathologic lesions overexpressing somatostatin receptors. However, little information has been published about the radiation dosimetry of this agent. The aim of this study was to assess the biodistribution and radiation dosimetry of commercially available 99mTc-HYNIC-TOC. A dose calculation procedure designed to be feasible to implement in a busy clinical environment was used. Methods: Twenty-eight patients were imaged for suspected neuroendocrine tumors using a series of whole-body planar, dynamic planar, and SPECT/CT studies, after injection with 99mTc-HYNIC-TOC. Patient-specific dosimetry was performed using the OLINDA/EXM software with time-integrated activity coefficients estimated from a hybrid planar/SPECT technique. A phantom experiment was performed to establish adaptive thresholds for determination of source region volumes and activities. Results: Pathologic uptake, diagnosed as due to neuroendocrine tumors, was observed in 12 patients. Normal organs with significant uptake included the kidneys, liver, and spleen. The mean effective dose after 99mTc-HYNIC-TOC injection was 4.6 ± 1.1 mSv. Average normal-organ doses were 0.030 ± 0.012, 0.021 ± 0.007, and 0.012 ± 0.005 mGy/MBq for the spleen, kidneys, and liver, respectively. The interpatient kidney dose ranged from 0.011 to 0.039 mGy/MBq, whereas the range of tumor doses varied from 0.003 to 0.053 mGy/MBq. The ratio of tumor to kidney dose ranged from 0.13 to 2.9. The optimal thresholds for recovery of true activity in the phantom study were significantly lower than those used for volume determination. Conclusion: The patient-specific 3-dimensional dosimetry protocol used in this study is a clinically feasible technique that has been applied to demonstrate large dose variations in tumors and normal organs between patients imaged with 99mTc-HYNIC-TOC.
Selective IgA deficiency (sIgAD) is the most common primary immunodeficiency disease (PID), with an estimated occurrence from about 1:3000 to even 1:150, depending on population. sIgAD is diagnosed in adults and children after the 4th year of age, with immunoglobulin A level below 0.07 g/L and normal levels of IgM and IgG. Usually, the disease remains undiagnosed throughout the patient’s life, due to its frequent asymptomatic course. If symptomatic, sIgAD is connected to more frequent viral and bacterial infections of upper respiratory, urinary, and gastrointestinal tracts, as well as autoimmune and allergic diseases. Interestingly, it may also be associated with other PIDs, such as IgG subclasses deficiency or specific antibodies deficiency. Rarely sIgAD can evolve to common variable immunodeficiency disease (CVID). It should also be remembered that IgA deficiency may occur in the course of other conditions or result from their treatment. It is hypothesized that allergic diseases (e.g., eczema, rhinitis, asthma) are more common in patients diagnosed with this particular PID. Selective IgA deficiency, although usually mildly symptomatic, can be difficult for clinicians. The aim of the study is to summarize the connection between selective IgA deficiency and atopic diseases.
1 December 2012 in Nuclear Medicine Communications
Objective Our aim was to design a practical and reproducible image segmentation method for calculations of total absorbed doses in organs and tumours for internally delivered radioisotopes. We have built upon our previously proposed use of two separate thresholds and employed an iterative technique for semiautomatic selection of background regions for segmenting an object of interest using thresholds that depend on the source-to-background ratio of activity concentrations. Methods The parameters of curves relating volume and activity thresholds to source-to-background ratio were established using phantoms with 20 different inserts. The accuracy of our technique was validated using a second phantom experiment, whereas the reproducibility of volume, activity and dose estimates of organs and tumours was investigated using 13 patient studies. The accuracy and reproducibility of segmentations achieved were assessed using images reconstructed with three different methods that ranged from a standard clinical reconstruction to an advanced quantitative reconstruction approach. Results In the validation phantom experiment, bottle volumes and activities measured using iterative adaptive thresholding agreed on average with the true values to within 4%, regardless of the reconstruction method used. In the patient studies, volumes and activities estimated from the single-photon emission computed tomography images reconstructed with clinical software agreed with the volumes and activities estimated using the advanced reconstruction approach to within 6%, whereas the corresponding doses agreed to within 4%. Conclusion The proposed iterative adaptive thresholding technique can accurately determine object volume and activity, which allows standard clinical reconstructions to generate absorbed dose estimates that are similar to those values obtained using more advanced reconstruction methods.
We investigated the quantitative accuracy of SPECT/CT imaging studies as would be performed before and after targeted radionuclide therapy (TRT) using phantom experiments with (i) (99m)Tc, (ii) ¹⁷⁷Lu and (iii) ⁹⁰Y/¹⁷⁷Lu. While the experiment with (99m)Tc imitated a diagnostic scan, the experiments with ¹⁷⁷Lu and ⁹⁰Y/¹⁷⁷Lu modeled post-therapy acquisitions. At the next stage, we reconstructed images from pre- and post-therapy patient studies. The data were first reconstructed using two methods with limited corrections for the physics effects. Then, to generate quantitatively accurate absolute activity distributions, we applied a hybrid (model-based and window-based) reconstruction strategy where some of the physics effects were accurately modeled while corrections for other effects were empirical and based on information obtained from the projection data. The accuracies of absolute activity recovered by the hybrid method from the six phantom experiments were very similar to each other and acceptable for potential use in TRT. When measured in identical regions of interest, the (99m)Tc ⁹⁰activity was reconstructed with errors ranging between -3.3% and 2.9%, while the ¹⁷⁷Lu activity was reconstructed from experiments with ¹⁷⁷Lu and Y/¹⁷⁷Lu with errors ranging between -1.6% and 1.6%. The reconstruction algorithms with limited corrections led to larger and case-specific errors as might have been expected. From a clinical prospective, our results showed that physics-based reconstructions improved resolution of images corresponding to both diagnostic scans with (99m)Tc and post-therapy scans with ¹⁷⁷Lu. Our analysis of patient study demonstrated that lack of corrections led to overestimation of activities in organs and tumor by 29-39% for the diagnostic scan with (99m)Tc and by 105-218% for post-therapy scan with ¹⁷⁷Lu.