Zheng Wang

Prof. Zheng Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in JMIR Formative Research
Verified
Journal Article
Open access
ZWZheng Wang
Zheng Wang
JKJohn Kempen
John Kempen
GLGang Luo
Gang Luo
Background: While it is treatable, uncorrected refractive error is the number one cause of visual impairment worldwide. This eye condition alone, or together with ocular misalignment, can also cause amblyopia, which is also treatable if detected early but still occurs in about 4% of the population. Mass vision screening is the first and most critical step to address these issues, but due to limited resources, vision screening in many rural areas remains a major challenge. Objective: We aimed to pilot-test the feasibility of using smartphone apps to enhance vision screening in areas where access to eye care is limited. Methods: A vision screening program was piggybacked on a charity summer camp program in a rural county in Sichuan, China. A total of 73 fourth and fifth graders were tested for visual acuity using a standard eye chart and were then tested for refractive error and heterophoria using 2 smartphone apps (a refraction app and a strabismus app, respectively) by nonprofessional personnel. Results: A total of 5 of 73 (6.8%, 95% CI 2.3%-15.3%) students were found to have visual acuity worse than 20/20 (logarithm of minimal angle of resolution [logMAR] 0) in at least one eye. Among the 5 students, 3 primarily had refractive error according to the refraction app. The other 2 students had manifest strabismus (one with 72–prism diopter [PD] esotropia and one with 33-PD exotropia) according to the strabismus app. Students without manifest strabismus were also measured for phoria using the strabismus app in cover/uncover mode. The median phoria was 0.0-PD (IQR 2.9-PD esophoria to 2.2-PD exophoria). Conclusions: The results from this vision screening study are consistent with findings from other population-based vision screening studies in which conventional tools were used by ophthalmic professionals. The smartphone apps are promising and have the potential to be used in mass vision screenings for identifying risk factors for amblyopia and for myopia control. The smartphone apps may have significant implications for the future of low-cost vision care, particularly in resource-constrained and geographically remote areas.

4 November 2025 in JMIR Formative Research
Verified
Journal Article
Open access
JHJunxian He
Junxian He
JZJiawei Zhang
Jiawei Zhang
ZWZheng Wang
Zheng Wang
SPShrinivas Pundlik
Shrinivas Pundlik
RLRui Liu
Rui Liu
GLGang Luo
Gang Luo
Background: Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. Objective: This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. Methods: The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. Results: In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. Conclusions: The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.

18 October 2024 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
GLGang Luo
Gang Luo
CLChen-Yuan Lee
Chen-Yuan Lee
ZWZheng Wang
Zheng Wang
PSPreana Shivshanker
Preana Shivshanker
YJYan Jiang
Yan Jiang
SPShrinivas Pundlik
Shrinivas Pundlik
To improve access to vision care and to enable mass vision screening, a smartphone app has been developed to measure refractive errors. Without needing any external attachment, the app running on a standalone phone can be used by lay personnel to measure subjective refraction. Its validity has been pilot-tested in clinical settings and underserved communities. The app estimates the refractive error by measuring the distances of far points for discerning visual stimuli. Spherical equivalent refraction and astigmatism can be measured using Tumbling E letters and grating patterns, respectively. The purpose of this paper is to describe the measurement protocols for performing subjective refraction using the app. Experimental results with 34 subjects (30 eyes for spherical equivalent and 38 eyes for astigmatism assessment) are presented. Measurement with the app was compared with standard clinical methods. The average absolute error of spherical equivalent refraction was 0.63D, and the average absolute error of astigmatism measurement was 0.28D. In addition, 22 subjects were enrolled to evaluate inter-pupillary distance (IPD) measurement with the app. The average absolute error in IPD measurement with the app was 1.2 mm. The protocol for measuring IPD with the app is also described.

19 June 2025 in JMIR Preprints
Verified
Preprint
Open access
JHJunxian He
Junxian He
JZJiawei Zhang
Jiawei Zhang
ZWZheng Wang
Zheng Wang
SPShrinivas Pundlik
Shrinivas Pundlik
RLRui Liu
Rui Liu
GLGang Luo
Gang Luo
BACKGROUND Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. OBJECTIVE This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. METHODS The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. RESULTS In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. CONCLUSIONS The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.

25 August 2026 in Strabismus
Verified
Journal Article
Closed access
THTingnan Huang
Tingnan Huang
LYLu Yu
Lu Yu
PCPei Chen
Pei Chen
YQYimeng Qu
Yimeng Qu
HYHuijie Yang
Huijie Yang
ZWZheng Wang
Zheng Wang
Strabismus, a condition characterized by the inability of both eyes to simultaneously focus on a target, is categorized clinically into horizontal, vertical, rotational, and mixed types based on th...

7 December 2023 in JMIR Preprints
Verified
Preprint
Open access
ZWZheng Wang
Zheng Wang
JKJohn Kempen
John Kempen
GLGang Luo
Gang Luo
BACKGROUND While it is treatable, uncorrected refractive error is the number one cause of visual impairment worldwide. This eye condition alone, or together with ocular misalignment, can also cause amblyopia, which is also treatable if detected early but still occurs in about 4% of the population. Mass vision screening is the first and most critical step to address these issues, but due to limited resources, vision screening in many rural areas remains a major challenge. OBJECTIVE We aimed to pilot-test the feasibility of using smartphone apps to enhance vision screening in areas where access to eye care is limited. METHODS A vision screening program was piggybacked on a charity summer camp program in a rural county in Sichuan, China. A total of 73 fourth and fifth graders were tested for visual acuity using a standard eye chart and were then tested for refractive error and heterophoria using 2 smartphone apps (a refraction app and a strabismus app, respectively) by nonprofessional personnel. RESULTS A total of 5 of 73 (6.8%, 95% CI 2.3%-15.3%) students were found to have visual acuity worse than 20/20 (logarithm of minimal angle of resolution [logMAR] 0) in at least one eye. Among the 5 students, 3 primarily had refractive error according to the refraction app. The other 2 students had manifest strabismus (one with 72–prism diopter [PD] esotropia and one with 33-PD exotropia) according to the strabismus app. Students without manifest strabismus were also measured for phoria using the strabismus app in cover/uncover mode. The median phoria was 0.0-PD (IQR 2.9-PD esophoria to 2.2-PD exophoria). CONCLUSIONS The results from this vision screening study are consistent with findings from other population-based vision screening studies in which conventional tools were used by ophthalmic professionals. The smartphone apps are promising and have the potential to be used in mass vision screenings for identifying risk factors for amblyopia and for myopia control. The smartphone apps may have significant implications for the future of low-cost vision care, particularly in resource-constrained and geographically remote areas.