Emre Cetin

Mr. Emre Cetin

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ECEmre Cetin
Emre Cetin
ADAliye Kartal Dogan
Aliye Kartal Dogan
ACAnil Cetinkaya
Anil Cetinkaya
EDErkan DANACI
Erkan DANACI
The reflection coefficient measurement of the RF signal generator output is clear when the signal generator output is turned off, as no interfering signal is present. However, measuring the reflection coefficient while the signal generator output is turned on creates complexity, as the generator’s output power can interfere with the reflected signal. A vector network analyzer (VNA) is the reference instrument for measuring the reflection coefficient, capturing both the magnitude and phase of scattering parameters. For measuring the active output of a signal generator, the signals created by the generator and the VNA must be isolated to prevent signal mixing and interference. This paper proposes a unique method to measure the output reflection coefficient of an RF signal generator when the output is on, using a VNA configured for one port reflection coefficient measurement. The method involves tuning the VNA receiver to a frequency slightly offset to the generator’s output. Simultaneously, selecting a narrow intermediate frequency bandwidth (IFBW) reduces the receiver’s noise floor and also eliminates out-of-band interference. As a result, the VNA and the generator operate in different frequency bands to avoid interferences between them, enabling accurate magnitude and phase measurements. To automate the process, a Windows-based software has been developed. This software automates the measurement sequence, controls generator power levels and VNA sweep parameters, captures both the magnitude and phase of the reflection coefficient, and records the result data. It also supports measurement at different output power levels, enabling characterization across a wide range of operating conditions.

6 July 2026 in Metrology
Verified
Journal Article
Open access
PDF file
ACAnil Cetinkaya
Anil Cetinkaya
ADAliye Kartal Dogan
Aliye Kartal Dogan
EDErkan DANACI
Erkan DANACI
Martin HudličkaMartin Hudlička
Martin Hudlička
JGJan Grajciar
Jan Grajciar
HOHalit Oğuztüzün
Halit Oğuztüzün
An interlaboratory comparison of RF power measurements using automatic power measurement software was carried out among partners of the European Partnership on Metrology project titled “Development of RF and microwave metrology capability II” (RFMicrowave2). The absolute RF power output of a travelling signal generator was measured at six frequencies between 2 GHz and 18 GHz and at three nominal power levels of −10 dBm, 0 dBm, and 10 dBm. Comparison results were evaluated in terms of comparison reference values, degrees of equivalence, and normalised errors. Uncertainty evaluations were performed using both the Guide to the Expression of Uncertainty in Measurement and Monte Carlo simulation methods. The results demonstrate an acceptable level of agreement among participating laboratories and confirm the applicability of automatic power measurement software for interlaboratory RF power comparisons.